{"id":{"repo_id":"strathclyde","oai_identifier":"oai:strathclyde:cj82k7327"},"canonical_url":"https://search.ndltd.org/etd/strathclyde/oai:strathclyde:cj82k7327","repository":{"repo_id":"strathclyde","name":"University of Strathclyde","base_url":"https://stax.strath.ac.uk/catalog/oai"},"display":{"title":"Mapping totally-focused flaw signal variation introduced by interface curvature in ultrasonic array inspection","abstract":"This thesis documents the use of the Total Focusing Method (TFM) for performing ultrasonic C-scans of components with irregular and curved surfaces. Ultrasonic inspection depends on an understanding of the link between an ultrasonic indication and flaw size. Some existing methods at Rolls-Royce use target defects of a known size and metal path through flat surfaces to create a Distance Amplitude Curve (DAC) that can be used to accurately size flaws. This study investigated a DAC equivalent for surface-adaptive TFM techniques applied through non-planar surfaces. There was business interest in development of this technique, and also in its delivery by use of general purpose robotic manipulators. Firstly, a robotic inspection process was developed, and a C-scan was conducted on an irregular titanium plate. cueART, software developed by the University of Strathclyde was adapted to create a TFM C-scan. Results were found to be comparable to an existing production inspection process. A series of curved test pieces were manufactured and target Flat-Bottomed Hole (FBH) defects were added. BRAIN, software developed by Bristol university, was adapted and used with equipment at Rolls-Royce to conduct TFM C-scans. DAC curves were generated experimentally for a test inspection, showing convex radii from 10 to 40 mm led to a drop of 2 dB, and concave 10 dB. This was repeated at various depths to produce multiple DAC curves. Modelling techniques for these experimental cases were developed, finding that a 2D finite element model, and 3D CIVA model followed a similar trend to the DAC. Modelling was used to extend results to produce a map of peak flaw signal through a curved surface. An experimental study of flat, rough surfaces showed that an Ra of 12 ?m led to a 6.4 dB reduction in peak TFM signal, and13.2 dB reduction in signal to noise ratio.","abstract_html":"This thesis documents the use of the Total Focusing Method (TFM) for performing ultrasonic C-scans of components with irregular and curved surfaces. Ultrasonic inspection depends on an understanding of the link between an ultrasonic indication and flaw size. Some existing methods at Rolls-Royce use target defects of a known size and metal path through flat surfaces to create a Distance Amplitude Curve (DAC) that can be used to accurately size flaws. This study investigated a DAC equivalent for surface-adaptive TFM techniques applied through non-planar surfaces. There was business interest in development of this technique, and also in its delivery by use of general purpose robotic manipulators. Firstly, a robotic inspection process was developed, and a C-scan was conducted on an irregular titanium plate. cueART, software developed by the University of Strathclyde was adapted to create a TFM C-scan. Results were found to be comparable to an existing production inspection process. A series of curved test pieces were manufactured and target Flat-Bottomed Hole (FBH) defects were added. BRAIN, software developed by Bristol university, was adapted and used with equipment at Rolls-Royce to conduct TFM C-scans. DAC curves were generated experimentally for a test inspection, showing convex radii from 10 to 40 mm led to a drop of 2 dB, and concave 10 dB. This was repeated at various depths to produce multiple DAC curves. Modelling techniques for these experimental cases were developed, finding that a 2D finite element model, and 3D CIVA model followed a similar trend to the DAC. Modelling was used to extend results to produce a map of peak flaw signal through a curved surface. An experimental study of flat, rough surfaces showed that an Ra of 12 ?m led to a 6.4 dB reduction in peak TFM signal, and13.2 dB reduction in signal to noise ratio.","abstract_has_math":false,"creators":["Brown, Roy"],"institution":"University of Strathclyde","degree_name":"engd","degree_level":"doctoral-pg","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Pierce, Gareth"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-19T13:55:43Z","subjects":[],"languages":[],"rights":[],"rights_urls":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/am4h-hk33"],"render_values":[{"text":"10.48730/am4h-hk33","href":"https://doi.org/10.48730/am4h-hk33","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["T15479"],"render_values":[{"text":"T15479","href":null,"code":true}]}],"person_identifier_entries":[{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["201385909"],"render_values":[{"text":"201385909","href":null,"code":true}]}]},"links":{"outbound_url":"https://stax.strath.ac.uk/concern/theses/cj82k7327","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stax.strath.ac.uk/concern/theses/cj82k7327","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stax.strath.ac.uk/catalog/oai?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Astrathclyde%3Acj82k7327","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pierce, Gareth"]},{"key":"dc:creator","label":"Author","values":["Brown, Roy"]},{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["201385909"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Electronic and Electrical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Strathclyde"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://stax.strath.ac.uk/downloads/jw827c105"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral-pg"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["engd"]},{"key":"dc:type.uri","label":"Dc Type URI","values":["http://purl.org/coar/resource_type/c_db06"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://stax.strath.ac.uk/thesis_copyright_statement/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["T15479"]},{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/am4h-hk33"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/cj82k7327"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["\"Engineering Doctorate in Non-Destructive Evaluation\" -- title page.","This thesis documents the use of the Total Focusing Method (TFM) for performing ultrasonic C-scans of components with irregular and curved surfaces. Ultrasonic inspection depends on an understanding of the link between an ultrasonic indication and flaw size. Some existing methods at Rolls-Royce use target defects of a known size and metal path through flat surfaces to create a Distance Amplitude Curve (DAC) that can be used to accurately size flaws. This study investigated a DAC equivalent for surface-adaptive TFM techniques applied through non-planar surfaces. There was business interest in development of this technique, and also in its delivery by use of general purpose robotic manipulators. Firstly, a robotic inspection process was developed, and a C-scan was conducted on an irregular titanium plate. cueART, software developed by the University of Strathclyde was adapted to create a TFM C-scan. Results were found to be comparable to an existing production inspection process. A series of curved test pieces were manufactured and target Flat-Bottomed Hole (FBH) defects were added. BRAIN, software developed by Bristol university, was adapted and used with equipment at Rolls-Royce to conduct TFM C-scans. DAC curves were generated experimentally for a test inspection, showing convex radii from 10 to 40 mm led to a drop of 2 dB, and concave 10 dB. This was repeated at various depths to produce multiple DAC curves. Modelling techniques for these experimental cases were developed, finding that a 2D finite element model, and 3D CIVA model followed a similar trend to the DAC. Modelling was used to extend results to produce a map of peak flaw signal through a curved surface. An experimental study of flat, rough surfaces showed that an Ra of 12 ?m led to a 6.4 dB reduction in peak TFM signal, and13.2 dB reduction in signal to noise ratio."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis documents the use of the Total Focusing Method (TFM) for performing ultrasonic C-scans of components with irregular and curved surfaces. Ultrasonic inspection depends on an understanding of the link between an ultrasonic indication and flaw size. Some existing methods at Rolls-Royce use target defects of a known size and metal path through flat surfaces to create a Distance Amplitude Curve (DAC) that can be used to accurately size flaws. This study investigated a DAC equivalent for surface-adaptive TFM techniques applied through non-planar surfaces. There was business interest in development of this technique, and also in its delivery by use of general purpose robotic manipulators. Firstly, a robotic inspection process was developed, and a C-scan was conducted on an irregular titanium plate. cueART, software developed by the University of Strathclyde was adapted to create a TFM C-scan. Results were found to be comparable to an existing production inspection process. A series of curved test pieces were manufactured and target Flat-Bottomed Hole (FBH) defects were added. BRAIN, software developed by Bristol university, was adapted and used with equipment at Rolls-Royce to conduct TFM C-scans. DAC curves were generated experimentally for a test inspection, showing convex radii from 10 to 40 mm led to a drop of 2 dB, and concave 10 dB. This was repeated at various depths to produce multiple DAC curves. Modelling techniques for these experimental cases were developed, finding that a 2D finite element model, and 3D CIVA model followed a similar trend to the DAC. Modelling was used to extend results to produce a map of peak flaw signal through a curved surface. An experimental study of flat, rough surfaces showed that an Ra of 12 ?m led to a 6.4 dB reduction in peak TFM signal, and13.2 dB reduction in signal to noise ratio."]},{"key":"dc:title","label":"Title","values":["Mapping totally-focused flaw signal variation introduced by interface curvature in ultrasonic array inspection"]}]}],"canonical_facts":{"dc:contributor.advisor":["Pierce, Gareth"],"dc:creator":["Brown, Roy"],"dc:creator.authoridentifier":["201385909"],"dc:date":["2019"],"dc:date.issued":["2019"],"dc:description":["\"Engineering Doctorate in Non-Destructive Evaluation\" -- title page.","This thesis documents the use of the Total Focusing Method (TFM) for performing ultrasonic C-scans of components with irregular and curved surfaces. Ultrasonic inspection depends on an understanding of the link between an ultrasonic indication and flaw size. Some existing methods at Rolls-Royce use target defects of a known size and metal path through flat surfaces to create a Distance Amplitude Curve (DAC) that can be used to accurately size flaws. This study investigated a DAC equivalent for surface-adaptive TFM techniques applied through non-planar surfaces. There was business interest in development of this technique, and also in its delivery by use of general purpose robotic manipulators. Firstly, a robotic inspection process was developed, and a C-scan was conducted on an irregular titanium plate. cueART, software developed by the University of Strathclyde was adapted to create a TFM C-scan. Results were found to be comparable to an existing production inspection process. A series of curved test pieces were manufactured and target Flat-Bottomed Hole (FBH) defects were added. BRAIN, software developed by Bristol university, was adapted and used with equipment at Rolls-Royce to conduct TFM C-scans. DAC curves were generated experimentally for a test inspection, showing convex radii from 10 to 40 mm led to a drop of 2 dB, and concave 10 dB. This was repeated at various depths to produce multiple DAC curves. Modelling techniques for these experimental cases were developed, finding that a 2D finite element model, and 3D CIVA model followed a similar trend to the DAC. Modelling was used to extend results to produce a map of peak flaw signal through a curved surface. An experimental study of flat, rough surfaces showed that an Ra of 12 ?m led to a 6.4 dB reduction in peak TFM signal, and13.2 dB reduction in signal to noise ratio."],"dc:description.abstract":["This thesis documents the use of the Total Focusing Method (TFM) for performing ultrasonic C-scans of components with irregular and curved surfaces. Ultrasonic inspection depends on an understanding of the link between an ultrasonic indication and flaw size. Some existing methods at Rolls-Royce use target defects of a known size and metal path through flat surfaces to create a Distance Amplitude Curve (DAC) that can be used to accurately size flaws. This study investigated a DAC equivalent for surface-adaptive TFM techniques applied through non-planar surfaces. There was business interest in development of this technique, and also in its delivery by use of general purpose robotic manipulators. Firstly, a robotic inspection process was developed, and a C-scan was conducted on an irregular titanium plate. cueART, software developed by the University of Strathclyde was adapted to create a TFM C-scan. Results were found to be comparable to an existing production inspection process. A series of curved test pieces were manufactured and target Flat-Bottomed Hole (FBH) defects were added. BRAIN, software developed by Bristol university, was adapted and used with equipment at Rolls-Royce to conduct TFM C-scans. DAC curves were generated experimentally for a test inspection, showing convex radii from 10 to 40 mm led to a drop of 2 dB, and concave 10 dB. This was repeated at various depths to produce multiple DAC curves. Modelling techniques for these experimental cases were developed, finding that a 2D finite element model, and 3D CIVA model followed a similar trend to the DAC. Modelling was used to extend results to produce a map of peak flaw signal through a curved surface. An experimental study of flat, rough surfaces showed that an Ra of 12 ?m led to a 6.4 dB reduction in peak TFM signal, and13.2 dB reduction in signal to noise ratio."],"dc:identifier":["T15479"],"dc:identifier.doi":["10.48730/am4h-hk33"],"dc:identifier.uri":["https://stax.strath.ac.uk/concern/theses/cj82k7327"],"dc:publisher.department":["Department of Electronic and Electrical Engineering"],"dc:publisher.institution":["University of Strathclyde"],"dc:relation.uri":["https://stax.strath.ac.uk/downloads/jw827c105"],"dc:rights.uri":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"dc:title":["Mapping totally-focused flaw signal variation introduced by interface curvature in ultrasonic array inspection"],"dc:type.qualificationlevel":["doctoral-pg"],"dc:type.qualificationname":["engd"],"dc:type.uri":["http://purl.org/coar/resource_type/c_db06"]},"updated_at":"2026-11-19T13:55:43Z"}