{"id":{"repo_id":"star-france","oai_identifier":"2022ULILR003"},"canonical_url":"https://search.ndltd.org/etd/star-france/2022ULILR003","repository":{"repo_id":"star-france","name":"STAR","base_url":"https://staroai.theses.fr/OAIHandler"},"display":{"title":"Numerical and experimental investigations of the rheological behavior of foam flow : application to the cleaning of surfaces contaminated by microorganisms in the food industries","abstract":"La caractérisation expérimentale et numérique du comportement rhéologique d'une mousse aqueuse s'écoulant à l'intérieur d'un tuyau horizontal avec et sans singularités (demi-expansion soudaine, et chicane) a été étudiée. Différentes conditions d'écoulement ont été étudiées en faisant varier les qualités de mousse (55-85%), et trois nombres de Reynolds (32, 65, et 97). Les mesures de la pression, de la répartition de la vitesse locale et de la contrariante et de l'épaisseur des films liquides au niveau de la paroi à l'aide respectivement de capteurs de pression, de la PIV, de la polarographie et de la conductimétrie ont montré une réorganisation de la mousse en aval du changement de géométrie, avec un film liquide plus épais au fond du conduit, des bulles de plus grande taille au sommet, ainsi qu'une plus grande fraction de vide de la mousse augmentant de la partie inférieure à la partie supérieure de la section du conduit. En outre, la mousse présenterait un caractère visco-élastique comparable à celui d'un liquide monophasique non newtonien. Des simulations de dynamique des fluides ont été entreprises pour prédire ce comportement rhéologique de la mousse, les deux modèles Herschel-Bulkley et Bingham ont été testés en tenant compte de la présence d'un film liquide sous-jacent au fond du canal. La comparaison entre les résultats expérimentaux et numériques a montré que, quelle que soit la qualité de la mousse, le modèle de Herschel-Bulkley pouvait décrire avec précision le comportement rhéologique de la mousse dans les différentes conditions d'écoulement analysées.Le deuxième objectif était d'étudier la capacité d'un écoulement de mousse humide (qualité de 50%) à nettoyer des surfaces en acier inoxydable contaminées par des micro-organismes. Pour cela, deux types de contamination ont été étudiés, des gouttelettes contenant des spores de Bacillus subtilis (soit hydrophiles Bs PY79 ou hydrophobes Bs PY79 spsA), et des biofilms produits par trois souches de bactéries (Escherichia coli SS2, Bacillus cereus 98/4, et Pseudomonas fluorescens Pf1). Différentes conditions d'écoulement ont été réalisées en faisant varier les contraintes de cisaillement pariétale (2.2 - 13.2 Pa), et la taille des bulles (0.18-0.34 mm) dans un conduit sans changement géométrique, afin d'identifier les mécanismes de libération de la contamination et ainsi mieux contrôler et optimiser le processus de nettoyage. Les résultats montrent que, par rapport au NEP conventionnel, le flux de mousse a éliminé efficacement les spores ainsi que les biofilms. De plus, la combinaison d'une contrainte de cisaillement pariétale élevée et de bulles de petite taille (<0,2 mm) s'est avérée prometteuse pour améliorer l'efficacité du nettoyage des spores. D'autre part, une nette amélioration de l'élimination des biofilms a été observée en augmentant la contrainte de cisaillement pariétale. La caractérisation de la mousse et des phénomènes d'interface a indiqué que des mécanismes tels que la fluctuation des contraintes de cisaillement locales, ou de l'épaisseur du film liquide entre les bulles et la paroi induite par le passage des bulles, l'imbibition de la mousse et le balayage de la contamination dans le film liquide, pourraient participer largement aux mécanismes d'élimination. Enfin, l'étude d'analyse du cycle de vie a démontré que le nettoyage à la mousse peut être une technique appropriée pour réduire la consommation d'eau et d'énergie (7 et 8 fois moins) présentant moins d'impacts environnementaux que les procédés CIP, avec environ 70%. Enfin, le nettoyage à la mousse peut être une méthode alternative, qui peut améliorer l'efficacité et réduire l'impact environnemental.D'autres activités menées au cours de la période de doctorat liées à la conception hygiénique sont présentées en soulignant le rôle des contaminants (spores et biofilms), du matériau (autre que l'acier inoxydable) et de la géométrie (conduits ou conception plus complexe) dans le contrôle de l'hygiène.","abstract_html":"La caractérisation expérimentale et numérique du comportement rhéologique d&#x27;une mousse aqueuse s&#x27;écoulant à l&#x27;intérieur d&#x27;un tuyau horizontal avec et sans singularités (demi-expansion soudaine, et chicane) a été étudiée. Différentes conditions d&#x27;écoulement ont été étudiées en faisant varier les qualités de mousse (55-85%), et trois nombres de Reynolds (32, 65, et 97). Les mesures de la pression, de la répartition de la vitesse locale et de la contrariante et de l&#x27;épaisseur des films liquides au niveau de la paroi à l&#x27;aide respectivement de capteurs de pression, de la PIV, de la polarographie et de la conductimétrie ont montré une réorganisation de la mousse en aval du changement de géométrie, avec un film liquide plus épais au fond du conduit, des bulles de plus grande taille au sommet, ainsi qu&#x27;une plus grande fraction de vide de la mousse augmentant de la partie inférieure à la partie supérieure de la section du conduit. En outre, la mousse présenterait un caractère visco-élastique comparable à celui d&#x27;un liquide monophasique non newtonien. Des simulations de dynamique des fluides ont été entreprises pour prédire ce comportement rhéologique de la mousse, les deux modèles Herschel-Bulkley et Bingham ont été testés en tenant compte de la présence d&#x27;un film liquide sous-jacent au fond du canal. La comparaison entre les résultats expérimentaux et numériques a montré que, quelle que soit la qualité de la mousse, le modèle de Herschel-Bulkley pouvait décrire avec précision le comportement rhéologique de la mousse dans les différentes conditions d&#x27;écoulement analysées.Le deuxième objectif était d&#x27;étudier la capacité d&#x27;un écoulement de mousse humide (qualité de 50%) à nettoyer des surfaces en acier inoxydable contaminées par des micro-organismes. Pour cela, deux types de contamination ont été étudiés, des gouttelettes contenant des spores de Bacillus subtilis (soit hydrophiles Bs PY79 ou hydrophobes Bs PY79 spsA), et des biofilms produits par trois souches de bactéries (Escherichia coli SS2, Bacillus cereus 98/4, et Pseudomonas fluorescens Pf1). Différentes conditions d&#x27;écoulement ont été réalisées en faisant varier les contraintes de cisaillement pariétale (2.2 - 13.2 Pa), et la taille des bulles (0.18-0.34 mm) dans un conduit sans changement géométrique, afin d&#x27;identifier les mécanismes de libération de la contamination et ainsi mieux contrôler et optimiser le processus de nettoyage. Les résultats montrent que, par rapport au NEP conventionnel, le flux de mousse a éliminé efficacement les spores ainsi que les biofilms. De plus, la combinaison d&#x27;une contrainte de cisaillement pariétale élevée et de bulles de petite taille (&lt;0,2 mm) s&#x27;est avérée prometteuse pour améliorer l&#x27;efficacité du nettoyage des spores. D&#x27;autre part, une nette amélioration de l&#x27;élimination des biofilms a été observée en augmentant la contrainte de cisaillement pariétale. La caractérisation de la mousse et des phénomènes d&#x27;interface a indiqué que des mécanismes tels que la fluctuation des contraintes de cisaillement locales, ou de l&#x27;épaisseur du film liquide entre les bulles et la paroi induite par le passage des bulles, l&#x27;imbibition de la mousse et le balayage de la contamination dans le film liquide, pourraient participer largement aux mécanismes d&#x27;élimination. Enfin, l&#x27;étude d&#x27;analyse du cycle de vie a démontré que le nettoyage à la mousse peut être une technique appropriée pour réduire la consommation d&#x27;eau et d&#x27;énergie (7 et 8 fois moins) présentant moins d&#x27;impacts environnementaux que les procédés CIP, avec environ 70%. Enfin, le nettoyage à la mousse peut être une méthode alternative, qui peut améliorer l&#x27;efficacité et réduire l&#x27;impact environnemental.D&#x27;autres activités menées au cours de la période de doctorat liées à la conception hygiénique sont présentées en soulignant le rôle des contaminants (spores et biofilms), du matériau (autre que l&#x27;acier inoxydable) et de la géométrie (conduits ou conception plus complexe) dans le contrôle de l&#x27;hygiène.","abstract_has_math":false,"creators":["Dallagi, Heni"],"institution":"Université de Lille (2022-....)","degree_name":"Docteur es","degree_level":"Doctorat","degree_discipline":"Biotechnologies agroalimentaires, sciences de l'aliment, physiologie","degree_department":null,"school":null,"contributors":["Université de Lille (2022-....)"],"advisors":["Bénézech, Thierry","Aloui, Fethi","Faille, Christine"],"committee_chairs":["Legrand, Jack"],"committee_members":["Sampers, Imca","Duchesne, Alexis","Timmerman, Hein","Fameau, Anne-Laure"],"year":2022,"date_issued":"2022-02-28","date_published":"2022-02-28","updated_at":"2026-11-27T10:06:29Z","subjects":["Nettoyage à la mousse","Foam flow","Rheological behavior","Cleaning-In-Place","CFD","Spores and Biofilms","LCA"],"languages":["en"],"rights":["Open Access"],"rights_urls":["http://purl.org/eprint/accessRights/OpenAccess"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2022ULILR003","https://theses.hal.science/tel-03921788","https://theses.fr/2022ULILR003/abes"],"render_values":[{"text":"https://theses.fr/2022ULILR003","href":"https://theses.fr/2022ULILR003","code":true},{"text":"https://theses.hal.science/tel-03921788","href":"https://theses.hal.science/tel-03921788","code":true},{"text":"https://theses.fr/2022ULILR003/abes","href":"https://theses.fr/2022ULILR003/abes","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2022ULILR003/document"],"render_values":[{"text":"http://www.theses.fr/2022ULILR003/document","href":"http://www.theses.fr/2022ULILR003/document","code":true}]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["1002334","https://www.idref.fr/161609465"],"render_values":[{"text":"1002334","href":null,"code":true},{"text":"https://www.idref.fr/161609465","href":"https://www.idref.fr/161609465","code":true}]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["https://www.idref.fr/148937330"],"render_values":[{"text":"https://www.idref.fr/148937330","href":"https://www.idref.fr/148937330","code":true}]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/259265152"],"render_values":[{"text":"https://www.idref.fr/259265152","href":"https://www.idref.fr/259265152","code":true}]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2022ULILR003"],"render_values":[{"text":"2022ULILR003","href":null,"code":true}]}],"person_identifier_entries":[{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/262791560","https://www.idref.fr/059743131","https://www.idref.fr/060386576","https://www.idref.fr/259909572","https://www.idref.fr/150517955","https://www.idref.fr/188103767","https://www.idref.fr/158357744","https://www.idref.fr/033724415"],"render_values":[{"text":"https://www.idref.fr/262791560","href":"https://www.idref.fr/262791560","code":true},{"text":"https://www.idref.fr/059743131","href":"https://www.idref.fr/059743131","code":true},{"text":"https://www.idref.fr/060386576","href":"https://www.idref.fr/060386576","code":true},{"text":"https://www.idref.fr/259909572","href":"https://www.idref.fr/259909572","code":true},{"text":"https://www.idref.fr/150517955","href":"https://www.idref.fr/150517955","code":true},{"text":"https://www.idref.fr/188103767","href":"https://www.idref.fr/188103767","code":true},{"text":"https://www.idref.fr/158357744","href":"https://www.idref.fr/158357744","code":true},{"text":"https://www.idref.fr/033724415","href":"https://www.idref.fr/033724415","code":true}]}]},"links":{"outbound_url":"https://doi.org/10.70675/2e91c3efzb4e4z4e65z8ea2z38f0495e1fb6","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.70675/2e91c3efzb4e4z4e65z8ea2z38f0495e1fb6","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astar-france%3A2022ULILR003","prefix":"oai_dc"},"source_record":{"url":"https://staroai.theses.fr/OAIHandler?verb=GetRecord&metadataPrefix=tef&identifier=2022ULILR003","prefix":"tef"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Université de Lille (2022-....)","Bénézech, Thierry","Aloui, Fethi","Faille, Christine"]},{"key":"dc:contributor.advisor","label":"Advisor","values":["Bénézech, Thierry","Aloui, Fethi","Faille, Christine"]},{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Legrand, Jack"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Sampers, Imca","Duchesne, Alexis","Timmerman, Hein","Fameau, Anne-Laure"]},{"key":"dc:contributor.examiner","label":"Dc Contributor Examiner","values":["Whitehead, Kathryn","Saint-Jalmes, Arnaud"]},{"key":"dc:contributor.researchpartner","label":"Dc Contributor Researchpartner","values":["Unité Matériaux et Transformations (Lille ; 2010-....)"]},{"key":"dc:contributor.researchpartner.identifier","label":"Dc Contributor Researchpartner Identifier","values":["1002334","https://www.idref.fr/161609465"]},{"key":"dc:creator","label":"Author","values":["Dallagi, Heni"]},{"key":"person:birthdate","label":"Person Birthdate","values":["1993-09-13"]},{"key":"person:identifier.idref","label":"Person Identifier Idref","values":["https://www.idref.fr/262791560","https://www.idref.fr/059743131","https://www.idref.fr/060386576","https://www.idref.fr/259909572","https://www.idref.fr/150517955","https://www.idref.fr/188103767","https://www.idref.fr/158357744","https://www.idref.fr/033724415"]},{"key":"person:name.birth","label":"Person Name Birth","values":["Dallagi"]},{"key":"person:nationality","label":"Person Nationality","values":["FR"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-02-28"]},{"key":"dc:date.dateaccepted","label":"Dc Date Dateaccepted","values":["2022-02-28"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation","Text"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:by_published_works","label":"Thesis By Published Works","values":["oui"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biotechnologies agroalimentaires, sciences de l'aliment, physiologie"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctorat"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Docteur es"]},{"key":"thesis:doctoral_school","label":"Thesis Doctoral School","values":["École doctorale Sciences de la matière, du rayonnement et de l'environnement (Lille ; 1992-....)"]},{"key":"thesis:doctoral_school_identifier","label":"Thesis Doctoral School Identifier","values":["https://www.idref.fr/148937330"]},{"key":"thesis:institution_identifier","label":"Thesis Institution Identifier","values":["https://www.idref.fr/259265152"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Université de Lille (2022-....)"]},{"key":"thesis:jury_release_opinion","label":"Thesis Jury Release Opinion","values":["oui"]},{"key":"thesis:thesis_identifier","label":"Thesis Thesis Identifier","values":["2022ULILR003"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nettoyage à la mousse","Foam flow","Rheological behavior","Cleaning-In-Place","CFD","Spores and Biofilms","LCA"]},{"key":"dc:subject.rameau","label":"Dc Subject Rameau","values":["Mousse (chimie) -- Propriétés mécaniques","Rhéologie -- Modèles mathématiques","Surfaces (technologie) -- Nettoyage","Biofilms","Spores bactériennes","Modélisation CFD","Analyse du cycle de vie"]},{"key":"dc:subject.uri","label":"Dc Subject URI","values":["https://www.idref.fr/031747337","https://www.idref.fr/029208971","https://www.idref.fr/027536394","https://www.idref.fr/027551385","https://www.idref.fr/027355357","https://www.idref.fr/027579999","https://www.idref.fr/031449352","https://www.idref.fr/031380697","https://www.idref.fr/190664126","https://www.idref.fr/16162457X"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:language.rfc3066","label":"Language (RFC 3066)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"]},{"key":"dc:rights.permissions","label":"Dc Rights Permissions","values":["display, duplicate, print"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://www.theses.fr/2022ULILR003/document"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.70675/2e91c3efzb4e4z4e65z8ea2z38f0495e1fb6"]},{"key":"dc:identifier.fulltext","label":"Full Text Identifier","values":["ULIL/THESE_180054/document/0/0/These_DALLAGI_Heni.pdf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://theses.fr/2022ULILR003","https://theses.hal.science/tel-03921788","https://theses.fr/2022ULILR003/abes"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["La caractérisation expérimentale et numérique du comportement rhéologique d'une mousse aqueuse s'écoulant à l'intérieur d'un tuyau horizontal avec et sans singularités (demi-expansion soudaine, et chicane) a été étudiée. Différentes conditions d'écoulement ont été étudiées en faisant varier les qualités de mousse (55-85%), et trois nombres de Reynolds (32, 65, et 97). Les mesures de la pression, de la répartition de la vitesse locale et de la contrariante et de l'épaisseur des films liquides au niveau de la paroi à l'aide respectivement de capteurs de pression, de la PIV, de la polarographie et de la conductimétrie ont montré une réorganisation de la mousse en aval du changement de géométrie, avec un film liquide plus épais au fond du conduit, des bulles de plus grande taille au sommet, ainsi qu'une plus grande fraction de vide de la mousse augmentant de la partie inférieure à la partie supérieure de la section du conduit. En outre, la mousse présenterait un caractère visco-élastique comparable à celui d'un liquide monophasique non newtonien. Des simulations de dynamique des fluides ont été entreprises pour prédire ce comportement rhéologique de la mousse, les deux modèles Herschel-Bulkley et Bingham ont été testés en tenant compte de la présence d'un film liquide sous-jacent au fond du canal. La comparaison entre les résultats expérimentaux et numériques a montré que, quelle que soit la qualité de la mousse, le modèle de Herschel-Bulkley pouvait décrire avec précision le comportement rhéologique de la mousse dans les différentes conditions d'écoulement analysées.Le deuxième objectif était d'étudier la capacité d'un écoulement de mousse humide (qualité de 50%) à nettoyer des surfaces en acier inoxydable contaminées par des micro-organismes. Pour cela, deux types de contamination ont été étudiés, des gouttelettes contenant des spores de Bacillus subtilis (soit hydrophiles Bs PY79 ou hydrophobes Bs PY79 spsA), et des biofilms produits par trois souches de bactéries (Escherichia coli SS2, Bacillus cereus 98/4, et Pseudomonas fluorescens Pf1). Différentes conditions d'écoulement ont été réalisées en faisant varier les contraintes de cisaillement pariétale (2.2 - 13.2 Pa), et la taille des bulles (0.18-0.34 mm) dans un conduit sans changement géométrique, afin d'identifier les mécanismes de libération de la contamination et ainsi mieux contrôler et optimiser le processus de nettoyage. Les résultats montrent que, par rapport au NEP conventionnel, le flux de mousse a éliminé efficacement les spores ainsi que les biofilms. De plus, la combinaison d'une contrainte de cisaillement pariétale élevée et de bulles de petite taille (<0,2 mm) s'est avérée prometteuse pour améliorer l'efficacité du nettoyage des spores. D'autre part, une nette amélioration de l'élimination des biofilms a été observée en augmentant la contrainte de cisaillement pariétale. La caractérisation de la mousse et des phénomènes d'interface a indiqué que des mécanismes tels que la fluctuation des contraintes de cisaillement locales, ou de l'épaisseur du film liquide entre les bulles et la paroi induite par le passage des bulles, l'imbibition de la mousse et le balayage de la contamination dans le film liquide, pourraient participer largement aux mécanismes d'élimination. Enfin, l'étude d'analyse du cycle de vie a démontré que le nettoyage à la mousse peut être une technique appropriée pour réduire la consommation d'eau et d'énergie (7 et 8 fois moins) présentant moins d'impacts environnementaux que les procédés CIP, avec environ 70%. Enfin, le nettoyage à la mousse peut être une méthode alternative, qui peut améliorer l'efficacité et réduire l'impact environnemental.D'autres activités menées au cours de la période de doctorat liées à la conception hygiénique sont présentées en soulignant le rôle des contaminants (spores et biofilms), du matériau (autre que l'acier inoxydable) et de la géométrie (conduits ou conception plus complexe) dans le contrôle de l'hygiène.","In this research, experimental and numerical characterization of the rheological behavior of an aqueous foam flowing inside a horizontal pipe with and without singularities (presence of half-sudden expansion, and a fence) were investigated. Different conditions of foam flow were studied by varying the foam qualities (from 55% to 85%), and three Reynolds numbers (32, 65, and 97). Measurements of the pressure measurements, and at the wall the local velocity repartition and the thickness of the liquid films using respectively pressure sensors, Particle Image Velocimetry, and a conductimetry technique shown a reorganization of the foam downstream the geometry change, with a thicker liquid film at the duct bottom, larger bubble sizes at the top, as well as a larger foam void fraction increased from the bottom to the top part of the duct section. In addition, foam would present a visco-elastic character comparable to a non-Newtonian monophasic liquid. Computational Fluid Dynamics simulations were undertaken to predict this rheological behavior of the foam, the two models Herschel-Bulkley and Bingham were tested taken into account the presence of an underlying liquid film at the bottom of the channel . Comparison between experimental and numerical results showed that regardless of the foam quality, Herschel-Bulkley model could accurately describe the rheological behaviour of the aqueous foam under the different flow conditions analysed.The second target was to investigate the ability of a wet foam flow (quality of 50%) to clean stainless-steel surfaces contaminated by microorganisms. For this purpose, two different contamination patterns were studied, droplets containing Bacillus subtilis spores (either hydrophilic Bs PY79 or hydrophobic Bs PY79 spsA), and biofilms produced by three bacteria strains encountered in food industry production plants (Escherichia coli SS2, Bacillus cereus 98/4, and Pseudomonas fluorescens Pf1). Different flow conditions were performed by varying the wall shear stresses (2.2 - 13.2 Pa), and bubble sizes (0.18-0.34 mm) in a straight duct with no geometrical changes, in order to identify the mechanisms of contamination release and thus better control and optimize the foam cleaning process. Results show that compared to conventional cleaning-in-place, foam flow effectively removed Bs spores as well as Bc-98/4, Ec-SS2, and Pf1 biofilms. Moreover, the combination of high shear stress at the wall and small bubble sizes (<0.2 mm) showed promise for improving the cleaning efficiency of spores. On the other hand, a clear improvement of the biofilm removal was observed when increasing the mean wall shear stress. The characterization of the foam and the interface phenomenons (using polarography, conductimetry, and bubble size analysis methods) indicated that mechanisms such as fluctuation in local wall shear stresses, or in the liquid film thickness between the bubbles and the steel wall induced by bubble passage, foam imbibition, and sweeping of the contamination within the liquid film could participate largely to the removal mechanisms. Finally, the life cycle assessment study demonstrated that foam flow cleaning could be a suitable technique to reduce water and energy consumption (7 and 8 times less, respectively) presenting less environmental impacts than CIP processes, with about 70%. Lastly, foam flow cleaning can be an alternative method, which can improve efficiency and reduce environmental impact. Additional activities conducted during the PhD period related to hygienic design are presented highlighting the role of the contaminants (spores and biofilms), the material (other than stainless steel) and the geometry (ducts or more complex design) in hygiene monitoring."]},{"key":"dc:description.abstract","label":"Abstract","values":["La caractérisation expérimentale et numérique du comportement rhéologique d'une mousse aqueuse s'écoulant à l'intérieur d'un tuyau horizontal avec et sans singularités (demi-expansion soudaine, et chicane) a été étudiée. Différentes conditions d'écoulement ont été étudiées en faisant varier les qualités de mousse (55-85%), et trois nombres de Reynolds (32, 65, et 97). Les mesures de la pression, de la répartition de la vitesse locale et de la contrariante et de l'épaisseur des films liquides au niveau de la paroi à l'aide respectivement de capteurs de pression, de la PIV, de la polarographie et de la conductimétrie ont montré une réorganisation de la mousse en aval du changement de géométrie, avec un film liquide plus épais au fond du conduit, des bulles de plus grande taille au sommet, ainsi qu'une plus grande fraction de vide de la mousse augmentant de la partie inférieure à la partie supérieure de la section du conduit. En outre, la mousse présenterait un caractère visco-élastique comparable à celui d'un liquide monophasique non newtonien. Des simulations de dynamique des fluides ont été entreprises pour prédire ce comportement rhéologique de la mousse, les deux modèles Herschel-Bulkley et Bingham ont été testés en tenant compte de la présence d'un film liquide sous-jacent au fond du canal. La comparaison entre les résultats expérimentaux et numériques a montré que, quelle que soit la qualité de la mousse, le modèle de Herschel-Bulkley pouvait décrire avec précision le comportement rhéologique de la mousse dans les différentes conditions d'écoulement analysées.Le deuxième objectif était d'étudier la capacité d'un écoulement de mousse humide (qualité de 50%) à nettoyer des surfaces en acier inoxydable contaminées par des micro-organismes. Pour cela, deux types de contamination ont été étudiés, des gouttelettes contenant des spores de Bacillus subtilis (soit hydrophiles Bs PY79 ou hydrophobes Bs PY79 spsA), et des biofilms produits par trois souches de bactéries (Escherichia coli SS2, Bacillus cereus 98/4, et Pseudomonas fluorescens Pf1). Différentes conditions d'écoulement ont été réalisées en faisant varier les contraintes de cisaillement pariétale (2.2 - 13.2 Pa), et la taille des bulles (0.18-0.34 mm) dans un conduit sans changement géométrique, afin d'identifier les mécanismes de libération de la contamination et ainsi mieux contrôler et optimiser le processus de nettoyage. Les résultats montrent que, par rapport au NEP conventionnel, le flux de mousse a éliminé efficacement les spores ainsi que les biofilms. De plus, la combinaison d'une contrainte de cisaillement pariétale élevée et de bulles de petite taille (<0,2 mm) s'est avérée prometteuse pour améliorer l'efficacité du nettoyage des spores. D'autre part, une nette amélioration de l'élimination des biofilms a été observée en augmentant la contrainte de cisaillement pariétale. La caractérisation de la mousse et des phénomènes d'interface a indiqué que des mécanismes tels que la fluctuation des contraintes de cisaillement locales, ou de l'épaisseur du film liquide entre les bulles et la paroi induite par le passage des bulles, l'imbibition de la mousse et le balayage de la contamination dans le film liquide, pourraient participer largement aux mécanismes d'élimination. Enfin, l'étude d'analyse du cycle de vie a démontré que le nettoyage à la mousse peut être une technique appropriée pour réduire la consommation d'eau et d'énergie (7 et 8 fois moins) présentant moins d'impacts environnementaux que les procédés CIP, avec environ 70%. Enfin, le nettoyage à la mousse peut être une méthode alternative, qui peut améliorer l'efficacité et réduire l'impact environnemental.D'autres activités menées au cours de la période de doctorat liées à la conception hygiénique sont présentées en soulignant le rôle des contaminants (spores et biofilms), du matériau (autre que l'acier inoxydable) et de la géométrie (conduits ou conception plus complexe) dans le contrôle de l'hygiène.","In this research, experimental and numerical characterization of the rheological behavior of an aqueous foam flowing inside a horizontal pipe with and without singularities (presence of half-sudden expansion, and a fence) were investigated. Different conditions of foam flow were studied by varying the foam qualities (from 55% to 85%), and three Reynolds numbers (32, 65, and 97). Measurements of the pressure measurements, and at the wall the local velocity repartition and the thickness of the liquid films using respectively pressure sensors, Particle Image Velocimetry, and a conductimetry technique shown a reorganization of the foam downstream the geometry change, with a thicker liquid film at the duct bottom, larger bubble sizes at the top, as well as a larger foam void fraction increased from the bottom to the top part of the duct section. In addition, foam would present a visco-elastic character comparable to a non-Newtonian monophasic liquid. Computational Fluid Dynamics simulations were undertaken to predict this rheological behavior of the foam, the two models Herschel-Bulkley and Bingham were tested taken into account the presence of an underlying liquid film at the bottom of the channel . Comparison between experimental and numerical results showed that regardless of the foam quality, Herschel-Bulkley model could accurately describe the rheological behaviour of the aqueous foam under the different flow conditions analysed.The second target was to investigate the ability of a wet foam flow (quality of 50%) to clean stainless-steel surfaces contaminated by microorganisms. For this purpose, two different contamination patterns were studied, droplets containing Bacillus subtilis spores (either hydrophilic Bs PY79 or hydrophobic Bs PY79 spsA), and biofilms produced by three bacteria strains encountered in food industry production plants (Escherichia coli SS2, Bacillus cereus 98/4, and Pseudomonas fluorescens Pf1). Different flow conditions were performed by varying the wall shear stresses (2.2 - 13.2 Pa), and bubble sizes (0.18-0.34 mm) in a straight duct with no geometrical changes, in order to identify the mechanisms of contamination release and thus better control and optimize the foam cleaning process. Results show that compared to conventional cleaning-in-place, foam flow effectively removed Bs spores as well as Bc-98/4, Ec-SS2, and Pf1 biofilms. Moreover, the combination of high shear stress at the wall and small bubble sizes (<0.2 mm) showed promise for improving the cleaning efficiency of spores. On the other hand, a clear improvement of the biofilm removal was observed when increasing the mean wall shear stress. The characterization of the foam and the interface phenomenons (using polarography, conductimetry, and bubble size analysis methods) indicated that mechanisms such as fluctuation in local wall shear stresses, or in the liquid film thickness between the bubbles and the steel wall induced by bubble passage, foam imbibition, and sweeping of the contamination within the liquid film could participate largely to the removal mechanisms. Finally, the life cycle assessment study demonstrated that foam flow cleaning could be a suitable technique to reduce water and energy consumption (7 and 8 times less, respectively) presenting less environmental impacts than CIP processes, with about 70%. Lastly, foam flow cleaning can be an alternative method, which can improve efficiency and reduce environmental impact. Additional activities conducted during the PhD period related to hygienic design are presented highlighting the role of the contaminants (spores and biofilms), the material (other than stainless steel) and the geometry (ducts or more complex design) in hygiene monitoring."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["13427667"]},{"key":"dc:format.filetype","label":"Dc Format Filetype","values":["PDF"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["PDF"]},{"key":"dc:title","label":"Title","values":["Numerical and experimental investigations of the rheological behavior of foam flow : application to the cleaning of surfaces contaminated by microorganisms in the food industries","Investigations numériques et expérimentales du comportement rhéologique de mousses en écoulement : application au nettoyage des surfaces contaminées par des micro-organismes dans les industries agro-alimentaires"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Investigations numériques et expérimentales du comportement rhéologique de mousses en écoulement : application au nettoyage des surfaces contaminées par des micro-organismes dans les industries agro-alimentaires"]},{"key":"tef:authorizedname","label":"Tef Authorizedname","values":["Bénézech, Thierry","École doctorale Sciences de la matière, du rayonnement et de l'environnement (Villeneuve d'Ascq, Nord)","Aloui, Fethi","Unité matériaux et transformations (UMET)","Faille, Christine","Legrand, Jack","Sampers, Imca","Duchesne, Alexis","Timmerman, Hein","Fameau, Anne-Laure","Whitehead, Kathryn","Saint-Jalmes, Arnaud"]},{"key":"tef:externalresource.creator","label":"Tef Externalresource Creator","values":["Heni Dallagi","Ramla Gheith","Ahmad Al Saabi","Christine Faille","Wolfgang Augustin","Thierry Benezech","Fethi Aloui","Laurent Bouvier","Laurent Wauquier","Fehti Aloui","Gaétan Rauwel","Thierry Bénézech","Maureen Deleplace","Thomas Dubois","Cosmin GRUESCU","Piyush KumarJha","Elodie Richard","Charles Cunault","Piyush Kumar Jha","Anna Ipatova"]},{"key":"tef:externalresource.date","label":"Tef Externalresource Date","values":["2018","2019","2022","2021","2020"]},{"key":"tef:externalresource.language","label":"Tef Externalresource Language","values":["en"]},{"key":"tef:externalresource.publisher","label":"Tef Externalresource Publisher","values":["ASME","Elsevier","iscience"]},{"key":"tef:externalresource.title","label":"Tef Externalresource Title","values":["CFD Characterization of a Wet Foam Flow Rheological Behavio","CFD Simulations of the Rheological Behavior of Aqueous Foam Flow Through a Half-Sudden Expansion","Numerical and experimental investigations into the rheological behaviour of wet foam flowing under a fence","Removal of Bacillus spores from stainless steel pipes by flow foam: Effect of the foam quality and velocity","Wet foam flow: A suitable method for improving surface hygiene in the food industry","Is foam flow cleaning effective and environmentally friendly in controlling the hygiene of surfaces contaminated with biofilms?","Does the vertical vs horizontal positioning of surfaces affect either biofilm formation on different materials or their resistance to detachment?","Influence of the design of fresh-cut food washing tanks on the growth kinetics of Pseudomonas fluorescens biofilms","Formation and resistance to cleaning of biofilms at air-liquid-wall interface. Influence of bacterial strain and material","Structure of deposits formed by drying of droplets contaminated with Bacillus spores determines their resistance to rinsing and cleaning"]},{"key":"tef:externalresource.type","label":"Tef Externalresource Type","values":["Text"]},{"key":"tef:internalref","label":"Tef Internalref","values":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_DIRECTEUR_DE_THESE_2","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2","MADS_DIRECTEUR_DE_THESE_3","MADS_MEMBRE_DU_JURY_3","MADS_MEMBRE_DU_JURY_4"]},{"key":"tef:oaisetspec","label":"Tef Oaisetspec","values":["ddc:660"]},{"key":"tef:record.agent","label":"Tef Record Agent","values":["ABES"]},{"key":"tef:record.agentnote","label":"Tef Record Agentnote","values":["Note"]},{"key":"tef:record.created","label":"Tef Record Created","values":["2022-03-14T10:06:12"]},{"key":"tef:record.modified","label":"Tef Record Modified","values":["2025-01-14T03:11:28Z"]},{"key":"tef:record.status","label":"Tef Record Status","values":["valide"]}]}],"canonical_facts":{"dc:contributor":["Université de Lille (2022-....)","Bénézech, Thierry","Aloui, Fethi","Faille, Christine"],"dc:contributor.advisor":["Bénézech, Thierry","Aloui, Fethi","Faille, Christine"],"dc:contributor.committeechair":["Legrand, Jack"],"dc:contributor.committeemember":["Sampers, Imca","Duchesne, Alexis","Timmerman, Hein","Fameau, Anne-Laure"],"dc:contributor.examiner":["Whitehead, Kathryn","Saint-Jalmes, Arnaud"],"dc:contributor.researchpartner":["Unité Matériaux et Transformations (Lille ; 2010-....)"],"dc:contributor.researchpartner.identifier":["1002334","https://www.idref.fr/161609465"],"dc:creator":["Dallagi, Heni"],"dc:date":["2022-02-28"],"dc:date.dateaccepted":["2022-02-28"],"dc:description":["La caractérisation expérimentale et numérique du comportement rhéologique d'une mousse aqueuse s'écoulant à l'intérieur d'un tuyau horizontal avec et sans singularités (demi-expansion soudaine, et chicane) a été étudiée. Différentes conditions d'écoulement ont été étudiées en faisant varier les qualités de mousse (55-85%), et trois nombres de Reynolds (32, 65, et 97). Les mesures de la pression, de la répartition de la vitesse locale et de la contrariante et de l'épaisseur des films liquides au niveau de la paroi à l'aide respectivement de capteurs de pression, de la PIV, de la polarographie et de la conductimétrie ont montré une réorganisation de la mousse en aval du changement de géométrie, avec un film liquide plus épais au fond du conduit, des bulles de plus grande taille au sommet, ainsi qu'une plus grande fraction de vide de la mousse augmentant de la partie inférieure à la partie supérieure de la section du conduit. En outre, la mousse présenterait un caractère visco-élastique comparable à celui d'un liquide monophasique non newtonien. Des simulations de dynamique des fluides ont été entreprises pour prédire ce comportement rhéologique de la mousse, les deux modèles Herschel-Bulkley et Bingham ont été testés en tenant compte de la présence d'un film liquide sous-jacent au fond du canal. La comparaison entre les résultats expérimentaux et numériques a montré que, quelle que soit la qualité de la mousse, le modèle de Herschel-Bulkley pouvait décrire avec précision le comportement rhéologique de la mousse dans les différentes conditions d'écoulement analysées.Le deuxième objectif était d'étudier la capacité d'un écoulement de mousse humide (qualité de 50%) à nettoyer des surfaces en acier inoxydable contaminées par des micro-organismes. Pour cela, deux types de contamination ont été étudiés, des gouttelettes contenant des spores de Bacillus subtilis (soit hydrophiles Bs PY79 ou hydrophobes Bs PY79 spsA), et des biofilms produits par trois souches de bactéries (Escherichia coli SS2, Bacillus cereus 98/4, et Pseudomonas fluorescens Pf1). Différentes conditions d'écoulement ont été réalisées en faisant varier les contraintes de cisaillement pariétale (2.2 - 13.2 Pa), et la taille des bulles (0.18-0.34 mm) dans un conduit sans changement géométrique, afin d'identifier les mécanismes de libération de la contamination et ainsi mieux contrôler et optimiser le processus de nettoyage. Les résultats montrent que, par rapport au NEP conventionnel, le flux de mousse a éliminé efficacement les spores ainsi que les biofilms. De plus, la combinaison d'une contrainte de cisaillement pariétale élevée et de bulles de petite taille (<0,2 mm) s'est avérée prometteuse pour améliorer l'efficacité du nettoyage des spores. D'autre part, une nette amélioration de l'élimination des biofilms a été observée en augmentant la contrainte de cisaillement pariétale. La caractérisation de la mousse et des phénomènes d'interface a indiqué que des mécanismes tels que la fluctuation des contraintes de cisaillement locales, ou de l'épaisseur du film liquide entre les bulles et la paroi induite par le passage des bulles, l'imbibition de la mousse et le balayage de la contamination dans le film liquide, pourraient participer largement aux mécanismes d'élimination. Enfin, l'étude d'analyse du cycle de vie a démontré que le nettoyage à la mousse peut être une technique appropriée pour réduire la consommation d'eau et d'énergie (7 et 8 fois moins) présentant moins d'impacts environnementaux que les procédés CIP, avec environ 70%. Enfin, le nettoyage à la mousse peut être une méthode alternative, qui peut améliorer l'efficacité et réduire l'impact environnemental.D'autres activités menées au cours de la période de doctorat liées à la conception hygiénique sont présentées en soulignant le rôle des contaminants (spores et biofilms), du matériau (autre que l'acier inoxydable) et de la géométrie (conduits ou conception plus complexe) dans le contrôle de l'hygiène.","In this research, experimental and numerical characterization of the rheological behavior of an aqueous foam flowing inside a horizontal pipe with and without singularities (presence of half-sudden expansion, and a fence) were investigated. Different conditions of foam flow were studied by varying the foam qualities (from 55% to 85%), and three Reynolds numbers (32, 65, and 97). Measurements of the pressure measurements, and at the wall the local velocity repartition and the thickness of the liquid films using respectively pressure sensors, Particle Image Velocimetry, and a conductimetry technique shown a reorganization of the foam downstream the geometry change, with a thicker liquid film at the duct bottom, larger bubble sizes at the top, as well as a larger foam void fraction increased from the bottom to the top part of the duct section. In addition, foam would present a visco-elastic character comparable to a non-Newtonian monophasic liquid. Computational Fluid Dynamics simulations were undertaken to predict this rheological behavior of the foam, the two models Herschel-Bulkley and Bingham were tested taken into account the presence of an underlying liquid film at the bottom of the channel . Comparison between experimental and numerical results showed that regardless of the foam quality, Herschel-Bulkley model could accurately describe the rheological behaviour of the aqueous foam under the different flow conditions analysed.The second target was to investigate the ability of a wet foam flow (quality of 50%) to clean stainless-steel surfaces contaminated by microorganisms. For this purpose, two different contamination patterns were studied, droplets containing Bacillus subtilis spores (either hydrophilic Bs PY79 or hydrophobic Bs PY79 spsA), and biofilms produced by three bacteria strains encountered in food industry production plants (Escherichia coli SS2, Bacillus cereus 98/4, and Pseudomonas fluorescens Pf1). Different flow conditions were performed by varying the wall shear stresses (2.2 - 13.2 Pa), and bubble sizes (0.18-0.34 mm) in a straight duct with no geometrical changes, in order to identify the mechanisms of contamination release and thus better control and optimize the foam cleaning process. Results show that compared to conventional cleaning-in-place, foam flow effectively removed Bs spores as well as Bc-98/4, Ec-SS2, and Pf1 biofilms. Moreover, the combination of high shear stress at the wall and small bubble sizes (<0.2 mm) showed promise for improving the cleaning efficiency of spores. On the other hand, a clear improvement of the biofilm removal was observed when increasing the mean wall shear stress. The characterization of the foam and the interface phenomenons (using polarography, conductimetry, and bubble size analysis methods) indicated that mechanisms such as fluctuation in local wall shear stresses, or in the liquid film thickness between the bubbles and the steel wall induced by bubble passage, foam imbibition, and sweeping of the contamination within the liquid film could participate largely to the removal mechanisms. Finally, the life cycle assessment study demonstrated that foam flow cleaning could be a suitable technique to reduce water and energy consumption (7 and 8 times less, respectively) presenting less environmental impacts than CIP processes, with about 70%. Lastly, foam flow cleaning can be an alternative method, which can improve efficiency and reduce environmental impact. Additional activities conducted during the PhD period related to hygienic design are presented highlighting the role of the contaminants (spores and biofilms), the material (other than stainless steel) and the geometry (ducts or more complex design) in hygiene monitoring."],"dc:description.abstract":["La caractérisation expérimentale et numérique du comportement rhéologique d'une mousse aqueuse s'écoulant à l'intérieur d'un tuyau horizontal avec et sans singularités (demi-expansion soudaine, et chicane) a été étudiée. Différentes conditions d'écoulement ont été étudiées en faisant varier les qualités de mousse (55-85%), et trois nombres de Reynolds (32, 65, et 97). Les mesures de la pression, de la répartition de la vitesse locale et de la contrariante et de l'épaisseur des films liquides au niveau de la paroi à l'aide respectivement de capteurs de pression, de la PIV, de la polarographie et de la conductimétrie ont montré une réorganisation de la mousse en aval du changement de géométrie, avec un film liquide plus épais au fond du conduit, des bulles de plus grande taille au sommet, ainsi qu'une plus grande fraction de vide de la mousse augmentant de la partie inférieure à la partie supérieure de la section du conduit. En outre, la mousse présenterait un caractère visco-élastique comparable à celui d'un liquide monophasique non newtonien. Des simulations de dynamique des fluides ont été entreprises pour prédire ce comportement rhéologique de la mousse, les deux modèles Herschel-Bulkley et Bingham ont été testés en tenant compte de la présence d'un film liquide sous-jacent au fond du canal. La comparaison entre les résultats expérimentaux et numériques a montré que, quelle que soit la qualité de la mousse, le modèle de Herschel-Bulkley pouvait décrire avec précision le comportement rhéologique de la mousse dans les différentes conditions d'écoulement analysées.Le deuxième objectif était d'étudier la capacité d'un écoulement de mousse humide (qualité de 50%) à nettoyer des surfaces en acier inoxydable contaminées par des micro-organismes. Pour cela, deux types de contamination ont été étudiés, des gouttelettes contenant des spores de Bacillus subtilis (soit hydrophiles Bs PY79 ou hydrophobes Bs PY79 spsA), et des biofilms produits par trois souches de bactéries (Escherichia coli SS2, Bacillus cereus 98/4, et Pseudomonas fluorescens Pf1). Différentes conditions d'écoulement ont été réalisées en faisant varier les contraintes de cisaillement pariétale (2.2 - 13.2 Pa), et la taille des bulles (0.18-0.34 mm) dans un conduit sans changement géométrique, afin d'identifier les mécanismes de libération de la contamination et ainsi mieux contrôler et optimiser le processus de nettoyage. Les résultats montrent que, par rapport au NEP conventionnel, le flux de mousse a éliminé efficacement les spores ainsi que les biofilms. De plus, la combinaison d'une contrainte de cisaillement pariétale élevée et de bulles de petite taille (<0,2 mm) s'est avérée prometteuse pour améliorer l'efficacité du nettoyage des spores. D'autre part, une nette amélioration de l'élimination des biofilms a été observée en augmentant la contrainte de cisaillement pariétale. La caractérisation de la mousse et des phénomènes d'interface a indiqué que des mécanismes tels que la fluctuation des contraintes de cisaillement locales, ou de l'épaisseur du film liquide entre les bulles et la paroi induite par le passage des bulles, l'imbibition de la mousse et le balayage de la contamination dans le film liquide, pourraient participer largement aux mécanismes d'élimination. Enfin, l'étude d'analyse du cycle de vie a démontré que le nettoyage à la mousse peut être une technique appropriée pour réduire la consommation d'eau et d'énergie (7 et 8 fois moins) présentant moins d'impacts environnementaux que les procédés CIP, avec environ 70%. Enfin, le nettoyage à la mousse peut être une méthode alternative, qui peut améliorer l'efficacité et réduire l'impact environnemental.D'autres activités menées au cours de la période de doctorat liées à la conception hygiénique sont présentées en soulignant le rôle des contaminants (spores et biofilms), du matériau (autre que l'acier inoxydable) et de la géométrie (conduits ou conception plus complexe) dans le contrôle de l'hygiène.","In this research, experimental and numerical characterization of the rheological behavior of an aqueous foam flowing inside a horizontal pipe with and without singularities (presence of half-sudden expansion, and a fence) were investigated. Different conditions of foam flow were studied by varying the foam qualities (from 55% to 85%), and three Reynolds numbers (32, 65, and 97). Measurements of the pressure measurements, and at the wall the local velocity repartition and the thickness of the liquid films using respectively pressure sensors, Particle Image Velocimetry, and a conductimetry technique shown a reorganization of the foam downstream the geometry change, with a thicker liquid film at the duct bottom, larger bubble sizes at the top, as well as a larger foam void fraction increased from the bottom to the top part of the duct section. In addition, foam would present a visco-elastic character comparable to a non-Newtonian monophasic liquid. Computational Fluid Dynamics simulations were undertaken to predict this rheological behavior of the foam, the two models Herschel-Bulkley and Bingham were tested taken into account the presence of an underlying liquid film at the bottom of the channel . Comparison between experimental and numerical results showed that regardless of the foam quality, Herschel-Bulkley model could accurately describe the rheological behaviour of the aqueous foam under the different flow conditions analysed.The second target was to investigate the ability of a wet foam flow (quality of 50%) to clean stainless-steel surfaces contaminated by microorganisms. For this purpose, two different contamination patterns were studied, droplets containing Bacillus subtilis spores (either hydrophilic Bs PY79 or hydrophobic Bs PY79 spsA), and biofilms produced by three bacteria strains encountered in food industry production plants (Escherichia coli SS2, Bacillus cereus 98/4, and Pseudomonas fluorescens Pf1). Different flow conditions were performed by varying the wall shear stresses (2.2 - 13.2 Pa), and bubble sizes (0.18-0.34 mm) in a straight duct with no geometrical changes, in order to identify the mechanisms of contamination release and thus better control and optimize the foam cleaning process. Results show that compared to conventional cleaning-in-place, foam flow effectively removed Bs spores as well as Bc-98/4, Ec-SS2, and Pf1 biofilms. Moreover, the combination of high shear stress at the wall and small bubble sizes (<0.2 mm) showed promise for improving the cleaning efficiency of spores. On the other hand, a clear improvement of the biofilm removal was observed when increasing the mean wall shear stress. The characterization of the foam and the interface phenomenons (using polarography, conductimetry, and bubble size analysis methods) indicated that mechanisms such as fluctuation in local wall shear stresses, or in the liquid film thickness between the bubbles and the steel wall induced by bubble passage, foam imbibition, and sweeping of the contamination within the liquid film could participate largely to the removal mechanisms. Finally, the life cycle assessment study demonstrated that foam flow cleaning could be a suitable technique to reduce water and energy consumption (7 and 8 times less, respectively) presenting less environmental impacts than CIP processes, with about 70%. Lastly, foam flow cleaning can be an alternative method, which can improve efficiency and reduce environmental impact. Additional activities conducted during the PhD period related to hygienic design are presented highlighting the role of the contaminants (spores and biofilms), the material (other than stainless steel) and the geometry (ducts or more complex design) in hygiene monitoring."],"dc:format.extent":["13427667"],"dc:format.filetype":["PDF"],"dc:format.medium":["PDF"],"dc:identifier":["http://www.theses.fr/2022ULILR003/document"],"dc:identifier.doi":["https://doi.org/10.70675/2e91c3efzb4e4z4e65z8ea2z38f0495e1fb6"],"dc:identifier.fulltext":["ULIL/THESE_180054/document/0/0/These_DALLAGI_Heni.pdf"],"dc:identifier.uri":["https://theses.fr/2022ULILR003","https://theses.hal.science/tel-03921788","https://theses.fr/2022ULILR003/abes"],"dc:language":["en"],"dc:language.rfc3066":["en"],"dc:rights":["Open Access","http://purl.org/eprint/accessRights/OpenAccess"],"dc:rights.permissions":["display, duplicate, print"],"dc:subject":["Nettoyage à la mousse","Foam flow","Rheological behavior","Cleaning-In-Place","CFD","Spores and Biofilms","LCA"],"dc:subject.rameau":["Mousse (chimie) -- Propriétés mécaniques","Rhéologie -- Modèles mathématiques","Surfaces (technologie) -- Nettoyage","Biofilms","Spores bactériennes","Modélisation CFD","Analyse du cycle de vie"],"dc:subject.uri":["https://www.idref.fr/031747337","https://www.idref.fr/029208971","https://www.idref.fr/027536394","https://www.idref.fr/027551385","https://www.idref.fr/027355357","https://www.idref.fr/027579999","https://www.idref.fr/031449352","https://www.idref.fr/031380697","https://www.idref.fr/190664126","https://www.idref.fr/16162457X"],"dc:title":["Numerical and experimental investigations of the rheological behavior of foam flow : application to the cleaning of surfaces contaminated by microorganisms in the food industries","Investigations numériques et expérimentales du comportement rhéologique de mousses en écoulement : application au nettoyage des surfaces contaminées par des micro-organismes dans les industries agro-alimentaires"],"dc:title.alternative":["Investigations numériques et expérimentales du comportement rhéologique de mousses en écoulement : application au nettoyage des surfaces contaminées par des micro-organismes dans les industries agro-alimentaires"],"dc:type":["Electronic Thesis or Dissertation","Text"],"dc:type.dcmitype":["Text"],"person:birthdate":["1993-09-13"],"person:identifier.idref":["https://www.idref.fr/262791560","https://www.idref.fr/059743131","https://www.idref.fr/060386576","https://www.idref.fr/259909572","https://www.idref.fr/150517955","https://www.idref.fr/188103767","https://www.idref.fr/158357744","https://www.idref.fr/033724415"],"person:name.birth":["Dallagi"],"person:nationality":["FR"],"tef:authorizedname":["Bénézech, Thierry","École doctorale Sciences de la matière, du rayonnement et de l'environnement (Villeneuve d'Ascq, Nord)","Aloui, Fethi","Unité matériaux et transformations (UMET)","Faille, Christine","Legrand, Jack","Sampers, Imca","Duchesne, Alexis","Timmerman, Hein","Fameau, Anne-Laure","Whitehead, Kathryn","Saint-Jalmes, Arnaud"],"tef:externalresource.creator":["Heni Dallagi","Ramla Gheith","Ahmad Al Saabi","Christine Faille","Wolfgang Augustin","Thierry Benezech","Fethi Aloui","Laurent Bouvier","Laurent Wauquier","Fehti Aloui","Gaétan Rauwel","Thierry Bénézech","Maureen Deleplace","Thomas Dubois","Cosmin GRUESCU","Piyush KumarJha","Elodie Richard","Charles Cunault","Piyush Kumar Jha","Anna Ipatova"],"tef:externalresource.date":["2018","2019","2022","2021","2020"],"tef:externalresource.language":["en"],"tef:externalresource.publisher":["ASME","Elsevier","iscience"],"tef:externalresource.title":["CFD Characterization of a Wet Foam Flow Rheological Behavio","CFD Simulations of the Rheological Behavior of Aqueous Foam Flow Through a Half-Sudden Expansion","Numerical and experimental investigations into the rheological behaviour of wet foam flowing under a fence","Removal of Bacillus spores from stainless steel pipes by flow foam: Effect of the foam quality and velocity","Wet foam flow: A suitable method for improving surface hygiene in the food industry","Is foam flow cleaning effective and environmentally friendly in controlling the hygiene of surfaces contaminated with biofilms?","Does the vertical vs horizontal positioning of surfaces affect either biofilm formation on different materials or their resistance to detachment?","Influence of the design of fresh-cut food washing tanks on the growth kinetics of Pseudomonas fluorescens biofilms","Formation and resistance to cleaning of biofilms at air-liquid-wall interface. Influence of bacterial strain and material","Structure of deposits formed by drying of droplets contaminated with Bacillus spores determines their resistance to rinsing and cleaning"],"tef:externalresource.type":["Text"],"tef:internalref":["MADS_DIRECTEUR_DE_THESE_1","MADS_PRESIDENT_DU_JURY","MADS_MEMBRE_DU_JURY_1","MADS_RAPPORTEUR_1","MADS_ECOLE_DOCTORALE_1","MADS_PARTENAIRE_DE_RECHERCHE_1","MADS_DIRECTEUR_DE_THESE_2","MADS_MEMBRE_DU_JURY_2","MADS_RAPPORTEUR_2","MADS_DIRECTEUR_DE_THESE_3","MADS_MEMBRE_DU_JURY_3","MADS_MEMBRE_DU_JURY_4"],"tef:oaisetspec":["ddc:660"],"tef:record.agent":["ABES"],"tef:record.agentnote":["Note"],"tef:record.created":["2022-03-14T10:06:12"],"tef:record.modified":["2025-01-14T03:11:28Z"],"tef:record.status":["valide"],"thesis:by_published_works":["oui"],"thesis:degree_discipline":["Biotechnologies agroalimentaires, sciences de l'aliment, physiologie"],"thesis:degree_level":["Doctorat"],"thesis:degree_name":["Docteur es"],"thesis:doctoral_school":["École doctorale Sciences de la matière, du rayonnement et de l'environnement (Lille ; 1992-....)"],"thesis:doctoral_school_identifier":["https://www.idref.fr/148937330"],"thesis:institution_identifier":["https://www.idref.fr/259265152"],"thesis:institution_name":["Université de Lille (2022-....)"],"thesis:jury_release_opinion":["oui"],"thesis:thesis_identifier":["2022ULILR003"]},"updated_at":"2026-11-27T10:06:29Z"}