{"id":{"repo_id":"star-france","oai_identifier":"2018STRAE010"},"canonical_url":"https://search.ndltd.org/etd/star-france/2018STRAE010","repository":{"repo_id":"star-france","name":"STAR","base_url":"https://staroai.theses.fr/OAIHandler"},"display":{"title":"Depletion of CMOS pixel sensors : studies, characterization, and applications","abstract":"Une architecture de capteurs à pixels CMOS permettant la désertion du volume sensible par polarisation via la face avant du circuit est étudiée à travers la caractérisation en laboratoire d’un capteur prototype. Les performances de collection de charge confirment la désertion d‘une grande partie de l’épaisseur sensible. De plus, le bruit de lecture restant modeste, le capteur présente une excellente résolution en énergie pour les photons en dessous de 20 keV à des températures positives. Ces résultats soulignent l’intérêt de cette architecture pour la spectroscopie des rayons X mous et pour la trajectométrie des particules chargées en milieu très radiatif. La profondeur sur laquelle le capteur est déserté est prédite par un modèle analytique simplifié et par des calculs par éléments finis. Une méthode d’évaluation de cette profondeur par mesure indirecte est proposée. Les mesures corroborent les prédictions concernant un substrat fin, très résistif, qui est intégralement déserté et un substrat moins résistif et mesurant 40 micromètres, qui est partiellement déserté sur 18 micromètres mais détecte correctement sur la totalité de l’épaisseur. Deux développements de capteurs destinés à l’imagerie X et à la neuro-imagerie intracérébrale sur des rats éveillés et libres de leurs mouvements sont présentés.","abstract_html":"Une architecture de capteurs à pixels CMOS permettant la désertion du volume sensible par polarisation via la face avant du circuit est étudiée à travers la caractérisation en laboratoire d’un capteur prototype. Les performances de collection de charge confirment la désertion d‘une grande partie de l’épaisseur sensible. De plus, le bruit de lecture restant modeste, le capteur présente une excellente résolution en énergie pour les photons en dessous de 20 keV à des températures positives. Ces résultats soulignent l’intérêt de cette architecture pour la spectroscopie des rayons X mous et pour la trajectométrie des particules chargées en milieu très radiatif. La profondeur sur laquelle le capteur est déserté est prédite par un modèle analytique simplifié et par des calculs par éléments finis. Une méthode d’évaluation de cette profondeur par mesure indirecte est proposée. Les mesures corroborent les prédictions concernant un substrat fin, très résistif, qui est intégralement déserté et un substrat moins résistif et mesurant 40 micromètres, qui est partiellement déserté sur 18 micromètres mais détecte correctement sur la totalité de l’épaisseur. Deux développements de capteurs destinés à l’imagerie X et à la neuro-imagerie intracérébrale sur des rats éveillés et libres de leurs mouvements sont présentés.","abstract_has_math":false,"creators":["Heymes, Julian"],"institution":"Strasbourg","degree_name":"Docteur es","degree_level":"Doctorat","degree_discipline":"Physique","degree_department":null,"school":null,"contributors":["Strasbourg"],"advisors":["Baudot, Jérôme"],"committee_chairs":["Hébrard, Luc"],"committee_members":["Riedler, Petra","Wunderer, Cornelia"],"year":2019,"date_issued":"2019-12-31","date_published":"2019-12-31","updated_at":"2026-11-27T06:57:00Z","subjects":["Détecteurs semi-conducteur","Capteur à pixels CMOS","Désertion","Développement de capteur","Radiotolérance","Spectroscopie","Semiconductor Detectors","CMOS pixel sensors","Depletion","Sensor development","Radiation hardness","Spectroscopy","539.7"],"languages":["en","fr"],"rights":["Open Access"],"rights_urls":["http://purl.org/eprint/accessRights/OpenAccess"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2018STRAE010","https://theses.hal.science/tel-01998288","http://www.theses.fr/2018STRAE010/abes"],"render_values":[{"text":"https://theses.fr/2018STRAE010","href":"https://theses.fr/2018STRAE010","code":true},{"text":"https://theses.hal.science/tel-01998288","href":"https://theses.hal.science/tel-01998288","code":true},{"text":"http://www.theses.fr/2018STRAE010/abes","href":"http://www.theses.fr/2018STRAE010/abes","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2018STRAE010/document"],"render_values":[{"text":"http://www.theses.fr/2018STRAE010/document","href":"http://www.theses.fr/2018STRAE010/document","code":true}]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["https://www.idref.fr/157760502","93777"],"render_values":[{"text":"https://www.idref.fr/157760502","href":"https://www.idref.fr/157760502","code":true},{"text":"93777","href":null,"code":true}]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["https://www.idref.fr/156500019"],"render_values":[{"text":"https://www.idref.fr/156500019","href":"https://www.idref.fr/156500019","code":true}]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/131056549"],"render_values":[{"text":"https://www.idref.fr/131056549","href":"https://www.idref.fr/131056549","code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2018STRAE010"],"render_values":[{"text":"2018STRAE010","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/231195214","https://www.idref.fr/151229856","https://www.idref.fr/11193429X","https://www.idref.fr/19351060X","https://www.idref.fr/191241903","https://www.idref.fr/233574778","https://www.idref.fr/233574638"],"render_values":[{"text":"https://www.idref.fr/231195214","href":"https://www.idref.fr/231195214","code":true},{"text":"https://www.idref.fr/151229856","href":"https://www.idref.fr/151229856","code":true},{"text":"https://www.idref.fr/11193429X","href":"https://www.idref.fr/11193429X","code":true},{"text":"https://www.idref.fr/19351060X","href":"https://www.idref.fr/19351060X","code":true},{"text":"https://www.idref.fr/191241903","href":"https://www.idref.fr/191241903","code":true},{"text":"https://www.idref.fr/233574778","href":"https://www.idref.fr/233574778","code":true},{"text":"https://www.idref.fr/233574638","href":"https://www.idref.fr/233574638","code":true}]}]},"links":{"outbound_url":"https://doi.org/10.70675/edd0b2ebz3f11z433bz9337ze5b040deba80","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.70675/edd0b2ebz3f11z433bz9337ze5b040deba80","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astar-france%3A2018STRAE010","prefix":"oai_dc"},"source_record":{"url":"https://staroai.theses.fr/OAIHandler?verb=GetRecord&metadataPrefix=tef&identifier=2018STRAE010","prefix":"tef"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Strasbourg","Baudot, Jérôme"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Baudot, Jérôme"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Hébrard, Luc"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Riedler, Petra","Wunderer, Cornelia"]},{"key":"dc:contributor.examiner","label":"Dc Contributor Examiner","values":["Barbero, Marlon","Stefanov, Konstantin"]},{"key":"dc:contributor.researchpartner","label":"Dc Contributor Researchpartner","values":["Institut pluridisciplinaire Hubert Curien (Strasbourg ; 2006-....)"]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["https://www.idref.fr/157760502","93777"]},{"key":"dc:creator","label":"Author","values":["Heymes, Julian"]},{"key":"person:birthdate","label":"Person Birthdate","values":["1989-11-09"]},{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/231195214","https://www.idref.fr/151229856","https://www.idref.fr/11193429X","https://www.idref.fr/19351060X","https://www.idref.fr/191241903","https://www.idref.fr/233574778","https://www.idref.fr/233574638"]},{"key":"person:nationality","label":"Person Nationality","values":["FR"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-07-17"]},{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2018-07-17"]},{"key":"dc:date.issued","label":"Date","values":["2019-12-31"]},{"key":"dc:publisher","label":"Institution","values":["Université de Strasbourg"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Strasbourg"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation","Text"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:by_published_works","label":"Thesis By Published Works","values":["non"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physique"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctorat"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Docteur es"]},{"key":"thesis:doctoral_school","label":"Thesis Doctoral School","values":["École doctorale Physique et chimie-physique (Strasbourg ; 1994-....)"]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["https://www.idref.fr/156500019"]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/131056549"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Strasbourg"]},{"key":"thesis:jury_release_opinion","label":"Thesis Jury Release Opinion","values":["oui"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2018STRAE010"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Détecteurs semi-conducteur","Capteur à pixels CMOS","Désertion","Développement de capteur","Radiotolérance","Spectroscopie","Semiconductor Detectors","CMOS pixel sensors","Depletion","Sensor development","Radiation hardness","Spectroscopy","539.7"]},{"key":"dc:subject.ddc","label":"Dc Subject Ddc","values":["539.7"]},{"key":"dc:subject.rameau","label":"Dc Subject Rameau","values":["Capteurs d'images CMOS","Détecteurs à semiconducteurs","Spectroscopie des rayons X"]},{"key":"dc:subject.uri","label":"Dc Subject URI","values":["https://www.idref.fr/16399353X","https://www.idref.fr/031685544","https://www.idref.fr/027504417"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","fr"]},{"key":"dc:language.rfc3066","label":"Language (RFC 3066)","values":["en","fr"]},{"key":"dc:rights","label":"Dc Rights","values":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"]},{"key":"dc:rights.permissions","label":"Dc Rights Permissions","values":["display, duplicate, print"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2018STRAE010/document"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.70675/edd0b2ebz3f11z433bz9337ze5b040deba80"]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["STRA/THESE_108960/document/0/0/Heymes_Julian_2018_ED182_A.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2018STRAE010","https://theses.hal.science/tel-01998288","http://www.theses.fr/2018STRAE010/abes"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Une architecture de capteurs à pixels CMOS permettant la désertion du volume sensible par polarisation via la face avant du circuit est étudiée à travers la caractérisation en laboratoire d’un capteur prototype. Les performances de collection de charge confirment la désertion d‘une grande partie de l’épaisseur sensible. De plus, le bruit de lecture restant modeste, le capteur présente une excellente résolution en énergie pour les photons en dessous de 20 keV à des températures positives. Ces résultats soulignent l’intérêt de cette architecture pour la spectroscopie des rayons X mous et pour la trajectométrie des particules chargées en milieu très radiatif. La profondeur sur laquelle le capteur est déserté est prédite par un modèle analytique simplifié et par des calculs par éléments finis. Une méthode d’évaluation de cette profondeur par mesure indirecte est proposée. Les mesures corroborent les prédictions concernant un substrat fin, très résistif, qui est intégralement déserté et un substrat moins résistif et mesurant 40 micromètres, qui est partiellement déserté sur 18 micromètres mais détecte correctement sur la totalité de l’épaisseur. Deux développements de capteurs destinés à l’imagerie X et à la neuro-imagerie intracérébrale sur des rats éveillés et libres de leurs mouvements sont présentés.","An architecture of CMOS pixel sensor allowing the depletion of the sensitive volume through frontside biasing is studied through the characterization in laboratory of a prototype. The charge collection performances confirm the depletion of a large part of the sensitive thickness. In addition, with a modest noise level, the sensor features an excellent energy resolution for photons below 20 keV at positive temperatures. These results demonstrate that such sensors are suited for soft X-ray spectroscopy and for charged particle tracking in highly radiative environment. A simplified analytical model and finite elements calculus are used to predict the depletion depth reached. An indirect measurement method to evaluate this depth is proposed. Measurements confirm predictions for a thin highly resistive epitaxial layer, which is fully depleted, and a 40micrometers thick bulk less resistive substrate, for which depletion reached 18 micrometers but which still offers correct detection over its full depth. Two sensor designs dedicated to X-ray imaging and in-brain neuroimaging on awake and freely moving rats are presented."]},{"key":"dc:description.abstract","label":"Abstract","values":["Une architecture de capteurs à pixels CMOS permettant la désertion du volume sensible par polarisation via la face avant du circuit est étudiée à travers la caractérisation en laboratoire d’un capteur prototype. Les performances de collection de charge confirment la désertion d‘une grande partie de l’épaisseur sensible. De plus, le bruit de lecture restant modeste, le capteur présente une excellente résolution en énergie pour les photons en dessous de 20 keV à des températures positives. Ces résultats soulignent l’intérêt de cette architecture pour la spectroscopie des rayons X mous et pour la trajectométrie des particules chargées en milieu très radiatif. La profondeur sur laquelle le capteur est déserté est prédite par un modèle analytique simplifié et par des calculs par éléments finis. Une méthode d’évaluation de cette profondeur par mesure indirecte est proposée. Les mesures corroborent les prédictions concernant un substrat fin, très résistif, qui est intégralement déserté et un substrat moins résistif et mesurant 40 micromètres, qui est partiellement déserté sur 18 micromètres mais détecte correctement sur la totalité de l’épaisseur. Deux développements de capteurs destinés à l’imagerie X et à la neuro-imagerie intracérébrale sur des rats éveillés et libres de leurs mouvements sont présentés.","An architecture of CMOS pixel sensor allowing the depletion of the sensitive volume through frontside biasing is studied through the characterization in laboratory of a prototype. The charge collection performances confirm the depletion of a large part of the sensitive thickness. In addition, with a modest noise level, the sensor features an excellent energy resolution for photons below 20 keV at positive temperatures. These results demonstrate that such sensors are suited for soft X-ray spectroscopy and for charged particle tracking in highly radiative environment. A simplified analytical model and finite elements calculus are used to predict the depletion depth reached. An indirect measurement method to evaluate this depth is proposed. Measurements confirm predictions for a thin highly resistive epitaxial layer, which is fully depleted, and a 40micrometers thick bulk less resistive substrate, for which depletion reached 18 micrometers but which still offers correct detection over its full depth. Two sensor designs dedicated to X-ray imaging and in-brain neuroimaging on awake and freely moving rats are presented."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["9424988","9351333"]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["PDF"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["PDF","application/pdf"]},{"key":"dc:title","label":"Title","values":["Depletion of CMOS pixel sensors : studies, characterization, and applications","Désertion de capteurs à pixels CMOS : étude, caractérisations et applications"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Désertion de capteurs à pixels CMOS : étude, caractérisations et applications"]},{"key":"tef:authorizedname","label":"Tef Authorizedname","values":["Baudot, Jérôme","École doctorale Physique et chimie-physique (Strasbourg ; 1994-....)","Hebrard, Luc","Institut pluridisciplinaire Hubert Curien (Strasbourg)","Riedler, Petra","Wunderer, Cornelia","Barbero, Marlon","Stefanov, Konstantin"]},{"key":"tef:internalref","label":"Tef Internalref","values":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2"]},{"key":"tef:oaisetspec","label":"Tef Oaisetspec","values":["ddc:530"]},{"key":"tef:record.agent","label":"Tef Record Agent","values":["ABES"]},{"key":"tef:record.agentnote","label":"Tef Record Agentnote","values":["Note"]},{"key":"tef:record.created","label":"Tef Record Created","values":["2018-08-23T15:18:04"]},{"key":"tef:record.modified","label":"Tef Record Modified","values":["2026-03-11T03:11:22Z"]},{"key":"tef:record.status","label":"Tef Record Status","values":["valide"]}]}],"canonical_facts":{"dc:contributor":["Strasbourg","Baudot, Jérôme"],"dc:contributor.advisor":["Baudot, Jérôme"],"dc:contributor.committeechair":["Hébrard, Luc"],"dc:contributor.committeemember":["Riedler, Petra","Wunderer, Cornelia"],"dc:contributor.examiner":["Barbero, Marlon","Stefanov, Konstantin"],"dc:contributor.researchpartner":["Institut pluridisciplinaire Hubert Curien (Strasbourg ; 2006-....)"],"dc:contributor.researchpartner.identifier":["https://www.idref.fr/157760502","93777"],"dc:creator":["Heymes, Julian"],"dc:date":["2018-07-17"],"dc:date.dateaccepted":["2018-07-17"],"dc:date.issued":["2019-12-31"],"dc:description":["Une architecture de capteurs à pixels CMOS permettant la désertion du volume sensible par polarisation via la face avant du circuit est étudiée à travers la caractérisation en laboratoire d’un capteur prototype. Les performances de collection de charge confirment la désertion d‘une grande partie de l’épaisseur sensible. De plus, le bruit de lecture restant modeste, le capteur présente une excellente résolution en énergie pour les photons en dessous de 20 keV à des températures positives. Ces résultats soulignent l’intérêt de cette architecture pour la spectroscopie des rayons X mous et pour la trajectométrie des particules chargées en milieu très radiatif. La profondeur sur laquelle le capteur est déserté est prédite par un modèle analytique simplifié et par des calculs par éléments finis. Une méthode d’évaluation de cette profondeur par mesure indirecte est proposée. Les mesures corroborent les prédictions concernant un substrat fin, très résistif, qui est intégralement déserté et un substrat moins résistif et mesurant 40 micromètres, qui est partiellement déserté sur 18 micromètres mais détecte correctement sur la totalité de l’épaisseur. Deux développements de capteurs destinés à l’imagerie X et à la neuro-imagerie intracérébrale sur des rats éveillés et libres de leurs mouvements sont présentés.","An architecture of CMOS pixel sensor allowing the depletion of the sensitive volume through frontside biasing is studied through the characterization in laboratory of a prototype. The charge collection performances confirm the depletion of a large part of the sensitive thickness. In addition, with a modest noise level, the sensor features an excellent energy resolution for photons below 20 keV at positive temperatures. These results demonstrate that such sensors are suited for soft X-ray spectroscopy and for charged particle tracking in highly radiative environment. A simplified analytical model and finite elements calculus are used to predict the depletion depth reached. An indirect measurement method to evaluate this depth is proposed. Measurements confirm predictions for a thin highly resistive epitaxial layer, which is fully depleted, and a 40micrometers thick bulk less resistive substrate, for which depletion reached 18 micrometers but which still offers correct detection over its full depth. Two sensor designs dedicated to X-ray imaging and in-brain neuroimaging on awake and freely moving rats are presented."],"dc:description.abstract":["Une architecture de capteurs à pixels CMOS permettant la désertion du volume sensible par polarisation via la face avant du circuit est étudiée à travers la caractérisation en laboratoire d’un capteur prototype. Les performances de collection de charge confirment la désertion d‘une grande partie de l’épaisseur sensible. De plus, le bruit de lecture restant modeste, le capteur présente une excellente résolution en énergie pour les photons en dessous de 20 keV à des températures positives. Ces résultats soulignent l’intérêt de cette architecture pour la spectroscopie des rayons X mous et pour la trajectométrie des particules chargées en milieu très radiatif. La profondeur sur laquelle le capteur est déserté est prédite par un modèle analytique simplifié et par des calculs par éléments finis. Une méthode d’évaluation de cette profondeur par mesure indirecte est proposée. Les mesures corroborent les prédictions concernant un substrat fin, très résistif, qui est intégralement déserté et un substrat moins résistif et mesurant 40 micromètres, qui est partiellement déserté sur 18 micromètres mais détecte correctement sur la totalité de l’épaisseur. Deux développements de capteurs destinés à l’imagerie X et à la neuro-imagerie intracérébrale sur des rats éveillés et libres de leurs mouvements sont présentés.","An architecture of CMOS pixel sensor allowing the depletion of the sensitive volume through frontside biasing is studied through the characterization in laboratory of a prototype. The charge collection performances confirm the depletion of a large part of the sensitive thickness. In addition, with a modest noise level, the sensor features an excellent energy resolution for photons below 20 keV at positive temperatures. These results demonstrate that such sensors are suited for soft X-ray spectroscopy and for charged particle tracking in highly radiative environment. A simplified analytical model and finite elements calculus are used to predict the depletion depth reached. An indirect measurement method to evaluate this depth is proposed. Measurements confirm predictions for a thin highly resistive epitaxial layer, which is fully depleted, and a 40micrometers thick bulk less resistive substrate, for which depletion reached 18 micrometers but which still offers correct detection over its full depth. Two sensor designs dedicated to X-ray imaging and in-brain neuroimaging on awake and freely moving rats are presented."],"dc:format.extent":["9424988","9351333"],"dc:format.filetype":["PDF"],"dc:format.medium":["PDF","application/pdf"],"dc:identifier":["http://www.theses.fr/2018STRAE010/document"],"dc:identifier.doi":["https://doi.org/10.70675/edd0b2ebz3f11z433bz9337ze5b040deba80"],"dc:identifier.fulltext":["STRA/THESE_108960/document/0/0/Heymes_Julian_2018_ED182_A.pdf"],"dc:identifier.uri":["https://theses.fr/2018STRAE010","https://theses.hal.science/tel-01998288","http://www.theses.fr/2018STRAE010/abes"],"dc:language":["en","fr"],"dc:language.rfc3066":["en","fr"],"dc:publisher":["Université de Strasbourg"],"dc:publisher.place":["Strasbourg"],"dc:rights":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"],"dc:rights.permissions":["display, duplicate, print"],"dc:subject":["Détecteurs semi-conducteur","Capteur à pixels CMOS","Désertion","Développement de capteur","Radiotolérance","Spectroscopie","Semiconductor Detectors","CMOS pixel sensors","Depletion","Sensor development","Radiation hardness","Spectroscopy","539.7"],"dc:subject.ddc":["539.7"],"dc:subject.rameau":["Capteurs d'images CMOS","Détecteurs à semiconducteurs","Spectroscopie des rayons X"],"dc:subject.uri":["https://www.idref.fr/16399353X","https://www.idref.fr/031685544","https://www.idref.fr/027504417"],"dc:title":["Depletion of CMOS pixel sensors : studies, characterization, and applications","Désertion de capteurs à pixels CMOS : étude, caractérisations et applications"],"dc:title.alternative":["Désertion de capteurs à pixels CMOS : étude, caractérisations et applications"],"dc:type":["Electronic Thesis or Dissertation","Text"],"dc:type.dcmitype":["Text"],"person:birthdate":["1989-11-09"],"person:identifier.idref":["https://www.idref.fr/231195214","https://www.idref.fr/151229856","https://www.idref.fr/11193429X","https://www.idref.fr/19351060X","https://www.idref.fr/191241903","https://www.idref.fr/233574778","https://www.idref.fr/233574638"],"person:nationality":["FR"],"tef:authorizedname":["Baudot, Jérôme","École doctorale Physique et chimie-physique (Strasbourg ; 1994-....)","Hebrard, Luc","Institut pluridisciplinaire Hubert Curien (Strasbourg)","Riedler, Petra","Wunderer, Cornelia","Barbero, Marlon","Stefanov, Konstantin"],"tef:internalref":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2"],"tef:oaisetspec":["ddc:530"],"tef:record.agent":["ABES"],"tef:record.agentnote":["Note"],"tef:record.created":["2018-08-23T15:18:04"],"tef:record.modified":["2026-03-11T03:11:22Z"],"tef:record.status":["valide"],"thesis:by_published_works":["non"],"thesis:degree_discipline":["Physique"],"thesis:degree_level":["Doctorat"],"thesis:degree_name":["Docteur es"],"thesis:doctoral_school":["École doctorale Physique et chimie-physique (Strasbourg ; 1994-....)"],"thesis:doctoral_school_identifier":["https://www.idref.fr/156500019"],"thesis:institution_identifier":["https://www.idref.fr/131056549"],"thesis:institution_name":["Strasbourg"],"thesis:jury_release_opinion":["oui"],"thesis:thesis_identifier":["2018STRAE010"]},"updated_at":"2026-11-27T06:57:00Z"}