{"id":{"repo_id":"strathclyde","oai_identifier":"oai:strathclyde:fn106z69m"},"canonical_url":"https://search.ndltd.org/etd/strathclyde/oai:strathclyde:fn106z69m","repository":{"repo_id":"strathclyde","name":"University of Strathclyde","base_url":"https://stax.strath.ac.uk/catalog/oai"},"display":{"title":"Developing resilient infrastructure for low-carbon heating : concrete linings for underground thermal energy storage (UTES) system","abstract":"Underground thermal energy storage (UTES) systems offer a promising pathway for large-scale seasonal energy storage. However, the long-term structural performance and environmental impacts of subsurface infrastructure remain insufficiently understood. In mine-based UTES, shaft linings are subjected to combined geostatic and thermo-mechanical loading. At the same time, they influence operational heat losses. Material selection is critical for both system reliability and sustainability. This thesis investigates the mechanical, thermal, and environmental performance of concrete shaft lining materials for UTES. It places particular emphasis on a hybrid fibre reinforced concrete incorporating basalt and polypropylene fibres.An experimental programme characterised compressive strength, splitting tensile behaviour, crack-control response, and thermal conductivity. It is considered conventional, nominal, and hybrid fibre-reinforced concrete mixes representative of UTES shaft linings. Results show that fibre reinforcement alters failure mechanisms and cracking behaviour. This change promotes improved stress redistribution and reduces brittleness. Fibre reinforcement also influences thermal conductivity due to changes in matrix densification and interfacial bonding. These findings highlight trade-offs between mechanical performance enhancement and thermal behaviour that directly affect UTES operation.A UTES-specific life-cycle assessment (LCA) framework was developed to assess the environmental implications of these material-level differences. The analysis used a cradle-to-operation system boundary (A1–A3 + B1). Experimentally measured thermal conductivity values were included in use-phase modelling to quantify operational heat losses from shaft linings. LCA results indicate that raw material production, particularly cement manufacture, dominates environmental impacts. Use-phase impacts are sensitive to assumptions about lining thermal performance and energy supply. The analysis reveals trade-offs between increased embodied emissions from fibre reinforcement and changes in operational energy demand. The novelty of this research is not in developing a new LCA theory. Instead, it lies in creating a UTES-specific assessment framework that integrates experimental material performance with system-level environmental evaluation. By linking material-scale behaviour to operational and environmental outcomes, this thesis offers a stronger basis for evaluating and comparing lining materials for sustainable underground thermal energy storage systems.","abstract_html":"Underground thermal energy storage (UTES) systems offer a promising pathway for large-scale seasonal energy storage. However, the long-term structural performance and environmental impacts of subsurface infrastructure remain insufficiently understood. In mine-based UTES, shaft linings are subjected to combined geostatic and thermo-mechanical loading. At the same time, they influence operational heat losses. Material selection is critical for both system reliability and sustainability. This thesis investigates the mechanical, thermal, and environmental performance of concrete shaft lining materials for UTES. It places particular emphasis on a hybrid fibre reinforced concrete incorporating basalt and polypropylene fibres.An experimental programme characterised compressive strength, splitting tensile behaviour, crack-control response, and thermal conductivity. It is considered conventional, nominal, and hybrid fibre-reinforced concrete mixes representative of UTES shaft linings. Results show that fibre reinforcement alters failure mechanisms and cracking behaviour. This change promotes improved stress redistribution and reduces brittleness. Fibre reinforcement also influences thermal conductivity due to changes in matrix densification and interfacial bonding. These findings highlight trade-offs between mechanical performance enhancement and thermal behaviour that directly affect UTES operation.A UTES-specific life-cycle assessment (LCA) framework was developed to assess the environmental implications of these material-level differences. The analysis used a cradle-to-operation system boundary (A1–A3 + B1). Experimentally measured thermal conductivity values were included in use-phase modelling to quantify operational heat losses from shaft linings. LCA results indicate that raw material production, particularly cement manufacture, dominates environmental impacts. Use-phase impacts are sensitive to assumptions about lining thermal performance and energy supply. The analysis reveals trade-offs between increased embodied emissions from fibre reinforcement and changes in operational energy demand. The novelty of this research is not in developing a new LCA theory. Instead, it lies in creating a UTES-specific assessment framework that integrates experimental material performance with system-level environmental evaluation. By linking material-scale behaviour to operational and environmental outcomes, this thesis offers a stronger basis for evaluating and comparing lining materials for sustainable underground thermal energy storage systems.","abstract_has_math":false,"creators":["Essa, Ashraf"],"institution":"University of Strathclyde","degree_name":"phd","degree_level":"doctoral-pg","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Yang, Shangtong"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-25T20:41:13Z","subjects":[],"languages":[],"rights":[],"rights_urls":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/fn106z69m"],"render_values":[{"text":"https://stax.strath.ac.uk/concern/theses/fn106z69m","href":"https://stax.strath.ac.uk/concern/theses/fn106z69m","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["T18103"],"render_values":[{"text":"T18103","href":null,"code":true}]}],"person_identifier_entries":[{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202288247"],"render_values":[{"text":"202288247","href":null,"code":true}]}]},"links":{"outbound_url":"https://doi.org/10.48730/0ceq-he88","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.48730/0ceq-he88","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astrathclyde%3Aoai%3Astrathclyde%3Afn106z69m","prefix":"oai_dc"},"source_record":{"url":"https://stax.strath.ac.uk/catalog/oai?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Astrathclyde%3Afn106z69m","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yang, Shangtong"]},{"key":"dc:creator","label":"Author","values":["Essa, Ashraf"]},{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202288247"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Civil and Environmental Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Strathclyde"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://stax.strath.ac.uk/downloads/bv73c1191"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral-pg"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]},{"key":"dc:type.uri","label":"Dc Type URI","values":["http://purl.org/coar/resource_type/c_db06"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://stax.strath.ac.uk/thesis_copyright_statement/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["T18103"]},{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/0ceq-he88"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/fn106z69m"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Underground thermal energy storage (UTES) systems offer a promising pathway for large-scale seasonal energy storage. However, the long-term structural performance and environmental impacts of subsurface infrastructure remain insufficiently understood. In mine-based UTES, shaft linings are subjected to combined geostatic and thermo-mechanical loading. At the same time, they influence operational heat losses. Material selection is critical for both system reliability and sustainability. This thesis investigates the mechanical, thermal, and environmental performance of concrete shaft lining materials for UTES. It places particular emphasis on a hybrid fibre reinforced concrete incorporating basalt and polypropylene fibres.An experimental programme characterised compressive strength, splitting tensile behaviour, crack-control response, and thermal conductivity. It is considered conventional, nominal, and hybrid fibre-reinforced concrete mixes representative of UTES shaft linings. Results show that fibre reinforcement alters failure mechanisms and cracking behaviour. This change promotes improved stress redistribution and reduces brittleness. Fibre reinforcement also influences thermal conductivity due to changes in matrix densification and interfacial bonding. These findings highlight trade-offs between mechanical performance enhancement and thermal behaviour that directly affect UTES operation.A UTES-specific life-cycle assessment (LCA) framework was developed to assess the environmental implications of these material-level differences. The analysis used a cradle-to-operation system boundary (A1–A3 + B1). Experimentally measured thermal conductivity values were included in use-phase modelling to quantify operational heat losses from shaft linings. LCA results indicate that raw material production, particularly cement manufacture, dominates environmental impacts. Use-phase impacts are sensitive to assumptions about lining thermal performance and energy supply. The analysis reveals trade-offs between increased embodied emissions from fibre reinforcement and changes in operational energy demand. The novelty of this research is not in developing a new LCA theory. Instead, it lies in creating a UTES-specific assessment framework that integrates experimental material performance with system-level environmental evaluation. By linking material-scale behaviour to operational and environmental outcomes, this thesis offers a stronger basis for evaluating and comparing lining materials for sustainable underground thermal energy storage systems."]},{"key":"dc:description.abstract","label":"Abstract","values":["Underground thermal energy storage (UTES) systems offer a promising pathway for large-scale seasonal energy storage. However, the long-term structural performance and environmental impacts of subsurface infrastructure remain insufficiently understood. In mine-based UTES, shaft linings are subjected to combined geostatic and thermo-mechanical loading. At the same time, they influence operational heat losses. Material selection is critical for both system reliability and sustainability. This thesis investigates the mechanical, thermal, and environmental performance of concrete shaft lining materials for UTES. It places particular emphasis on a hybrid fibre reinforced concrete incorporating basalt and polypropylene fibres.An experimental programme characterised compressive strength, splitting tensile behaviour, crack-control response, and thermal conductivity. It is considered conventional, nominal, and hybrid fibre-reinforced concrete mixes representative of UTES shaft linings. Results show that fibre reinforcement alters failure mechanisms and cracking behaviour. This change promotes improved stress redistribution and reduces brittleness. Fibre reinforcement also influences thermal conductivity due to changes in matrix densification and interfacial bonding. These findings highlight trade-offs between mechanical performance enhancement and thermal behaviour that directly affect UTES operation.A UTES-specific life-cycle assessment (LCA) framework was developed to assess the environmental implications of these material-level differences. The analysis used a cradle-to-operation system boundary (A1–A3 + B1). Experimentally measured thermal conductivity values were included in use-phase modelling to quantify operational heat losses from shaft linings. LCA results indicate that raw material production, particularly cement manufacture, dominates environmental impacts. Use-phase impacts are sensitive to assumptions about lining thermal performance and energy supply. The analysis reveals trade-offs between increased embodied emissions from fibre reinforcement and changes in operational energy demand. The novelty of this research is not in developing a new LCA theory. Instead, it lies in creating a UTES-specific assessment framework that integrates experimental material performance with system-level environmental evaluation. By linking material-scale behaviour to operational and environmental outcomes, this thesis offers a stronger basis for evaluating and comparing lining materials for sustainable underground thermal energy storage systems."]},{"key":"dc:title","label":"Title","values":["Developing resilient infrastructure for low-carbon heating : concrete linings for underground thermal energy storage (UTES) system"]}]}],"canonical_facts":{"dc:contributor.advisor":["Yang, Shangtong"],"dc:creator":["Essa, Ashraf"],"dc:creator.authoridentifier":["202288247"],"dc:date.issued":["2026"],"dc:description":["Underground thermal energy storage (UTES) systems offer a promising pathway for large-scale seasonal energy storage. However, the long-term structural performance and environmental impacts of subsurface infrastructure remain insufficiently understood. In mine-based UTES, shaft linings are subjected to combined geostatic and thermo-mechanical loading. At the same time, they influence operational heat losses. Material selection is critical for both system reliability and sustainability. This thesis investigates the mechanical, thermal, and environmental performance of concrete shaft lining materials for UTES. It places particular emphasis on a hybrid fibre reinforced concrete incorporating basalt and polypropylene fibres.An experimental programme characterised compressive strength, splitting tensile behaviour, crack-control response, and thermal conductivity. It is considered conventional, nominal, and hybrid fibre-reinforced concrete mixes representative of UTES shaft linings. Results show that fibre reinforcement alters failure mechanisms and cracking behaviour. This change promotes improved stress redistribution and reduces brittleness. Fibre reinforcement also influences thermal conductivity due to changes in matrix densification and interfacial bonding. These findings highlight trade-offs between mechanical performance enhancement and thermal behaviour that directly affect UTES operation.A UTES-specific life-cycle assessment (LCA) framework was developed to assess the environmental implications of these material-level differences. The analysis used a cradle-to-operation system boundary (A1–A3 + B1). Experimentally measured thermal conductivity values were included in use-phase modelling to quantify operational heat losses from shaft linings. LCA results indicate that raw material production, particularly cement manufacture, dominates environmental impacts. Use-phase impacts are sensitive to assumptions about lining thermal performance and energy supply. The analysis reveals trade-offs between increased embodied emissions from fibre reinforcement and changes in operational energy demand. The novelty of this research is not in developing a new LCA theory. Instead, it lies in creating a UTES-specific assessment framework that integrates experimental material performance with system-level environmental evaluation. By linking material-scale behaviour to operational and environmental outcomes, this thesis offers a stronger basis for evaluating and comparing lining materials for sustainable underground thermal energy storage systems."],"dc:description.abstract":["Underground thermal energy storage (UTES) systems offer a promising pathway for large-scale seasonal energy storage. However, the long-term structural performance and environmental impacts of subsurface infrastructure remain insufficiently understood. In mine-based UTES, shaft linings are subjected to combined geostatic and thermo-mechanical loading. At the same time, they influence operational heat losses. Material selection is critical for both system reliability and sustainability. This thesis investigates the mechanical, thermal, and environmental performance of concrete shaft lining materials for UTES. It places particular emphasis on a hybrid fibre reinforced concrete incorporating basalt and polypropylene fibres.An experimental programme characterised compressive strength, splitting tensile behaviour, crack-control response, and thermal conductivity. It is considered conventional, nominal, and hybrid fibre-reinforced concrete mixes representative of UTES shaft linings. Results show that fibre reinforcement alters failure mechanisms and cracking behaviour. This change promotes improved stress redistribution and reduces brittleness. Fibre reinforcement also influences thermal conductivity due to changes in matrix densification and interfacial bonding. These findings highlight trade-offs between mechanical performance enhancement and thermal behaviour that directly affect UTES operation.A UTES-specific life-cycle assessment (LCA) framework was developed to assess the environmental implications of these material-level differences. The analysis used a cradle-to-operation system boundary (A1–A3 + B1). Experimentally measured thermal conductivity values were included in use-phase modelling to quantify operational heat losses from shaft linings. LCA results indicate that raw material production, particularly cement manufacture, dominates environmental impacts. Use-phase impacts are sensitive to assumptions about lining thermal performance and energy supply. The analysis reveals trade-offs between increased embodied emissions from fibre reinforcement and changes in operational energy demand. The novelty of this research is not in developing a new LCA theory. Instead, it lies in creating a UTES-specific assessment framework that integrates experimental material performance with system-level environmental evaluation. By linking material-scale behaviour to operational and environmental outcomes, this thesis offers a stronger basis for evaluating and comparing lining materials for sustainable underground thermal energy storage systems."],"dc:identifier":["T18103"],"dc:identifier.doi":["10.48730/0ceq-he88"],"dc:identifier.uri":["https://stax.strath.ac.uk/concern/theses/fn106z69m"],"dc:publisher.department":["Department of Civil and Environmental Engineering"],"dc:publisher.institution":["University of Strathclyde"],"dc:relation.uri":["https://stax.strath.ac.uk/downloads/bv73c1191"],"dc:rights.uri":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"dc:title":["Developing resilient infrastructure for low-carbon heating : concrete linings for underground thermal energy storage (UTES) system"],"dc:type.qualificationlevel":["doctoral-pg"],"dc:type.qualificationname":["phd"],"dc:type.uri":["http://purl.org/coar/resource_type/c_db06"]},"updated_at":"2026-11-25T20:41:13Z"}