{"id":{"repo_id":"star-france","oai_identifier":"2016LORR0136"},"canonical_url":"https://search.ndltd.org/etd/star-france/2016LORR0136","repository":{"repo_id":"star-france","name":"STAR","base_url":"https://staroai.theses.fr/OAIHandler"},"display":{"title":"Optimisation et réduction de la dose d’irradiation au scanner : aspects techniques et impact en pratique clinique courante","abstract":"Depuis son introduction dans les années 1970, le scanner est devenu une technique d’imagerie médicale incontournable grâce à son excellente performance pour le diagnostic de nombreuses pathologies. Toutefois, le scanner est un examen d’imagerie irradiant. Compte-tenu des risques potentiels de cancer radio-induit liés aux faibles doses de rayons X, la réduction de la dose d’irradiation au scanner est primordiale. Dans ce travail, nous avons étudié plusieurs facteurs techniques et comportementaux qui permettent d’optimiser et de réduire la dose d’irradiation au scanner, tout en préservant une excellente performance diagnostique. Du côté des facteurs comportementaux, la sensibilisation des équipes médicales et paramédicales est fondamentale dans une démarche d’optimisation de la dose d’irradiation au scanner. De même, la limitation du nombre de phases d’acquisition et la réduction de la couverture d’acquisition sont deux manières simples pour réduire les doses délivrées. Du côté des facteurs techniques, nous avons montrés que l’utilisation des reconstructions itératives, par rapport aux reconstructions standards en rétroprojection filtrée, permet de réduire de moitié la dose d’irradiation des scanners, à qualité d’image équivalente. L’acquisition en mode volumique pour les scanners avec une faible couverture d’acquisition et l’utilisation de la modulation automatique du milliampérage permettent aussi de réduire et d’optimiser les doses. Enfin, nous nous sommes intéressés à l’optimisation de protocoles de scanner en pratique clinique courante en se focalisant sur les scanners réalisés pour la recherche d’une colique néphrétique et pour les scanners en imagerie ostéo-articulaire. Dans ce dernier domaine, nous avons aussi proposé des protocoles de scanner pour des applications cliniques avancées comme le scanner dynamique des articulations ou le scanner de perfusion tumorale","abstract_html":"Depuis son introduction dans les années 1970, le scanner est devenu une technique d’imagerie médicale incontournable grâce à son excellente performance pour le diagnostic de nombreuses pathologies. Toutefois, le scanner est un examen d’imagerie irradiant. Compte-tenu des risques potentiels de cancer radio-induit liés aux faibles doses de rayons X, la réduction de la dose d’irradiation au scanner est primordiale. Dans ce travail, nous avons étudié plusieurs facteurs techniques et comportementaux qui permettent d’optimiser et de réduire la dose d’irradiation au scanner, tout en préservant une excellente performance diagnostique. Du côté des facteurs comportementaux, la sensibilisation des équipes médicales et paramédicales est fondamentale dans une démarche d’optimisation de la dose d’irradiation au scanner. De même, la limitation du nombre de phases d’acquisition et la réduction de la couverture d’acquisition sont deux manières simples pour réduire les doses délivrées. Du côté des facteurs techniques, nous avons montrés que l’utilisation des reconstructions itératives, par rapport aux reconstructions standards en rétroprojection filtrée, permet de réduire de moitié la dose d’irradiation des scanners, à qualité d’image équivalente. L’acquisition en mode volumique pour les scanners avec une faible couverture d’acquisition et l’utilisation de la modulation automatique du milliampérage permettent aussi de réduire et d’optimiser les doses. Enfin, nous nous sommes intéressés à l’optimisation de protocoles de scanner en pratique clinique courante en se focalisant sur les scanners réalisés pour la recherche d’une colique néphrétique et pour les scanners en imagerie ostéo-articulaire. Dans ce dernier domaine, nous avons aussi proposé des protocoles de scanner pour des applications cliniques avancées comme le scanner dynamique des articulations ou le scanner de perfusion tumorale","abstract_has_math":false,"creators":["Gervaise, Alban"],"institution":"Université de Lorraine","degree_name":"Docteur es","degree_level":"Doctorat","degree_discipline":"Sciences de la vie et de la santé","degree_department":null,"school":null,"contributors":["Université de Lorraine"],"advisors":["Blum, Alain"],"committee_chairs":["Drapé, Jean-Luc"],"committee_members":["Gondim Teixeira, Pedro Augusto","Noël, Alain"],"year":2016,"date_issued":"2016-10-03","date_published":"2016-10-03","updated_at":"2026-11-27T06:48:26Z","subjects":["Dose d’irradiation","Optimisation","Rayons X","Réduction","Scanner","Computed Tomography","Optimization","Radiation dose","Reduction","X-Ray","616.075 722"],"languages":["fr"],"rights":["Open Access"],"rights_urls":["http://purl.org/eprint/accessRights/OpenAccess"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2016LORR0136","https://theses.fr/2016LORR0136/abes"],"render_values":[{"text":"https://theses.fr/2016LORR0136","href":"https://theses.fr/2016LORR0136","code":true},{"text":"https://theses.fr/2016LORR0136/abes","href":"https://theses.fr/2016LORR0136/abes","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2016LORR0136/document"],"render_values":[{"text":"http://www.theses.fr/2016LORR0136/document","href":"http://www.theses.fr/2016LORR0136/document","code":true}]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["https://www.idref.fr/168689685","RNF","81479"],"render_values":[{"text":"https://www.idref.fr/168689685","href":"https://www.idref.fr/168689685","code":true},{"text":"RNF","href":null,"code":true},{"text":"81479","href":null,"code":true}]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["https://www.idref.fr/10964025X","2D"],"render_values":[{"text":"https://www.idref.fr/10964025X","href":"https://www.idref.fr/10964025X","code":true},{"text":"2D","href":null,"code":true}]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/157040569"],"render_values":[{"text":"https://www.idref.fr/157040569","href":"https://www.idref.fr/157040569","code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2016LORR0136"],"render_values":[{"text":"2016LORR0136","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/14455514X","https://www.idref.fr/034286039","https://www.idref.fr/061584258","https://www.idref.fr/177200219","https://www.idref.fr/136826520","https://www.idref.fr/136646026","https://www.idref.fr/125236212"],"render_values":[{"text":"https://www.idref.fr/14455514X","href":"https://www.idref.fr/14455514X","code":true},{"text":"https://www.idref.fr/034286039","href":"https://www.idref.fr/034286039","code":true},{"text":"https://www.idref.fr/061584258","href":"https://www.idref.fr/061584258","code":true},{"text":"https://www.idref.fr/177200219","href":"https://www.idref.fr/177200219","code":true},{"text":"https://www.idref.fr/136826520","href":"https://www.idref.fr/136826520","code":true},{"text":"https://www.idref.fr/136646026","href":"https://www.idref.fr/136646026","code":true},{"text":"https://www.idref.fr/125236212","href":"https://www.idref.fr/125236212","code":true}]},{"key":"person:identifier.student","label":"Person Identifier Student","values":["30512616"],"render_values":[{"text":"30512616","href":null,"code":true}]}]},"links":{"outbound_url":"https://doi.org/10.70675/f8bd96a9zc7f5z4fd4z9ef4z6c1e7cc09d10","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.70675/f8bd96a9zc7f5z4fd4z9ef4z6c1e7cc09d10","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astar-france%3A2016LORR0136","prefix":"oai_dc"},"source_record":{"url":"https://staroai.theses.fr/OAIHandler?verb=GetRecord&metadataPrefix=tef&identifier=2016LORR0136","prefix":"tef"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Université de Lorraine","Blum, Alain"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Blum, Alain"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Drapé, Jean-Luc"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gondim Teixeira, Pedro Augusto","Noël, Alain"]},{"key":"dc:contributor.examiner","label":"Dc Contributor Examiner","values":["Brisse, Hervé","Ducou Le Pointe, Hubert"]},{"key":"dc:contributor.researchpartner","label":"Dc Contributor Researchpartner","values":["Imagerie adaptative diagnostique et interventionnelle (Nancy)","Imagerie Adaptative Diagnostique et Interventionnelle / IADI"]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["https://www.idref.fr/168689685","RNF","81479"]},{"key":"dc:creator","label":"Author","values":["Gervaise, Alban"]},{"key":"person:birthdate","label":"Person Birthdate","values":["1981-08-14"]},{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/14455514X","https://www.idref.fr/034286039","https://www.idref.fr/061584258","https://www.idref.fr/177200219","https://www.idref.fr/136826520","https://www.idref.fr/136646026","https://www.idref.fr/125236212"]},{"key":"person:identifier.student","label":"Person Identifier Student","values":["30512616"]},{"key":"person:nationality","label":"Person Nationality","values":["FR"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-10-03"]},{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2016-10-03"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation","Text"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:by_published_works","label":"Thesis By Published Works","values":["oui"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Sciences de la vie et de la santé"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctorat"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Docteur es"]},{"key":"thesis:doctoral_school","label":"Thesis Doctoral School","values":["École doctorale BioSE - Biologie, Santé, Environnement"]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["https://www.idref.fr/10964025X","2D"]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/157040569"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Université de Lorraine"]},{"key":"thesis:jury_release_opinion","label":"Thesis Jury Release Opinion","values":["oui"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2016LORR0136"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dose d’irradiation","Optimisation","Rayons X","Réduction","Scanner","Computed Tomography","Optimization","Radiation dose","Reduction","X-Ray","616.075 722"]},{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["616.075 722"]},{"key":"dc:subject.rameau","label":"Dc Subject Rameau","values":["Rayonnements -- Dosage","Rayons X","Scanographes","Imagerie médicale -- Qualité de l'image"]},{"key":"dc:subject.uri","label":"Dc Subject URI","values":["https://www.idref.fr/02781730X","https://www.idref.fr/027480097","https://www.idref.fr/032419066","https://www.idref.fr/032565968"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["fr"]},{"key":"dc:language.rfc3066","label":"Language (RFC 3066)","values":["fr"]},{"key":"dc:rights","label":"Dc Rights","values":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"]},{"key":"dc:rights.permissions","label":"Dc Rights Permissions","values":["copy, display, duplicate, print"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2016LORR0136/document"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.70675/f8bd96a9zc7f5z4fd4z9ef4z6c1e7cc09d10"]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["LORR/THESE_86612/document/0/0/DDOC_T_2016_0136_GERVAISE.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2016LORR0136","https://theses.fr/2016LORR0136/abes"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Depuis son introduction dans les années 1970, le scanner est devenu une technique d’imagerie médicale incontournable grâce à son excellente performance pour le diagnostic de nombreuses pathologies. Toutefois, le scanner est un examen d’imagerie irradiant. Compte-tenu des risques potentiels de cancer radio-induit liés aux faibles doses de rayons X, la réduction de la dose d’irradiation au scanner est primordiale. Dans ce travail, nous avons étudié plusieurs facteurs techniques et comportementaux qui permettent d’optimiser et de réduire la dose d’irradiation au scanner, tout en préservant une excellente performance diagnostique. Du côté des facteurs comportementaux, la sensibilisation des équipes médicales et paramédicales est fondamentale dans une démarche d’optimisation de la dose d’irradiation au scanner. De même, la limitation du nombre de phases d’acquisition et la réduction de la couverture d’acquisition sont deux manières simples pour réduire les doses délivrées. Du côté des facteurs techniques, nous avons montrés que l’utilisation des reconstructions itératives, par rapport aux reconstructions standards en rétroprojection filtrée, permet de réduire de moitié la dose d’irradiation des scanners, à qualité d’image équivalente. L’acquisition en mode volumique pour les scanners avec une faible couverture d’acquisition et l’utilisation de la modulation automatique du milliampérage permettent aussi de réduire et d’optimiser les doses. Enfin, nous nous sommes intéressés à l’optimisation de protocoles de scanner en pratique clinique courante en se focalisant sur les scanners réalisés pour la recherche d’une colique néphrétique et pour les scanners en imagerie ostéo-articulaire. Dans ce dernier domaine, nous avons aussi proposé des protocoles de scanner pour des applications cliniques avancées comme le scanner dynamique des articulations ou le scanner de perfusion tumorale","Since its introduction in the 1970s, computed tomography (CT) has become the technique of reference in medical imaging for many diseases due to its high diagnostic performance. Its main limitation is the radiation dose delivered to the patient. Considering the potential risks of radiation-induced cancer caused even with low dose exposure, dose reduction in CT is essential. In this work, we studied several technical and behavioral factors that allow for CT radiation dose reduction and optimization, without modifying the diagnostic performance. Among the behavioral factors studied, education and awareness of radiologists and radiology technicians are important elements for CT radiation dose reduction. Limiting CT scan coverage and the number of acquisition phases is also a straightforward and effective way to reduce dose exposure. Regarding technical factors, we have shown that iterative reconstruction algorithms can reduce in half the radiation dose in comparison with standard filtered back projection, while maintaining equivalent image quality. The use of wide volume mode for acquisitions with a short coverage and the use of the automatic tube current modulation can also be used to reduce and optimize CT radiation dose. Finally, we provide guidelines to optimize CT radiation dose in some clinical settings such as renal colic and musculoskeletal CT. We also propose practical guidelines for advanced clinical applications of joint dynamic CT and perfusion CT in musculoskeletal disease"]},{"key":"dc:description.abstract","label":"Abstract","values":["Depuis son introduction dans les années 1970, le scanner est devenu une technique d’imagerie médicale incontournable grâce à son excellente performance pour le diagnostic de nombreuses pathologies. Toutefois, le scanner est un examen d’imagerie irradiant. Compte-tenu des risques potentiels de cancer radio-induit liés aux faibles doses de rayons X, la réduction de la dose d’irradiation au scanner est primordiale. Dans ce travail, nous avons étudié plusieurs facteurs techniques et comportementaux qui permettent d’optimiser et de réduire la dose d’irradiation au scanner, tout en préservant une excellente performance diagnostique. Du côté des facteurs comportementaux, la sensibilisation des équipes médicales et paramédicales est fondamentale dans une démarche d’optimisation de la dose d’irradiation au scanner. De même, la limitation du nombre de phases d’acquisition et la réduction de la couverture d’acquisition sont deux manières simples pour réduire les doses délivrées. Du côté des facteurs techniques, nous avons montrés que l’utilisation des reconstructions itératives, par rapport aux reconstructions standards en rétroprojection filtrée, permet de réduire de moitié la dose d’irradiation des scanners, à qualité d’image équivalente. L’acquisition en mode volumique pour les scanners avec une faible couverture d’acquisition et l’utilisation de la modulation automatique du milliampérage permettent aussi de réduire et d’optimiser les doses. Enfin, nous nous sommes intéressés à l’optimisation de protocoles de scanner en pratique clinique courante en se focalisant sur les scanners réalisés pour la recherche d’une colique néphrétique et pour les scanners en imagerie ostéo-articulaire. Dans ce dernier domaine, nous avons aussi proposé des protocoles de scanner pour des applications cliniques avancées comme le scanner dynamique des articulations ou le scanner de perfusion tumorale","Since its introduction in the 1970s, computed tomography (CT) has become the technique of reference in medical imaging for many diseases due to its high diagnostic performance. Its main limitation is the radiation dose delivered to the patient. Considering the potential risks of radiation-induced cancer caused even with low dose exposure, dose reduction in CT is essential. In this work, we studied several technical and behavioral factors that allow for CT radiation dose reduction and optimization, without modifying the diagnostic performance. Among the behavioral factors studied, education and awareness of radiologists and radiology technicians are important elements for CT radiation dose reduction. Limiting CT scan coverage and the number of acquisition phases is also a straightforward and effective way to reduce dose exposure. Regarding technical factors, we have shown that iterative reconstruction algorithms can reduce in half the radiation dose in comparison with standard filtered back projection, while maintaining equivalent image quality. The use of wide volume mode for acquisitions with a short coverage and the use of the automatic tube current modulation can also be used to reduce and optimize CT radiation dose. Finally, we provide guidelines to optimize CT radiation dose in some clinical settings such as renal colic and musculoskeletal CT. We also propose practical guidelines for advanced clinical applications of joint dynamic CT and perfusion CT in musculoskeletal disease"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["9710752"]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["PDF"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["PDF"]},{"key":"dc:title","label":"Title","values":["Optimisation et réduction de la dose d’irradiation au scanner : aspects techniques et impact en pratique clinique courante","CT radiation dose optimization and reduction : technical aspects and impact in clinical pratice"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["CT radiation dose optimization and reduction : technical aspects and impact in clinical pratice"]},{"key":"tef:authorizedname","label":"Tef Authorizedname","values":["Blum, Alain","BioSE - Ecole Doctorale Biologie, Santé, Environnement","Drapé, Jean-Luc","Imagerie adaptative diagnostique et interventionnelle (Nancy)","Gondim Teixeira, Pedro Augusto","Imagerie Adaptative Diagnostique et Interventionnelle / IADI","Noël, Alain","Brisse, Hervé","Ducou Le Pointe, Hubert"]},{"key":"tef:externalresource.creator","label":"Tef Externalresource Creator","values":["Alban Gervaise","Sandrine Esperabe-Vignau","Matthieu Pernin","Pierre Naulet","Yann Portron","Marie Lapierre-Combes","Johnny Wassel","Alain Blum","Pedro Augusto Gondim Teixeira","Gabriela Hossu","Matthias Louis","Toufik Batch","Damien Loeuille","Alain Noel","François Guillemin","Benoît Osemont","Sophie Lecocq","Emilien Micard","Jacques Felblinger","Florence Beuret","Christelle Henry","Christelle Gervaise-Henry","Camille Junca-Laplace","N. Villani","Ariane Raymond","Sabine Aptel"]},{"key":"tef:externalresource.date","label":"Tef Externalresource Date","values":["2011","2013","2016","2010","2012","2014","2015"]},{"key":"tef:externalresource.language","label":"Tef Externalresource Language","values":["fr","en"]},{"key":"tef:externalresource.publisher","label":"Tef Externalresource Publisher","values":["Journal de radiologie","Diagnostic and Interventional Imaging","British Journal of Radiology","European Radiology","American Journal of Roentgenology","European Journal of Radiology"]},{"key":"tef:externalresource.title","label":"Tef Externalresource Title","values":["Évaluation des connaissances des prescripteurs de scanner en matière de radioprotection des patients","Evaluation of the value of abdominopelvic acquisition without contrast injection when performing a whole body CT scan in a patient who may have multiple trauma","Optimizing z-axis coverage of abdominal CT scans of the urinary tract: a proposed alternative proximal landmark for acquisition planning","Réduction de dose dans l’exploration du rachis lombaire grâce au scanner 320-détecteurs : étude initiale","CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT","Standard dose versus low-dose abdominal and pelvic CT: Comparison between filtered back projection versus adaptive iterative dose reduction 3D","Low-dose CT with automatic tube current modulation, adaptive statistical iterative reconstruction, and low tube voltage for the diagnosis of renal colic: impact of body mass index","How to perform low-dose computed tomography for renal colic in clinical practice","CT dose optimisation and reduction in osteoarticular disease","Musculoskeletal wide detector CT: Principles, techniques and applications in clinical practice and research"]},{"key":"tef:externalresource.type","label":"Tef Externalresource Type","values":["Text"]},{"key":"tef:internalref","label":"Tef Internalref","values":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2","MADS_PARTENAIRE_DE_RECHERCHE_2"]},{"key":"tef:oaisetspec","label":"Tef Oaisetspec","values":["ddc:610"]},{"key":"tef:record.agent","label":"Tef Record Agent","values":["ABES"]},{"key":"tef:record.agentnote","label":"Tef Record Agentnote","values":["Note"]},{"key":"tef:record.created","label":"Tef Record Created","values":["2017-03-15T17:06:16"]},{"key":"tef:record.modified","label":"Tef Record Modified","values":["2023-01-18T03:46:57Z"]},{"key":"tef:record.status","label":"Tef Record Status","values":["valide"]}]}],"canonical_facts":{"dc:contributor":["Université de Lorraine","Blum, Alain"],"dc:contributor.advisor":["Blum, Alain"],"dc:contributor.committeechair":["Drapé, Jean-Luc"],"dc:contributor.committeemember":["Gondim Teixeira, Pedro Augusto","Noël, Alain"],"dc:contributor.examiner":["Brisse, Hervé","Ducou Le Pointe, Hubert"],"dc:contributor.researchpartner":["Imagerie adaptative diagnostique et interventionnelle (Nancy)","Imagerie Adaptative Diagnostique et Interventionnelle / IADI"],"dc:contributor.researchpartner.identifier":["https://www.idref.fr/168689685","RNF","81479"],"dc:creator":["Gervaise, Alban"],"dc:date":["2016-10-03"],"dc:date.dateaccepted":["2016-10-03"],"dc:description":["Depuis son introduction dans les années 1970, le scanner est devenu une technique d’imagerie médicale incontournable grâce à son excellente performance pour le diagnostic de nombreuses pathologies. Toutefois, le scanner est un examen d’imagerie irradiant. Compte-tenu des risques potentiels de cancer radio-induit liés aux faibles doses de rayons X, la réduction de la dose d’irradiation au scanner est primordiale. Dans ce travail, nous avons étudié plusieurs facteurs techniques et comportementaux qui permettent d’optimiser et de réduire la dose d’irradiation au scanner, tout en préservant une excellente performance diagnostique. Du côté des facteurs comportementaux, la sensibilisation des équipes médicales et paramédicales est fondamentale dans une démarche d’optimisation de la dose d’irradiation au scanner. De même, la limitation du nombre de phases d’acquisition et la réduction de la couverture d’acquisition sont deux manières simples pour réduire les doses délivrées. Du côté des facteurs techniques, nous avons montrés que l’utilisation des reconstructions itératives, par rapport aux reconstructions standards en rétroprojection filtrée, permet de réduire de moitié la dose d’irradiation des scanners, à qualité d’image équivalente. L’acquisition en mode volumique pour les scanners avec une faible couverture d’acquisition et l’utilisation de la modulation automatique du milliampérage permettent aussi de réduire et d’optimiser les doses. Enfin, nous nous sommes intéressés à l’optimisation de protocoles de scanner en pratique clinique courante en se focalisant sur les scanners réalisés pour la recherche d’une colique néphrétique et pour les scanners en imagerie ostéo-articulaire. Dans ce dernier domaine, nous avons aussi proposé des protocoles de scanner pour des applications cliniques avancées comme le scanner dynamique des articulations ou le scanner de perfusion tumorale","Since its introduction in the 1970s, computed tomography (CT) has become the technique of reference in medical imaging for many diseases due to its high diagnostic performance. Its main limitation is the radiation dose delivered to the patient. Considering the potential risks of radiation-induced cancer caused even with low dose exposure, dose reduction in CT is essential. In this work, we studied several technical and behavioral factors that allow for CT radiation dose reduction and optimization, without modifying the diagnostic performance. Among the behavioral factors studied, education and awareness of radiologists and radiology technicians are important elements for CT radiation dose reduction. Limiting CT scan coverage and the number of acquisition phases is also a straightforward and effective way to reduce dose exposure. Regarding technical factors, we have shown that iterative reconstruction algorithms can reduce in half the radiation dose in comparison with standard filtered back projection, while maintaining equivalent image quality. The use of wide volume mode for acquisitions with a short coverage and the use of the automatic tube current modulation can also be used to reduce and optimize CT radiation dose. Finally, we provide guidelines to optimize CT radiation dose in some clinical settings such as renal colic and musculoskeletal CT. We also propose practical guidelines for advanced clinical applications of joint dynamic CT and perfusion CT in musculoskeletal disease"],"dc:description.abstract":["Depuis son introduction dans les années 1970, le scanner est devenu une technique d’imagerie médicale incontournable grâce à son excellente performance pour le diagnostic de nombreuses pathologies. Toutefois, le scanner est un examen d’imagerie irradiant. Compte-tenu des risques potentiels de cancer radio-induit liés aux faibles doses de rayons X, la réduction de la dose d’irradiation au scanner est primordiale. Dans ce travail, nous avons étudié plusieurs facteurs techniques et comportementaux qui permettent d’optimiser et de réduire la dose d’irradiation au scanner, tout en préservant une excellente performance diagnostique. Du côté des facteurs comportementaux, la sensibilisation des équipes médicales et paramédicales est fondamentale dans une démarche d’optimisation de la dose d’irradiation au scanner. De même, la limitation du nombre de phases d’acquisition et la réduction de la couverture d’acquisition sont deux manières simples pour réduire les doses délivrées. Du côté des facteurs techniques, nous avons montrés que l’utilisation des reconstructions itératives, par rapport aux reconstructions standards en rétroprojection filtrée, permet de réduire de moitié la dose d’irradiation des scanners, à qualité d’image équivalente. L’acquisition en mode volumique pour les scanners avec une faible couverture d’acquisition et l’utilisation de la modulation automatique du milliampérage permettent aussi de réduire et d’optimiser les doses. Enfin, nous nous sommes intéressés à l’optimisation de protocoles de scanner en pratique clinique courante en se focalisant sur les scanners réalisés pour la recherche d’une colique néphrétique et pour les scanners en imagerie ostéo-articulaire. Dans ce dernier domaine, nous avons aussi proposé des protocoles de scanner pour des applications cliniques avancées comme le scanner dynamique des articulations ou le scanner de perfusion tumorale","Since its introduction in the 1970s, computed tomography (CT) has become the technique of reference in medical imaging for many diseases due to its high diagnostic performance. Its main limitation is the radiation dose delivered to the patient. Considering the potential risks of radiation-induced cancer caused even with low dose exposure, dose reduction in CT is essential. In this work, we studied several technical and behavioral factors that allow for CT radiation dose reduction and optimization, without modifying the diagnostic performance. Among the behavioral factors studied, education and awareness of radiologists and radiology technicians are important elements for CT radiation dose reduction. Limiting CT scan coverage and the number of acquisition phases is also a straightforward and effective way to reduce dose exposure. Regarding technical factors, we have shown that iterative reconstruction algorithms can reduce in half the radiation dose in comparison with standard filtered back projection, while maintaining equivalent image quality. The use of wide volume mode for acquisitions with a short coverage and the use of the automatic tube current modulation can also be used to reduce and optimize CT radiation dose. Finally, we provide guidelines to optimize CT radiation dose in some clinical settings such as renal colic and musculoskeletal CT. We also propose practical guidelines for advanced clinical applications of joint dynamic CT and perfusion CT in musculoskeletal disease"],"dc:format.extent":["9710752"],"dc:format.filetype":["PDF"],"dc:format.medium":["PDF"],"dc:identifier":["http://www.theses.fr/2016LORR0136/document"],"dc:identifier.doi":["https://doi.org/10.70675/f8bd96a9zc7f5z4fd4z9ef4z6c1e7cc09d10"],"dc:identifier.fulltext":["LORR/THESE_86612/document/0/0/DDOC_T_2016_0136_GERVAISE.pdf"],"dc:identifier.uri":["https://theses.fr/2016LORR0136","https://theses.fr/2016LORR0136/abes"],"dc:language":["fr"],"dc:language.rfc3066":["fr"],"dc:rights":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"],"dc:rights.permissions":["copy, display, duplicate, print"],"dc:subject":["Dose d’irradiation","Optimisation","Rayons X","Réduction","Scanner","Computed Tomography","Optimization","Radiation dose","Reduction","X-Ray","616.075 722"],"dc:subject.ddc":["616.075 722"],"dc:subject.rameau":["Rayonnements -- Dosage","Rayons X","Scanographes","Imagerie médicale -- Qualité de l'image"],"dc:subject.uri":["https://www.idref.fr/02781730X","https://www.idref.fr/027480097","https://www.idref.fr/032419066","https://www.idref.fr/032565968"],"dc:title":["Optimisation et réduction de la dose d’irradiation au scanner : aspects techniques et impact en pratique clinique courante","CT radiation dose optimization and reduction : technical aspects and impact in clinical pratice"],"dc:title.alternative":["CT radiation dose optimization and reduction : technical aspects and impact in clinical pratice"],"dc:type":["Electronic Thesis or Dissertation","Text"],"dc:type.dcmitype":["Text"],"person:birthdate":["1981-08-14"],"person:identifier.idref":["https://www.idref.fr/14455514X","https://www.idref.fr/034286039","https://www.idref.fr/061584258","https://www.idref.fr/177200219","https://www.idref.fr/136826520","https://www.idref.fr/136646026","https://www.idref.fr/125236212"],"person:identifier.student":["30512616"],"person:nationality":["FR"],"tef:authorizedname":["Blum, Alain","BioSE - Ecole Doctorale Biologie, Santé, Environnement","Drapé, Jean-Luc","Imagerie adaptative diagnostique et interventionnelle (Nancy)","Gondim Teixeira, Pedro Augusto","Imagerie Adaptative Diagnostique et Interventionnelle / IADI","Noël, Alain","Brisse, Hervé","Ducou Le Pointe, Hubert"],"tef:externalresource.creator":["Alban Gervaise","Sandrine Esperabe-Vignau","Matthieu Pernin","Pierre Naulet","Yann Portron","Marie Lapierre-Combes","Johnny Wassel","Alain Blum","Pedro Augusto Gondim Teixeira","Gabriela Hossu","Matthias Louis","Toufik Batch","Damien Loeuille","Alain Noel","François Guillemin","Benoît Osemont","Sophie Lecocq","Emilien Micard","Jacques Felblinger","Florence Beuret","Christelle Henry","Christelle Gervaise-Henry","Camille Junca-Laplace","N. Villani","Ariane Raymond","Sabine Aptel"],"tef:externalresource.date":["2011","2013","2016","2010","2012","2014","2015"],"tef:externalresource.language":["fr","en"],"tef:externalresource.publisher":["Journal de radiologie","Diagnostic and Interventional Imaging","British Journal of Radiology","European Radiology","American Journal of Roentgenology","European Journal of Radiology"],"tef:externalresource.title":["Évaluation des connaissances des prescripteurs de scanner en matière de radioprotection des patients","Evaluation of the value of abdominopelvic acquisition without contrast injection when performing a whole body CT scan in a patient who may have multiple trauma","Optimizing z-axis coverage of abdominal CT scans of the urinary tract: a proposed alternative proximal landmark for acquisition planning","Réduction de dose dans l’exploration du rachis lombaire grâce au scanner 320-détecteurs : étude initiale","CT image quality improvement using Adaptive Iterative Dose Reduction with wide-volume acquisition on 320-detector CT","Standard dose versus low-dose abdominal and pelvic CT: Comparison between filtered back projection versus adaptive iterative dose reduction 3D","Low-dose CT with automatic tube current modulation, adaptive statistical iterative reconstruction, and low tube voltage for the diagnosis of renal colic: impact of body mass index","How to perform low-dose computed tomography for renal colic in clinical practice","CT dose optimisation and reduction in osteoarticular disease","Musculoskeletal wide detector CT: Principles, techniques and applications in clinical practice and research"],"tef:externalresource.type":["Text"],"tef:internalref":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2","MADS_PARTENAIRE_DE_RECHERCHE_2"],"tef:oaisetspec":["ddc:610"],"tef:record.agent":["ABES"],"tef:record.agentnote":["Note"],"tef:record.created":["2017-03-15T17:06:16"],"tef:record.modified":["2023-01-18T03:46:57Z"],"tef:record.status":["valide"],"thesis:by_published_works":["oui"],"thesis:degree_discipline":["Sciences de la vie et de la santé"],"thesis:degree_level":["Doctorat"],"thesis:degree_name":["Docteur es"],"thesis:doctoral_school":["École doctorale BioSE - Biologie, Santé, Environnement"],"thesis:doctoral_school_identifier":["https://www.idref.fr/10964025X","2D"],"thesis:institution_identifier":["https://www.idref.fr/157040569"],"thesis:institution_name":["Université de Lorraine"],"thesis:jury_release_opinion":["oui"],"thesis:thesis_identifier":["2016LORR0136"]},"updated_at":"2026-11-27T06:48:26Z"}