{"id":{"repo_id":"star-france","oai_identifier":"2017TOUR4026"},"canonical_url":"https://search.ndltd.org/etd/star-france/2017TOUR4026","repository":{"repo_id":"star-france","name":"STAR","base_url":"https://staroai.theses.fr/OAIHandler"},"display":{"title":"Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés","abstract":"Les transducteurs ultrasonores capacitifs micro-usinés (CMUT) représentent aujourd’hui une réelle alternative aux technologies piézoélectriques dans le domaine de l’imagerie échographique médicale. Au cours des années, les procédés de fabrication des transducteurs se sont enrichis en vue d’améliorer leurs performances. A contrario le choix du substrat, généralement en silicium, a été peu étudié. Il est cependant reconnu que le support contribue à la signature acoustique du dispositif ultrasonore. L’objectif de ces travaux de thèse a été d’intégrer une couche de silicium poreux afin d’absorber une partie des ondes élastiques qui se propagent dans le substrat et interfèrent avec le signal acoustique émis. Nous montrons alors qu’il été possible de réaliser une couche de silicium poreux en face arrière de composants, sur plaquettes 6 pouces, sans dégrader leurs performances. Finalement, par l’intermédiaire de caractérisations acoustiques et des signatures impulsionnelles des transducteurs, nous révélons le potentiel prometteur de ce matériaux pour la réalisation de milieu arrière atténuant dédié à la transduction ultrasonore.","abstract_html":"Les transducteurs ultrasonores capacitifs micro-usinés (CMUT) représentent aujourd’hui une réelle alternative aux technologies piézoélectriques dans le domaine de l’imagerie échographique médicale. Au cours des années, les procédés de fabrication des transducteurs se sont enrichis en vue d’améliorer leurs performances. A contrario le choix du substrat, généralement en silicium, a été peu étudié. Il est cependant reconnu que le support contribue à la signature acoustique du dispositif ultrasonore. L’objectif de ces travaux de thèse a été d’intégrer une couche de silicium poreux afin d’absorber une partie des ondes élastiques qui se propagent dans le substrat et interfèrent avec le signal acoustique émis. Nous montrons alors qu’il été possible de réaliser une couche de silicium poreux en face arrière de composants, sur plaquettes 6 pouces, sans dégrader leurs performances. Finalement, par l’intermédiaire de caractérisations acoustiques et des signatures impulsionnelles des transducteurs, nous révélons le potentiel prometteur de ce matériaux pour la réalisation de milieu arrière atténuant dédié à la transduction ultrasonore.","abstract_has_math":false,"creators":["Lascaud, Julie"],"institution":"Tours","degree_name":"Docteur es","degree_level":"Doctorat","degree_discipline":"Electronique","degree_department":null,"school":null,"contributors":["Tours"],"advisors":["Gautier, Gaël","Certon, Dominique"],"committee_chairs":["Alquier, Daniel"],"committee_members":["Savoia, Alessandro"],"year":2017,"date_issued":"2017-12-31","date_published":"2017-12-31","updated_at":"2026-11-27T06:53:42Z","subjects":["Couche atténuante","Silicium poreux","Transducteurs ultrasonores","Gravure électrochimique","Caractérisations acoustiques","CMUT","Backing layer","Porous silicon","Ultrasonic transducers","Electrochemical etching","Acoustic characterizations"],"languages":["fr"],"rights":["Open Access"],"rights_urls":["http://purl.org/eprint/accessRights/OpenAccess"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2017TOUR4026","http://theses.scd.univ-tours.fr/index.php?fichier=2017/julie.lascaud_8325.pdf","https://theses.fr/2017TOUR4026/abes"],"render_values":[{"text":"https://theses.fr/2017TOUR4026","href":"https://theses.fr/2017TOUR4026","code":true},{"text":"http://theses.scd.univ-tours.fr/index.php?fichier=2017/julie.lascaud_8325.pdf","href":"http://theses.scd.univ-tours.fr/index.php?fichier=2017/julie.lascaud_8325.pdf","code":true},{"text":"https://theses.fr/2017TOUR4026/abes","href":"https://theses.fr/2017TOUR4026/abes","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2017TOUR4026/document"],"render_values":[{"text":"http://www.theses.fr/2017TOUR4026/document","href":"http://www.theses.fr/2017TOUR4026/document","code":true}]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["GREMAN","https://www.idref.fr/228797675","https://www.idref.fr/112943365"],"render_values":[{"text":"GREMAN","href":null,"code":true},{"text":"https://www.idref.fr/228797675","href":"https://www.idref.fr/228797675","code":true},{"text":"https://www.idref.fr/112943365","href":"https://www.idref.fr/112943365","code":true}]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["06","https://www.idref.fr/161142001"],"render_values":[{"text":"06","href":null,"code":true},{"text":"https://www.idref.fr/161142001","href":"https://www.idref.fr/161142001","code":true}]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/026404478"],"render_values":[{"text":"https://www.idref.fr/026404478","href":"https://www.idref.fr/026404478","code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2017TOUR4026"],"render_values":[{"text":"2017TOUR4026","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/226607143","https://www.idref.fr/069994293","https://www.idref.fr/128188308","https://www.idref.fr/193251914","https://www.idref.fr/071208453","https://www.idref.fr/13681803X","https://www.idref.fr/12080641X"],"render_values":[{"text":"https://www.idref.fr/226607143","href":"https://www.idref.fr/226607143","code":true},{"text":"https://www.idref.fr/069994293","href":"https://www.idref.fr/069994293","code":true},{"text":"https://www.idref.fr/128188308","href":"https://www.idref.fr/128188308","code":true},{"text":"https://www.idref.fr/193251914","href":"https://www.idref.fr/193251914","code":true},{"text":"https://www.idref.fr/071208453","href":"https://www.idref.fr/071208453","code":true},{"text":"https://www.idref.fr/13681803X","href":"https://www.idref.fr/13681803X","code":true},{"text":"https://www.idref.fr/12080641X","href":"https://www.idref.fr/12080641X","code":true}]},{"key":"person:identifier.student","label":"Person Identifier Student","values":["21106060"],"render_values":[{"text":"21106060","href":null,"code":true}]}]},"links":{"outbound_url":"https://doi.org/10.70675/cd0cda8aze9f2z4c5fz8c8czcfa5d4a5b7bc","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.70675/cd0cda8aze9f2z4c5fz8c8czcfa5d4a5b7bc","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astar-france%3A2017TOUR4026","prefix":"oai_dc"},"source_record":{"url":"https://staroai.theses.fr/OAIHandler?verb=GetRecord&metadataPrefix=tef&identifier=2017TOUR4026","prefix":"tef"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Tours","Gautier, Gaël","Certon, Dominique"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Gautier, Gaël","Certon, Dominique"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Alquier, Daniel"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Savoia, Alessandro"]},{"key":"dc:contributor.examiner","label":"Dc Contributor Examiner","values":["Lysenko, Vladimir S.","Déjous, Corinne"]},{"key":"dc:contributor.researchpartner","label":"Dc Contributor Researchpartner","values":["Laboratoire GREMAN (Tours)","École polytechnique universitaire (Tours)"]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["GREMAN","https://www.idref.fr/228797675","https://www.idref.fr/112943365"]},{"key":"dc:creator","label":"Author","values":["Lascaud, Julie"]},{"key":"person:birthdate","label":"Person Birthdate","values":["1991-08-28"]},{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/226607143","https://www.idref.fr/069994293","https://www.idref.fr/128188308","https://www.idref.fr/193251914","https://www.idref.fr/071208453","https://www.idref.fr/13681803X","https://www.idref.fr/12080641X"]},{"key":"person:identifier.student","label":"Person Identifier Student","values":["21106060"]},{"key":"person:nationality","label":"Person Nationality","values":["FR"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2017-12-11"]},{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2017-12-11"]},{"key":"dc:date.issued","label":"Date","values":["2017-12-31"]},{"key":"dc:publisher","label":"Institution","values":["SCD de l'université de Tours"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Tours"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation","Text"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:by_published_works","label":"Thesis By Published Works","values":["non"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electronique"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctorat"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Docteur es"]},{"key":"thesis:doctoral_school","label":"Thesis Doctoral School","values":["École doctorale Énergie, Matériaux, Sciences de la Terre et de l'Univers (Centre-Val de Loire ; 2012-....)"]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["06","https://www.idref.fr/161142001"]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/026404478"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Tours"]},{"key":"thesis:jury_release_opinion","label":"Thesis Jury Release Opinion","values":["oui"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2017TOUR4026"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Couche atténuante","Silicium poreux","Transducteurs ultrasonores","Gravure électrochimique","Caractérisations acoustiques","CMUT","Backing layer","Porous silicon","Ultrasonic transducers","Electrochemical etching","Acoustic characterizations"]},{"key":"dc:subject.rameau","label":"Dc Subject Rameau","values":["Silicium poreux","Silicium -- Couches minces","Transducteurs ultrasonores -- Propriétés acoustiques","Micro-usinage","Semiconducteurs -- Attaque à l'acide","Plaquettes à gravure en semiconducteurs","Matériaux à gradient fonctionnel","Impédance électrique","Ondes de Lamb","Silicium -- Substrats","Impédance acoustique -- Mesure"]},{"key":"dc:subject.uri","label":"Dc Subject URI","values":["https://www.idref.fr/050201468","https://www.idref.fr/031376290","https://www.idref.fr/031412947","https://www.idref.fr/027811948","https://www.idref.fr/034779078","https://www.idref.fr/053523156","https://www.idref.fr/032678231","https://www.idref.fr/156488248","https://www.idref.fr/02964156X","https://www.idref.fr/035815604","https://www.idref.fr/031376398","https://www.idref.fr/050124072"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["fr"]},{"key":"dc:language.rfc3066","label":"Language (RFC 3066)","values":["fr"]},{"key":"dc:rights","label":"Dc Rights","values":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"]},{"key":"dc:rights.permissions","label":"Dc Rights Permissions","values":["copy, display, duplicate, print"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2017TOUR4026/document"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.70675/cd0cda8aze9f2z4c5fz8c8czcfa5d4a5b7bc"]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["TOUR/THESE_100602/document/0/0/julielascaud_8325.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2017TOUR4026","http://theses.scd.univ-tours.fr/index.php?fichier=2017/julie.lascaud_8325.pdf","https://theses.fr/2017TOUR4026/abes"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Les transducteurs ultrasonores capacitifs micro-usinés (CMUT) représentent aujourd’hui une réelle alternative aux technologies piézoélectriques dans le domaine de l’imagerie échographique médicale. Au cours des années, les procédés de fabrication des transducteurs se sont enrichis en vue d’améliorer leurs performances. A contrario le choix du substrat, généralement en silicium, a été peu étudié. Il est cependant reconnu que le support contribue à la signature acoustique du dispositif ultrasonore. L’objectif de ces travaux de thèse a été d’intégrer une couche de silicium poreux afin d’absorber une partie des ondes élastiques qui se propagent dans le substrat et interfèrent avec le signal acoustique émis. Nous montrons alors qu’il été possible de réaliser une couche de silicium poreux en face arrière de composants, sur plaquettes 6 pouces, sans dégrader leurs performances. Finalement, par l’intermédiaire de caractérisations acoustiques et des signatures impulsionnelles des transducteurs, nous révélons le potentiel prometteur de ce matériaux pour la réalisation de milieu arrière atténuant dédié à la transduction ultrasonore.","Capacitive micromachined ultrasonic transducers (CMUT) have emerged as a potential alternative to traditional piezoelectric transducers for ultrasound imaging. Along the years, CMUT processes have been evolved to enhance the device performances. In the meantime, no particular attention was paid on the silicon substrate, even if it is well-known that it could contribute to the transducer efficiency. The aim of this PhD thesis was to use porous silicon as a backing material for ultrasonic transducers to absorb a piece of the acoustic wave propagating in the substrate and which induce crosstalks in the acoustic signal. We show that porous silicon layer can be obtained on the rear side of already processed wafers without any damage on the performances of capacitive micromachined ultrasonic transducers. Finally, by means of acoustic characterizations and the transducer electroacoustic responses, we reveal the potential interest of porous silicon as backing material for ultrasonic transducers."]},{"key":"dc:description.abstract","label":"Abstract","values":["Les transducteurs ultrasonores capacitifs micro-usinés (CMUT) représentent aujourd’hui une réelle alternative aux technologies piézoélectriques dans le domaine de l’imagerie échographique médicale. Au cours des années, les procédés de fabrication des transducteurs se sont enrichis en vue d’améliorer leurs performances. A contrario le choix du substrat, généralement en silicium, a été peu étudié. Il est cependant reconnu que le support contribue à la signature acoustique du dispositif ultrasonore. L’objectif de ces travaux de thèse a été d’intégrer une couche de silicium poreux afin d’absorber une partie des ondes élastiques qui se propagent dans le substrat et interfèrent avec le signal acoustique émis. Nous montrons alors qu’il été possible de réaliser une couche de silicium poreux en face arrière de composants, sur plaquettes 6 pouces, sans dégrader leurs performances. Finalement, par l’intermédiaire de caractérisations acoustiques et des signatures impulsionnelles des transducteurs, nous révélons le potentiel prometteur de ce matériaux pour la réalisation de milieu arrière atténuant dédié à la transduction ultrasonore.","Capacitive micromachined ultrasonic transducers (CMUT) have emerged as a potential alternative to traditional piezoelectric transducers for ultrasound imaging. Along the years, CMUT processes have been evolved to enhance the device performances. In the meantime, no particular attention was paid on the silicon substrate, even if it is well-known that it could contribute to the transducer efficiency. The aim of this PhD thesis was to use porous silicon as a backing material for ultrasonic transducers to absorb a piece of the acoustic wave propagating in the substrate and which induce crosstalks in the acoustic signal. We show that porous silicon layer can be obtained on the rear side of already processed wafers without any damage on the performances of capacitive micromachined ultrasonic transducers. Finally, by means of acoustic characterizations and the transducer electroacoustic responses, we reveal the potential interest of porous silicon as backing material for ultrasonic transducers."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["9595263"]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["PDF"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["PDF"]},{"key":"dc:title","label":"Title","values":["Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés","Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic"]},{"key":"tef:authorizedname","label":"Tef Authorizedname","values":["Gautier, Gaël","École doctorale Énergie, Matériaux, Sciences de la Terre et de l'Univers (Centre-Val de Loire)","Certon, Dominique","Laboratoire GREMAN (Tours)","Alquier, Daniel","Université de Tours. Ecole polytechnique universitaire","Savoia, Alessandro","Lysenko, Vladimir S.","Déjous, Corinne"]},{"key":"tef:internalref","label":"Tef Internalref","values":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_DIRECTEUR_DE_THESE_2","MADS_RAPPORTEUR_2","MADS_PARTENAIRE_DE_RECHERCHE_2"]},{"key":"tef:oaisetspec","label":"Tef Oaisetspec","values":["ddc:620"]},{"key":"tef:record.agent","label":"Tef Record Agent","values":["ABES"]},{"key":"tef:record.agentnote","label":"Tef Record Agentnote","values":["Note"]},{"key":"tef:record.created","label":"Tef Record Created","values":["2018-01-15T09:24:54"]},{"key":"tef:record.modified","label":"Tef Record Modified","values":["2025-09-17T14:39:25Z"]},{"key":"tef:record.status","label":"Tef Record Status","values":["valide"]}]}],"canonical_facts":{"dc:contributor":["Tours","Gautier, Gaël","Certon, Dominique"],"dc:contributor.advisor":["Gautier, Gaël","Certon, Dominique"],"dc:contributor.committeechair":["Alquier, Daniel"],"dc:contributor.committeemember":["Savoia, Alessandro"],"dc:contributor.examiner":["Lysenko, Vladimir S.","Déjous, Corinne"],"dc:contributor.researchpartner":["Laboratoire GREMAN (Tours)","École polytechnique universitaire (Tours)"],"dc:contributor.researchpartner.identifier":["GREMAN","https://www.idref.fr/228797675","https://www.idref.fr/112943365"],"dc:creator":["Lascaud, Julie"],"dc:date":["2017-12-11"],"dc:date.dateaccepted":["2017-12-11"],"dc:date.issued":["2017-12-31"],"dc:description":["Les transducteurs ultrasonores capacitifs micro-usinés (CMUT) représentent aujourd’hui une réelle alternative aux technologies piézoélectriques dans le domaine de l’imagerie échographique médicale. Au cours des années, les procédés de fabrication des transducteurs se sont enrichis en vue d’améliorer leurs performances. A contrario le choix du substrat, généralement en silicium, a été peu étudié. Il est cependant reconnu que le support contribue à la signature acoustique du dispositif ultrasonore. L’objectif de ces travaux de thèse a été d’intégrer une couche de silicium poreux afin d’absorber une partie des ondes élastiques qui se propagent dans le substrat et interfèrent avec le signal acoustique émis. Nous montrons alors qu’il été possible de réaliser une couche de silicium poreux en face arrière de composants, sur plaquettes 6 pouces, sans dégrader leurs performances. Finalement, par l’intermédiaire de caractérisations acoustiques et des signatures impulsionnelles des transducteurs, nous révélons le potentiel prometteur de ce matériaux pour la réalisation de milieu arrière atténuant dédié à la transduction ultrasonore.","Capacitive micromachined ultrasonic transducers (CMUT) have emerged as a potential alternative to traditional piezoelectric transducers for ultrasound imaging. Along the years, CMUT processes have been evolved to enhance the device performances. In the meantime, no particular attention was paid on the silicon substrate, even if it is well-known that it could contribute to the transducer efficiency. The aim of this PhD thesis was to use porous silicon as a backing material for ultrasonic transducers to absorb a piece of the acoustic wave propagating in the substrate and which induce crosstalks in the acoustic signal. We show that porous silicon layer can be obtained on the rear side of already processed wafers without any damage on the performances of capacitive micromachined ultrasonic transducers. Finally, by means of acoustic characterizations and the transducer electroacoustic responses, we reveal the potential interest of porous silicon as backing material for ultrasonic transducers."],"dc:description.abstract":["Les transducteurs ultrasonores capacitifs micro-usinés (CMUT) représentent aujourd’hui une réelle alternative aux technologies piézoélectriques dans le domaine de l’imagerie échographique médicale. Au cours des années, les procédés de fabrication des transducteurs se sont enrichis en vue d’améliorer leurs performances. A contrario le choix du substrat, généralement en silicium, a été peu étudié. Il est cependant reconnu que le support contribue à la signature acoustique du dispositif ultrasonore. L’objectif de ces travaux de thèse a été d’intégrer une couche de silicium poreux afin d’absorber une partie des ondes élastiques qui se propagent dans le substrat et interfèrent avec le signal acoustique émis. Nous montrons alors qu’il été possible de réaliser une couche de silicium poreux en face arrière de composants, sur plaquettes 6 pouces, sans dégrader leurs performances. Finalement, par l’intermédiaire de caractérisations acoustiques et des signatures impulsionnelles des transducteurs, nous révélons le potentiel prometteur de ce matériaux pour la réalisation de milieu arrière atténuant dédié à la transduction ultrasonore.","Capacitive micromachined ultrasonic transducers (CMUT) have emerged as a potential alternative to traditional piezoelectric transducers for ultrasound imaging. Along the years, CMUT processes have been evolved to enhance the device performances. In the meantime, no particular attention was paid on the silicon substrate, even if it is well-known that it could contribute to the transducer efficiency. The aim of this PhD thesis was to use porous silicon as a backing material for ultrasonic transducers to absorb a piece of the acoustic wave propagating in the substrate and which induce crosstalks in the acoustic signal. We show that porous silicon layer can be obtained on the rear side of already processed wafers without any damage on the performances of capacitive micromachined ultrasonic transducers. Finally, by means of acoustic characterizations and the transducer electroacoustic responses, we reveal the potential interest of porous silicon as backing material for ultrasonic transducers."],"dc:format.extent":["9595263"],"dc:format.filetype":["PDF"],"dc:format.medium":["PDF"],"dc:identifier":["http://www.theses.fr/2017TOUR4026/document"],"dc:identifier.doi":["https://doi.org/10.70675/cd0cda8aze9f2z4c5fz8c8czcfa5d4a5b7bc"],"dc:identifier.fulltext":["TOUR/THESE_100602/document/0/0/julielascaud_8325.pdf"],"dc:identifier.uri":["https://theses.fr/2017TOUR4026","http://theses.scd.univ-tours.fr/index.php?fichier=2017/julie.lascaud_8325.pdf","https://theses.fr/2017TOUR4026/abes"],"dc:language":["fr"],"dc:language.rfc3066":["fr"],"dc:publisher":["SCD de l'université de Tours"],"dc:publisher.place":["Tours"],"dc:rights":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"],"dc:rights.permissions":["copy, display, duplicate, print"],"dc:subject":["Couche atténuante","Silicium poreux","Transducteurs ultrasonores","Gravure électrochimique","Caractérisations acoustiques","CMUT","Backing layer","Porous silicon","Ultrasonic transducers","Electrochemical etching","Acoustic characterizations"],"dc:subject.rameau":["Silicium poreux","Silicium -- Couches minces","Transducteurs ultrasonores -- Propriétés acoustiques","Micro-usinage","Semiconducteurs -- Attaque à l'acide","Plaquettes à gravure en semiconducteurs","Matériaux à gradient fonctionnel","Impédance électrique","Ondes de Lamb","Silicium -- Substrats","Impédance acoustique -- Mesure"],"dc:subject.uri":["https://www.idref.fr/050201468","https://www.idref.fr/031376290","https://www.idref.fr/031412947","https://www.idref.fr/027811948","https://www.idref.fr/034779078","https://www.idref.fr/053523156","https://www.idref.fr/032678231","https://www.idref.fr/156488248","https://www.idref.fr/02964156X","https://www.idref.fr/035815604","https://www.idref.fr/031376398","https://www.idref.fr/050124072"],"dc:title":["Elaboration de couches minces atténuantes en silicium poreux : Application aux transducteurs ultrasonores capacitifs micro-usinés","Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic"],"dc:title.alternative":["Development of thin attenuating porous silicon layers : application to the capacitive micromachine ultrasonic"],"dc:type":["Electronic Thesis or Dissertation","Text"],"dc:type.dcmitype":["Text"],"person:birthdate":["1991-08-28"],"person:identifier.idref":["https://www.idref.fr/226607143","https://www.idref.fr/069994293","https://www.idref.fr/128188308","https://www.idref.fr/193251914","https://www.idref.fr/071208453","https://www.idref.fr/13681803X","https://www.idref.fr/12080641X"],"person:identifier.student":["21106060"],"person:nationality":["FR"],"tef:authorizedname":["Gautier, Gaël","École doctorale Énergie, Matériaux, Sciences de la Terre et de l'Univers (Centre-Val de Loire)","Certon, Dominique","Laboratoire GREMAN (Tours)","Alquier, Daniel","Université de Tours. Ecole polytechnique universitaire","Savoia, Alessandro","Lysenko, Vladimir S.","Déjous, Corinne"],"tef:internalref":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_DIRECTEUR_DE_THESE_2","MADS_RAPPORTEUR_2","MADS_PARTENAIRE_DE_RECHERCHE_2"],"tef:oaisetspec":["ddc:620"],"tef:record.agent":["ABES"],"tef:record.agentnote":["Note"],"tef:record.created":["2018-01-15T09:24:54"],"tef:record.modified":["2025-09-17T14:39:25Z"],"tef:record.status":["valide"],"thesis:by_published_works":["non"],"thesis:degree_discipline":["Electronique"],"thesis:degree_level":["Doctorat"],"thesis:degree_name":["Docteur es"],"thesis:doctoral_school":["École doctorale Énergie, Matériaux, Sciences de la Terre et de l'Univers (Centre-Val de Loire ; 2012-....)"],"thesis:doctoral_school_identifier":["06","https://www.idref.fr/161142001"],"thesis:institution_identifier":["https://www.idref.fr/026404478"],"thesis:institution_name":["Tours"],"thesis:jury_release_opinion":["oui"],"thesis:thesis_identifier":["2017TOUR4026"]},"updated_at":"2026-11-27T06:53:42Z"}