{"id":{"repo_id":"strathclyde","oai_identifier":"oai:strathclyde:4b29b6121"},"canonical_url":"https://search.ndltd.org/etd/strathclyde/oai:strathclyde:4b29b6121","repository":{"repo_id":"strathclyde","name":"University of Strathclyde","base_url":"https://stax.strath.ac.uk/catalog/oai"},"display":{"title":"High-voltage pulse generators incorporating modular multilevel converter sub-modules","abstract":"Recent research established the effectiveness of applying a pulsed electric field to deactivate harmful microorganisms (such as bacteria and E. coli). Successful deactivation is achieved by lethal electroporation; a process that produces electric pores in the biological cell membrane of the harmful microorganisms when subjected to high-voltage (HV) pulses. The HV pulses are designed to create pores beyond a critical size at which the biological cell can reseal.;In contrast when applying non-lethal electroporation, the cell-membrane survives after the electroporation process. This is required, for example, when inserting protein cells in the cell-membrane. In both lethal and non-lethal electroporation, HV pulses in the kilo-Volt range (1-100 kV) with durations ranging between nanoseconds and milliseconds are required.;This thesis proposes nine pulse generator (PG) topologies based on power electronic devices and modular multilevel converter sub-modules. The proposed topologies are divided into two main groups namely: PGs fed from a HV DC supply and PGs fed from an LV DC supply. The first group presents a new family of HV DC fed topologies that improve the performance of existing HV DC fed PGs, such as flexible pulse-waveform generation and full utilisation of the DC link voltage.;The second group is dedicated to a new family of LV DC fed PG topologies which have flexible pulse-waveform generation, controlled operation efficiency, and high voltage gain.;All the proposed PG topologies share the important aspect in the newly developed HV PGs, that is modularity, which offers redundancy and robust pulse generation operation.;The presented PG topologies are supported by theoretical analysis, simulations, and experimentation.","abstract_html":"Recent research established the effectiveness of applying a pulsed electric field to deactivate harmful microorganisms (such as bacteria and E. coli). Successful deactivation is achieved by lethal electroporation; a process that produces electric pores in the biological cell membrane of the harmful microorganisms when subjected to high-voltage (HV) pulses. The HV pulses are designed to create pores beyond a critical size at which the biological cell can reseal.;In contrast when applying non-lethal electroporation, the cell-membrane survives after the electroporation process. This is required, for example, when inserting protein cells in the cell-membrane. In both lethal and non-lethal electroporation, HV pulses in the kilo-Volt range (1-100 kV) with durations ranging between nanoseconds and milliseconds are required.;This thesis proposes nine pulse generator (PG) topologies based on power electronic devices and modular multilevel converter sub-modules. The proposed topologies are divided into two main groups namely: PGs fed from a HV DC supply and PGs fed from an LV DC supply. The first group presents a new family of HV DC fed topologies that improve the performance of existing HV DC fed PGs, such as flexible pulse-waveform generation and full utilisation of the DC link voltage.;The second group is dedicated to a new family of LV DC fed PG topologies which have flexible pulse-waveform generation, controlled operation efficiency, and high voltage gain.;All the proposed PG topologies share the important aspect in the newly developed HV PGs, that is modularity, which offers redundancy and robust pulse generation operation.;The presented PG topologies are supported by theoretical analysis, simulations, and experimentation.","abstract_has_math":false,"creators":["Elgenedy, Mohamed Atef"],"institution":"University of Strathclyde","degree_name":"phd","degree_level":"doctoral-pg","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Holliday, Derrick","Williams, Barry"],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-21T19:54:56Z","subjects":[],"languages":[],"rights":[],"rights_urls":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/ds93-qb07"],"render_values":[{"text":"10.48730/ds93-qb07","href":"https://doi.org/10.48730/ds93-qb07","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["T14896"],"render_values":[{"text":"T14896","href":null,"code":true}]}],"person_identifier_entries":[{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["201552499"],"render_values":[{"text":"201552499","href":null,"code":true}]}]},"links":{"outbound_url":"https://stax.strath.ac.uk/concern/theses/4b29b6121","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stax.strath.ac.uk/concern/theses/4b29b6121","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stax.strath.ac.uk/catalog/oai?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Astrathclyde%3A4b29b6121","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Holliday, Derrick","Williams, Barry"]},{"key":"dc:creator","label":"Author","values":["Elgenedy, Mohamed Atef"]},{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["201552499"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:date.issued","label":"Date","values":["2018"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Electronic and Electrical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Strathclyde"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://stax.strath.ac.uk/downloads/xg94hp844"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral-pg"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]},{"key":"dc:type.uri","label":"Dc Type URI","values":["http://purl.org/coar/resource_type/c_db06"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://stax.strath.ac.uk/thesis_copyright_statement/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["T14896"]},{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/ds93-qb07"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/4b29b6121"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Recent research established the effectiveness of applying a pulsed electric field to deactivate harmful microorganisms (such as bacteria and E. coli). Successful deactivation is achieved by lethal electroporation; a process that produces electric pores in the biological cell membrane of the harmful microorganisms when subjected to high-voltage (HV) pulses. The HV pulses are designed to create pores beyond a critical size at which the biological cell can reseal.;In contrast when applying non-lethal electroporation, the cell-membrane survives after the electroporation process. This is required, for example, when inserting protein cells in the cell-membrane. In both lethal and non-lethal electroporation, HV pulses in the kilo-Volt range (1-100 kV) with durations ranging between nanoseconds and milliseconds are required.;This thesis proposes nine pulse generator (PG) topologies based on power electronic devices and modular multilevel converter sub-modules. The proposed topologies are divided into two main groups namely: PGs fed from a HV DC supply and PGs fed from an LV DC supply. The first group presents a new family of HV DC fed topologies that improve the performance of existing HV DC fed PGs, such as flexible pulse-waveform generation and full utilisation of the DC link voltage.;The second group is dedicated to a new family of LV DC fed PG topologies which have flexible pulse-waveform generation, controlled operation efficiency, and high voltage gain.;All the proposed PG topologies share the important aspect in the newly developed HV PGs, that is modularity, which offers redundancy and robust pulse generation operation.;The presented PG topologies are supported by theoretical analysis, simulations, and experimentation."]},{"key":"dc:description.abstract","label":"Abstract","values":["Recent research established the effectiveness of applying a pulsed electric field to deactivate harmful microorganisms (such as bacteria and E. coli). Successful deactivation is achieved by lethal electroporation; a process that produces electric pores in the biological cell membrane of the harmful microorganisms when subjected to high-voltage (HV) pulses. The HV pulses are designed to create pores beyond a critical size at which the biological cell can reseal.;In contrast when applying non-lethal electroporation, the cell-membrane survives after the electroporation process. This is required, for example, when inserting protein cells in the cell-membrane. In both lethal and non-lethal electroporation, HV pulses in the kilo-Volt range (1-100 kV) with durations ranging between nanoseconds and milliseconds are required.;This thesis proposes nine pulse generator (PG) topologies based on power electronic devices and modular multilevel converter sub-modules. The proposed topologies are divided into two main groups namely: PGs fed from a HV DC supply and PGs fed from an LV DC supply. The first group presents a new family of HV DC fed topologies that improve the performance of existing HV DC fed PGs, such as flexible pulse-waveform generation and full utilisation of the DC link voltage.;The second group is dedicated to a new family of LV DC fed PG topologies which have flexible pulse-waveform generation, controlled operation efficiency, and high voltage gain.;All the proposed PG topologies share the important aspect in the newly developed HV PGs, that is modularity, which offers redundancy and robust pulse generation operation.;The presented PG topologies are supported by theoretical analysis, simulations, and experimentation."]},{"key":"dc:title","label":"Title","values":["High-voltage pulse generators incorporating modular multilevel converter sub-modules"]}]}],"canonical_facts":{"dc:contributor.advisor":["Holliday, Derrick","Williams, Barry"],"dc:creator":["Elgenedy, Mohamed Atef"],"dc:creator.authoridentifier":["201552499"],"dc:date":["2018"],"dc:date.issued":["2018"],"dc:description":["Recent research established the effectiveness of applying a pulsed electric field to deactivate harmful microorganisms (such as bacteria and E. coli). Successful deactivation is achieved by lethal electroporation; a process that produces electric pores in the biological cell membrane of the harmful microorganisms when subjected to high-voltage (HV) pulses. The HV pulses are designed to create pores beyond a critical size at which the biological cell can reseal.;In contrast when applying non-lethal electroporation, the cell-membrane survives after the electroporation process. This is required, for example, when inserting protein cells in the cell-membrane. In both lethal and non-lethal electroporation, HV pulses in the kilo-Volt range (1-100 kV) with durations ranging between nanoseconds and milliseconds are required.;This thesis proposes nine pulse generator (PG) topologies based on power electronic devices and modular multilevel converter sub-modules. The proposed topologies are divided into two main groups namely: PGs fed from a HV DC supply and PGs fed from an LV DC supply. The first group presents a new family of HV DC fed topologies that improve the performance of existing HV DC fed PGs, such as flexible pulse-waveform generation and full utilisation of the DC link voltage.;The second group is dedicated to a new family of LV DC fed PG topologies which have flexible pulse-waveform generation, controlled operation efficiency, and high voltage gain.;All the proposed PG topologies share the important aspect in the newly developed HV PGs, that is modularity, which offers redundancy and robust pulse generation operation.;The presented PG topologies are supported by theoretical analysis, simulations, and experimentation."],"dc:description.abstract":["Recent research established the effectiveness of applying a pulsed electric field to deactivate harmful microorganisms (such as bacteria and E. coli). Successful deactivation is achieved by lethal electroporation; a process that produces electric pores in the biological cell membrane of the harmful microorganisms when subjected to high-voltage (HV) pulses. The HV pulses are designed to create pores beyond a critical size at which the biological cell can reseal.;In contrast when applying non-lethal electroporation, the cell-membrane survives after the electroporation process. This is required, for example, when inserting protein cells in the cell-membrane. In both lethal and non-lethal electroporation, HV pulses in the kilo-Volt range (1-100 kV) with durations ranging between nanoseconds and milliseconds are required.;This thesis proposes nine pulse generator (PG) topologies based on power electronic devices and modular multilevel converter sub-modules. The proposed topologies are divided into two main groups namely: PGs fed from a HV DC supply and PGs fed from an LV DC supply. The first group presents a new family of HV DC fed topologies that improve the performance of existing HV DC fed PGs, such as flexible pulse-waveform generation and full utilisation of the DC link voltage.;The second group is dedicated to a new family of LV DC fed PG topologies which have flexible pulse-waveform generation, controlled operation efficiency, and high voltage gain.;All the proposed PG topologies share the important aspect in the newly developed HV PGs, that is modularity, which offers redundancy and robust pulse generation operation.;The presented PG topologies are supported by theoretical analysis, simulations, and experimentation."],"dc:identifier":["T14896"],"dc:identifier.doi":["10.48730/ds93-qb07"],"dc:identifier.uri":["https://stax.strath.ac.uk/concern/theses/4b29b6121"],"dc:publisher.department":["Department of Electronic and Electrical Engineering"],"dc:publisher.institution":["University of Strathclyde"],"dc:relation.uri":["https://stax.strath.ac.uk/downloads/xg94hp844"],"dc:rights.uri":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"dc:title":["High-voltage pulse generators incorporating modular multilevel converter sub-modules"],"dc:type.qualificationlevel":["doctoral-pg"],"dc:type.qualificationname":["phd"],"dc:type.uri":["http://purl.org/coar/resource_type/c_db06"]},"updated_at":"2026-11-21T19:54:56Z"}