{"id":{"repo_id":"star-france","oai_identifier":"2021MONTS024"},"canonical_url":"https://search.ndltd.org/etd/star-france/2021MONTS024","repository":{"repo_id":"star-france","name":"STAR","base_url":"https://staroai.theses.fr/OAIHandler"},"display":{"title":"Conception et commande de mécanismes de tenségrité pour des applications en radiologie interventionnelle","abstract":"Ce travail de thèse propose un assistant robotique aux gestes hépatiques percutanés guidés par IRM. L'objectif principal pour cet assistant est de faciliter ces gestes et de satisfaire les différentes contraintes de compatibilité, de légèreté et de compacité imposées par l'environnement IRM. Une exigence supplémentaire pour cet assistant est l'adaptation des mouvements physiologiques de l'organe pendant les cycles respiratoires. La limitation des assistants robotiques de l'état de l'art en matière d'adaptation aux mouvements nous a motivé à proposer dans ce manuscrit l'exploitation des mécanismes de tenségrité et de leurs propriétés inhérentes de reconfiguration et de variation de raideur afin de surmonter les divers défis de conception.Nos contributions incluent la conception, la modélisation et la commande des mécanismes de tenségrité. Deux approches de commande pour asservir la position et la raideur du dispositif sont introduits. La première approche est basée sur l'implémentation d'un algorithme de gestion coordonnée des tensions des câbles. La deuxième est fondée sur un contrôleur prédictif linéaire. Une validation des performances de suivi de trajectoire et de modulation de raideur est menée sur deux versions de prototype en utilisant les stratégies de commande proposées.","abstract_html":"Ce travail de thèse propose un assistant robotique aux gestes hépatiques percutanés guidés par IRM. L&#x27;objectif principal pour cet assistant est de faciliter ces gestes et de satisfaire les différentes contraintes de compatibilité, de légèreté et de compacité imposées par l&#x27;environnement IRM. Une exigence supplémentaire pour cet assistant est l&#x27;adaptation des mouvements physiologiques de l&#x27;organe pendant les cycles respiratoires. La limitation des assistants robotiques de l&#x27;état de l&#x27;art en matière d&#x27;adaptation aux mouvements nous a motivé à proposer dans ce manuscrit l&#x27;exploitation des mécanismes de tenségrité et de leurs propriétés inhérentes de reconfiguration et de variation de raideur afin de surmonter les divers défis de conception.Nos contributions incluent la conception, la modélisation et la commande des mécanismes de tenségrité. Deux approches de commande pour asservir la position et la raideur du dispositif sont introduits. La première approche est basée sur l&#x27;implémentation d&#x27;un algorithme de gestion coordonnée des tensions des câbles. La deuxième est fondée sur un contrôleur prédictif linéaire. Une validation des performances de suivi de trajectoire et de modulation de raideur est menée sur deux versions de prototype en utilisant les stratégies de commande proposées.","abstract_has_math":false,"creators":["Jurado realpe, Jr Martin"],"institution":"Montpellier","degree_name":"Docteur es","degree_level":"Doctorat","degree_discipline":"SYAM - Systèmes Automatiques et Micro-Électroniques","degree_department":null,"school":null,"contributors":["Montpellier"],"advisors":["Poignet, Philippe"],"committee_chairs":["Wenger, Philippe"],"committee_members":["Poignet, Philippe","Wenger, Philippe","Renaud, Pierre","Morel, Guillaume","Abdelaziz, Salih"],"year":2021,"date_issued":"2021-06-29","date_published":"2021-06-29","updated_at":"2026-11-27T10:01:41Z","subjects":["Radiologie interventionnelle","Irm","Mécanismes de tenségrité","Commande prédictive","Suivi de trajectoire","Raideur variable","Interventional radiology","Mri","Tensegrity mechanisms","Predictive control","Trajectory tracking","Variable stiffness"],"languages":["fr"],"rights":["Open Access"],"rights_urls":["http://purl.org/eprint/accessRights/OpenAccess"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2021MONTS024","https://ged.scdi-montpellier.fr/florabium45/jsp/nnt.jsp?nnt=2021MONTS024","https://theses.hal.science/tel-03589557","https://theses.fr/2021MONTS024/abes"],"render_values":[{"text":"https://theses.fr/2021MONTS024","href":"https://theses.fr/2021MONTS024","code":true},{"text":"https://ged.scdi-montpellier.fr/florabium45/jsp/nnt.jsp?nnt=2021MONTS024","href":"https://ged.scdi-montpellier.fr/florabium45/jsp/nnt.jsp?nnt=2021MONTS024","code":true},{"text":"https://theses.hal.science/tel-03589557","href":"https://theses.hal.science/tel-03589557","code":true},{"text":"https://theses.fr/2021MONTS024/abes","href":"https://theses.fr/2021MONTS024/abes","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2021MONTS024/document"],"render_values":[{"text":"http://www.theses.fr/2021MONTS024/document","href":"http://www.theses.fr/2021MONTS024/document","code":true}]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["181","https://www.idref.fr/03556055X"],"render_values":[{"text":"181","href":null,"code":true},{"text":"https://www.idref.fr/03556055X","href":"https://www.idref.fr/03556055X","code":true}]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["166","https://www.idref.fr/188800972"],"render_values":[{"text":"166","href":null,"code":true},{"text":"https://www.idref.fr/188800972","href":"https://www.idref.fr/188800972","code":true}]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/183316401"],"render_values":[{"text":"https://www.idref.fr/183316401","href":"https://www.idref.fr/183316401","code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2021MONTS024"],"render_values":[{"text":"2021MONTS024","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/257493735","https://www.idref.fr/069051542","https://www.idref.fr/035621621","https://www.idref.fr/075418401","https://www.idref.fr/132243369","https://www.idref.fr/168125226"],"render_values":[{"text":"https://www.idref.fr/257493735","href":"https://www.idref.fr/257493735","code":true},{"text":"https://www.idref.fr/069051542","href":"https://www.idref.fr/069051542","code":true},{"text":"https://www.idref.fr/035621621","href":"https://www.idref.fr/035621621","code":true},{"text":"https://www.idref.fr/075418401","href":"https://www.idref.fr/075418401","code":true},{"text":"https://www.idref.fr/132243369","href":"https://www.idref.fr/132243369","code":true},{"text":"https://www.idref.fr/168125226","href":"https://www.idref.fr/168125226","code":true}]},{"key":"person:identifier.student","label":"Person Identifier Student","values":["03vn2p000l5","94387"],"render_values":[{"text":"03vn2p000l5","href":null,"code":true},{"text":"94387","href":null,"code":true}]}]},"links":{"outbound_url":"https://doi.org/10.70675/52334fb0zbd4fz4100zba4bzae5867ef128e","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.70675/52334fb0zbd4fz4100zba4bzae5867ef128e","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astar-france%3A2021MONTS024","prefix":"oai_dc"},"source_record":{"url":"https://staroai.theses.fr/OAIHandler?verb=GetRecord&metadataPrefix=tef&identifier=2021MONTS024","prefix":"tef"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Montpellier","Poignet, Philippe"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Poignet, Philippe"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Wenger, Philippe"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Poignet, Philippe","Wenger, Philippe","Renaud, Pierre","Morel, Guillaume","Abdelaziz, Salih"]},{"key":"dc:contributor.examiner","label":"Dc Contributor Examiner","values":["Renaud, Pierre","Morel, Guillaume"]},{"key":"dc:contributor.researchpartner","label":"Dc Contributor Researchpartner","values":["Laboratoire d'informatique, de robotique et de micro-électronique (Montpellier ; 1992-....)"]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["181","https://www.idref.fr/03556055X"]},{"key":"dc:creator","label":"Author","values":["Jurado realpe, Jr Martin"]},{"key":"person:birthdate","label":"Person Birthdate","values":["1992-09-18"]},{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/257493735","https://www.idref.fr/069051542","https://www.idref.fr/035621621","https://www.idref.fr/075418401","https://www.idref.fr/132243369","https://www.idref.fr/168125226"]},{"key":"person:identifier.student","label":"Person Identifier Student","values":["03vn2p000l5","94387"]},{"key":"person:nationality","label":"Person Nationality","values":["FR"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-06-29"]},{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2021-06-29"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation","Text"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:by_published_works","label":"Thesis By Published Works","values":["non"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["SYAM - Systèmes Automatiques et Micro-Électroniques"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctorat"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Docteur es"]},{"key":"thesis:doctoral_school","label":"Thesis Doctoral School","values":["École doctorale Information, Structures, Systèmes (Montpellier ; 2015-....)"]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["166","https://www.idref.fr/188800972"]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/183316401"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Montpellier"]},{"key":"thesis:jury_release_opinion","label":"Thesis Jury Release Opinion","values":["oui"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2021MONTS024"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radiologie interventionnelle","Irm","Mécanismes de tenségrité","Commande prédictive","Suivi de trajectoire","Raideur variable","Interventional radiology","Mri","Tensegrity mechanisms","Predictive control","Trajectory tracking","Variable stiffness"]},{"key":"dc:subject.rameau","label":"Dc Subject Rameau","values":["Imagerie par résonance magnétique","Radiologie interventionnelle","Commande prédictive"]},{"key":"dc:subject.uri","label":"Dc Subject URI","values":["https://www.idref.fr/028921011","https://www.idref.fr/031412416","https://www.idref.fr/033230331"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["fr"]},{"key":"dc:language.rfc3066","label":"Language (RFC 3066)","values":["fr"]},{"key":"dc:rights","label":"Dc Rights","values":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"]},{"key":"dc:rights.permissions","label":"Dc Rights Permissions","values":["copy, display, duplicate, print"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2021MONTS024/document"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.70675/52334fb0zbd4fz4100zba4bzae5867ef128e"]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["MONT/THESE_162049/document/0/0/JURADO_REALPE_2021_archivage.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2021MONTS024","https://ged.scdi-montpellier.fr/florabium45/jsp/nnt.jsp?nnt=2021MONTS024","https://theses.hal.science/tel-03589557","https://theses.fr/2021MONTS024/abes"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ce travail de thèse propose un assistant robotique aux gestes hépatiques percutanés guidés par IRM. L'objectif principal pour cet assistant est de faciliter ces gestes et de satisfaire les différentes contraintes de compatibilité, de légèreté et de compacité imposées par l'environnement IRM. Une exigence supplémentaire pour cet assistant est l'adaptation des mouvements physiologiques de l'organe pendant les cycles respiratoires. La limitation des assistants robotiques de l'état de l'art en matière d'adaptation aux mouvements nous a motivé à proposer dans ce manuscrit l'exploitation des mécanismes de tenségrité et de leurs propriétés inhérentes de reconfiguration et de variation de raideur afin de surmonter les divers défis de conception.Nos contributions incluent la conception, la modélisation et la commande des mécanismes de tenségrité. Deux approches de commande pour asservir la position et la raideur du dispositif sont introduits. La première approche est basée sur l'implémentation d'un algorithme de gestion coordonnée des tensions des câbles. La deuxième est fondée sur un contrôleur prédictif linéaire. Une validation des performances de suivi de trajectoire et de modulation de raideur est menée sur deux versions de prototype en utilisant les stratégies de commande proposées.","This thesis proposes a robotic assistant for MRI-guided percutaneous liver interventions. The main objective for this assistant is to facilitate the surgical procedures and fulfill the constraints of compatibility, lightness and compactness imposed by the MRI environment. An additional requirement for this assistant is its adaptation with the physiological motion of organs produced during the breathing cycle. The limitation of the state-of-the-art robotic assistants to cope with the additional requirement motivated us to propose in this thesis the use of tensegrity mechanisms and their inherent capacity of reconfiguration and stiffness variation in order to overcome the various design challenges.Our contributions include the design, the modeling and the control of tensegrity mechanisms. Two approaches to control the position and the stiffness of the robot are introduced. The first one is based on the implementation of a tension distribution algorithm. The second one is based on a linear model predictive controller. The position tracking and the stiffness modulation performances are evaluated on two versions of the prototype using the proposed control approaches."]},{"key":"dc:description.abstract","label":"Abstract","values":["Ce travail de thèse propose un assistant robotique aux gestes hépatiques percutanés guidés par IRM. L'objectif principal pour cet assistant est de faciliter ces gestes et de satisfaire les différentes contraintes de compatibilité, de légèreté et de compacité imposées par l'environnement IRM. Une exigence supplémentaire pour cet assistant est l'adaptation des mouvements physiologiques de l'organe pendant les cycles respiratoires. La limitation des assistants robotiques de l'état de l'art en matière d'adaptation aux mouvements nous a motivé à proposer dans ce manuscrit l'exploitation des mécanismes de tenségrité et de leurs propriétés inhérentes de reconfiguration et de variation de raideur afin de surmonter les divers défis de conception.Nos contributions incluent la conception, la modélisation et la commande des mécanismes de tenségrité. Deux approches de commande pour asservir la position et la raideur du dispositif sont introduits. La première approche est basée sur l'implémentation d'un algorithme de gestion coordonnée des tensions des câbles. La deuxième est fondée sur un contrôleur prédictif linéaire. Une validation des performances de suivi de trajectoire et de modulation de raideur est menée sur deux versions de prototype en utilisant les stratégies de commande proposées.","This thesis proposes a robotic assistant for MRI-guided percutaneous liver interventions. The main objective for this assistant is to facilitate the surgical procedures and fulfill the constraints of compatibility, lightness and compactness imposed by the MRI environment. An additional requirement for this assistant is its adaptation with the physiological motion of organs produced during the breathing cycle. The limitation of the state-of-the-art robotic assistants to cope with the additional requirement motivated us to propose in this thesis the use of tensegrity mechanisms and their inherent capacity of reconfiguration and stiffness variation in order to overcome the various design challenges.Our contributions include the design, the modeling and the control of tensegrity mechanisms. Two approaches to control the position and the stiffness of the robot are introduced. The first one is based on the implementation of a tension distribution algorithm. The second one is based on a linear model predictive controller. The position tracking and the stiffness modulation performances are evaluated on two versions of the prototype using the proposed control approaches."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["15654700"]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["PDF"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["PDF"]},{"key":"dc:title","label":"Title","values":["Conception et commande de mécanismes de tenségrité pour des applications en radiologie interventionnelle","Design and control of tensegrity mechanisms for interventional radiology applications"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Design and control of tensegrity mechanisms for interventional radiology applications"]},{"key":"tef:authorizedname","label":"Tef Authorizedname","values":["Poignet, Philippe","École Doctorale Information, Structures, Systèmes","Wenger, Philippe","Laboratoire d'informatique, de robotique et de micro-électronique (Montpellier ; 199.-....)","Renaud, Pierre","Morel, Guillaume","Abdelaziz, Salih"]},{"key":"tef:internalref","label":"Tef Internalref","values":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2","MADS_MEMBRE_DU_JURY_3","MADS_MEMBRE_DU_JURY_4","MADS_MEMBRE_DU_JURY_5"]},{"key":"tef:oaisetspec","label":"Tef Oaisetspec","values":["ddc:004"]},{"key":"tef:record.agent","label":"Tef Record Agent","values":["ABES"]},{"key":"tef:record.agentnote","label":"Tef Record Agentnote","values":["Note"]},{"key":"tef:record.created","label":"Tef Record Created","values":["2021-06-24T09:26:08"]},{"key":"tef:record.modified","label":"Tef Record Modified","values":["2024-04-13T03:39:08Z"]},{"key":"tef:record.status","label":"Tef Record Status","values":["valide"]}]}],"canonical_facts":{"dc:contributor":["Montpellier","Poignet, Philippe"],"dc:contributor.advisor":["Poignet, Philippe"],"dc:contributor.committeechair":["Wenger, Philippe"],"dc:contributor.committeemember":["Poignet, Philippe","Wenger, Philippe","Renaud, Pierre","Morel, Guillaume","Abdelaziz, Salih"],"dc:contributor.examiner":["Renaud, Pierre","Morel, Guillaume"],"dc:contributor.researchpartner":["Laboratoire d'informatique, de robotique et de micro-électronique (Montpellier ; 1992-....)"],"dc:contributor.researchpartner.identifier":["181","https://www.idref.fr/03556055X"],"dc:creator":["Jurado realpe, Jr Martin"],"dc:date":["2021-06-29"],"dc:date.dateaccepted":["2021-06-29"],"dc:description":["Ce travail de thèse propose un assistant robotique aux gestes hépatiques percutanés guidés par IRM. L'objectif principal pour cet assistant est de faciliter ces gestes et de satisfaire les différentes contraintes de compatibilité, de légèreté et de compacité imposées par l'environnement IRM. Une exigence supplémentaire pour cet assistant est l'adaptation des mouvements physiologiques de l'organe pendant les cycles respiratoires. La limitation des assistants robotiques de l'état de l'art en matière d'adaptation aux mouvements nous a motivé à proposer dans ce manuscrit l'exploitation des mécanismes de tenségrité et de leurs propriétés inhérentes de reconfiguration et de variation de raideur afin de surmonter les divers défis de conception.Nos contributions incluent la conception, la modélisation et la commande des mécanismes de tenségrité. Deux approches de commande pour asservir la position et la raideur du dispositif sont introduits. La première approche est basée sur l'implémentation d'un algorithme de gestion coordonnée des tensions des câbles. La deuxième est fondée sur un contrôleur prédictif linéaire. Une validation des performances de suivi de trajectoire et de modulation de raideur est menée sur deux versions de prototype en utilisant les stratégies de commande proposées.","This thesis proposes a robotic assistant for MRI-guided percutaneous liver interventions. The main objective for this assistant is to facilitate the surgical procedures and fulfill the constraints of compatibility, lightness and compactness imposed by the MRI environment. An additional requirement for this assistant is its adaptation with the physiological motion of organs produced during the breathing cycle. The limitation of the state-of-the-art robotic assistants to cope with the additional requirement motivated us to propose in this thesis the use of tensegrity mechanisms and their inherent capacity of reconfiguration and stiffness variation in order to overcome the various design challenges.Our contributions include the design, the modeling and the control of tensegrity mechanisms. Two approaches to control the position and the stiffness of the robot are introduced. The first one is based on the implementation of a tension distribution algorithm. The second one is based on a linear model predictive controller. The position tracking and the stiffness modulation performances are evaluated on two versions of the prototype using the proposed control approaches."],"dc:description.abstract":["Ce travail de thèse propose un assistant robotique aux gestes hépatiques percutanés guidés par IRM. L'objectif principal pour cet assistant est de faciliter ces gestes et de satisfaire les différentes contraintes de compatibilité, de légèreté et de compacité imposées par l'environnement IRM. Une exigence supplémentaire pour cet assistant est l'adaptation des mouvements physiologiques de l'organe pendant les cycles respiratoires. La limitation des assistants robotiques de l'état de l'art en matière d'adaptation aux mouvements nous a motivé à proposer dans ce manuscrit l'exploitation des mécanismes de tenségrité et de leurs propriétés inhérentes de reconfiguration et de variation de raideur afin de surmonter les divers défis de conception.Nos contributions incluent la conception, la modélisation et la commande des mécanismes de tenségrité. Deux approches de commande pour asservir la position et la raideur du dispositif sont introduits. La première approche est basée sur l'implémentation d'un algorithme de gestion coordonnée des tensions des câbles. La deuxième est fondée sur un contrôleur prédictif linéaire. Une validation des performances de suivi de trajectoire et de modulation de raideur est menée sur deux versions de prototype en utilisant les stratégies de commande proposées.","This thesis proposes a robotic assistant for MRI-guided percutaneous liver interventions. The main objective for this assistant is to facilitate the surgical procedures and fulfill the constraints of compatibility, lightness and compactness imposed by the MRI environment. An additional requirement for this assistant is its adaptation with the physiological motion of organs produced during the breathing cycle. The limitation of the state-of-the-art robotic assistants to cope with the additional requirement motivated us to propose in this thesis the use of tensegrity mechanisms and their inherent capacity of reconfiguration and stiffness variation in order to overcome the various design challenges.Our contributions include the design, the modeling and the control of tensegrity mechanisms. Two approaches to control the position and the stiffness of the robot are introduced. The first one is based on the implementation of a tension distribution algorithm. The second one is based on a linear model predictive controller. The position tracking and the stiffness modulation performances are evaluated on two versions of the prototype using the proposed control approaches."],"dc:format.extent":["15654700"],"dc:format.filetype":["PDF"],"dc:format.medium":["PDF"],"dc:identifier":["http://www.theses.fr/2021MONTS024/document"],"dc:identifier.doi":["https://doi.org/10.70675/52334fb0zbd4fz4100zba4bzae5867ef128e"],"dc:identifier.fulltext":["MONT/THESE_162049/document/0/0/JURADO_REALPE_2021_archivage.pdf"],"dc:identifier.uri":["https://theses.fr/2021MONTS024","https://ged.scdi-montpellier.fr/florabium45/jsp/nnt.jsp?nnt=2021MONTS024","https://theses.hal.science/tel-03589557","https://theses.fr/2021MONTS024/abes"],"dc:language":["fr"],"dc:language.rfc3066":["fr"],"dc:rights":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"],"dc:rights.permissions":["copy, display, duplicate, print"],"dc:subject":["Radiologie interventionnelle","Irm","Mécanismes de tenségrité","Commande prédictive","Suivi de trajectoire","Raideur variable","Interventional radiology","Mri","Tensegrity mechanisms","Predictive control","Trajectory tracking","Variable stiffness"],"dc:subject.rameau":["Imagerie par résonance magnétique","Radiologie interventionnelle","Commande prédictive"],"dc:subject.uri":["https://www.idref.fr/028921011","https://www.idref.fr/031412416","https://www.idref.fr/033230331"],"dc:title":["Conception et commande de mécanismes de tenségrité pour des applications en radiologie interventionnelle","Design and control of tensegrity mechanisms for interventional radiology applications"],"dc:title.alternative":["Design and control of tensegrity mechanisms for interventional radiology applications"],"dc:type":["Electronic Thesis or Dissertation","Text"],"dc:type.dcmitype":["Text"],"person:birthdate":["1992-09-18"],"person:identifier.idref":["https://www.idref.fr/257493735","https://www.idref.fr/069051542","https://www.idref.fr/035621621","https://www.idref.fr/075418401","https://www.idref.fr/132243369","https://www.idref.fr/168125226"],"person:identifier.student":["03vn2p000l5","94387"],"person:nationality":["FR"],"tef:authorizedname":["Poignet, Philippe","École Doctorale Information, Structures, Systèmes","Wenger, Philippe","Laboratoire d'informatique, de robotique et de micro-électronique (Montpellier ; 199.-....)","Renaud, Pierre","Morel, Guillaume","Abdelaziz, Salih"],"tef:internalref":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2","MADS_MEMBRE_DU_JURY_3","MADS_MEMBRE_DU_JURY_4","MADS_MEMBRE_DU_JURY_5"],"tef:oaisetspec":["ddc:004"],"tef:record.agent":["ABES"],"tef:record.agentnote":["Note"],"tef:record.created":["2021-06-24T09:26:08"],"tef:record.modified":["2024-04-13T03:39:08Z"],"tef:record.status":["valide"],"thesis:by_published_works":["non"],"thesis:degree_discipline":["SYAM - Systèmes Automatiques et Micro-Électroniques"],"thesis:degree_level":["Doctorat"],"thesis:degree_name":["Docteur es"],"thesis:doctoral_school":["École doctorale Information, Structures, Systèmes (Montpellier ; 2015-....)"],"thesis:doctoral_school_identifier":["166","https://www.idref.fr/188800972"],"thesis:institution_identifier":["https://www.idref.fr/183316401"],"thesis:institution_name":["Montpellier"],"thesis:jury_release_opinion":["oui"],"thesis:thesis_identifier":["2021MONTS024"]},"updated_at":"2026-11-27T10:01:41Z"}