{"id":{"repo_id":"strathclyde","oai_identifier":"oai:strathclyde:g158bj11q"},"canonical_url":"https://search.ndltd.org/etd/strathclyde/oai:strathclyde:g158bj11q","repository":{"repo_id":"strathclyde","name":"University of Strathclyde","base_url":"https://stax.strath.ac.uk/catalog/oai"},"display":{"title":"µLED arrays for optogenetic cortical surface stimulation","abstract":"Cortical implants are a translational neurotechnology, already transforming the lives of patients with debilitating neurodegenerative conditions. One application of these devices areas a cortical stimulator to restore lost sensation, and specifically there is the possibility torestore lost hearing through stimulation of the auditory cortex, motivating the work in thisthesis. Here, optogenetic cortical implants have been developed based on custom-fabricatedarrays of 100 µLEDs (micro-light emitting diodes). These devices can deliver spatiotemporaloptical stimulation across the surface of the cortex. A packaging process has been developedintegrating the devices into flexible systems, enabling chronic implantation and stable monthslong experiments in the mouse model. Extensive laboratory characterisation and modellinghas established an operational framework for the devices and validated them for long-termimplantation. These devices have enabled in-vivo experiments with simultaneous optogeneticstimulation of the auditory cortex with electrophysiology recording, as well as behaviouralexperiments in freely-moving mice. These experiments have allowed a stimulation thresholdand spatial resolution to be estimated for the devices, informing future experiments that integrate novel deep learning models for meaningful information transfer to the auditory cortex.Lastly, an electronic controller system was developed to drive the devices in-vivo, enablingexperiments involving sophisticated spatio-temporal stimulation patterns and closed-loopcontrol.","abstract_html":"Cortical implants are a translational neurotechnology, already transforming the lives of patients with debilitating neurodegenerative conditions. One application of these devices areas a cortical stimulator to restore lost sensation, and specifically there is the possibility torestore lost hearing through stimulation of the auditory cortex, motivating the work in thisthesis. Here, optogenetic cortical implants have been developed based on custom-fabricatedarrays of 100 µLEDs (micro-light emitting diodes). These devices can deliver spatiotemporaloptical stimulation across the surface of the cortex. A packaging process has been developedintegrating the devices into flexible systems, enabling chronic implantation and stable monthslong experiments in the mouse model. Extensive laboratory characterisation and modellinghas established an operational framework for the devices and validated them for long-termimplantation. These devices have enabled in-vivo experiments with simultaneous optogeneticstimulation of the auditory cortex with electrophysiology recording, as well as behaviouralexperiments in freely-moving mice. These experiments have allowed a stimulation thresholdand spatial resolution to be estimated for the devices, informing future experiments that integrate novel deep learning models for meaningful information transfer to the auditory cortex.Lastly, an electronic controller system was developed to drive the devices in-vivo, enablingexperiments involving sophisticated spatio-temporal stimulation patterns and closed-loopcontrol.","abstract_has_math":false,"creators":["Greer, Ryan"],"institution":"University of Strathclyde","degree_name":"phd","degree_level":"doctoral-pg","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Mathieson, Keith, Dr."],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-25T20:41:35Z","subjects":[],"languages":[],"rights":[],"rights_urls":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/g158bj11q"],"render_values":[{"text":"https://stax.strath.ac.uk/concern/theses/g158bj11q","href":"https://stax.strath.ac.uk/concern/theses/g158bj11q","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["T18208"],"render_values":[{"text":"T18208","href":null,"code":true}]}],"person_identifier_entries":[{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202164606"],"render_values":[{"text":"202164606","href":null,"code":true}]}]},"links":{"outbound_url":"https://doi.org/10.48730/44m3-3d26","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.48730/44m3-3d26","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astrathclyde%3Aoai%3Astrathclyde%3Ag158bj11q","prefix":"oai_dc"},"source_record":{"url":"https://stax.strath.ac.uk/catalog/oai?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Astrathclyde%3Ag158bj11q","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mathieson, Keith, Dr."]},{"key":"dc:creator","label":"Author","values":["Greer, Ryan"]},{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202164606"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2026"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Neurophotonics Group","Department of Physics"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Strathclyde"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://stax.strath.ac.uk/downloads/jd472x095"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral-pg"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]},{"key":"dc:type.uri","label":"Dc Type URI","values":["http://purl.org/coar/resource_type/c_db06"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://stax.strath.ac.uk/thesis_copyright_statement/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["T18208"]},{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/44m3-3d26"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/g158bj11q"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Cortical implants are a translational neurotechnology, already transforming the lives of patients with debilitating neurodegenerative conditions. One application of these devices areas a cortical stimulator to restore lost sensation, and specifically there is the possibility torestore lost hearing through stimulation of the auditory cortex, motivating the work in thisthesis. Here, optogenetic cortical implants have been developed based on custom-fabricatedarrays of 100 µLEDs (micro-light emitting diodes). These devices can deliver spatiotemporaloptical stimulation across the surface of the cortex. A packaging process has been developedintegrating the devices into flexible systems, enabling chronic implantation and stable monthslong experiments in the mouse model. Extensive laboratory characterisation and modellinghas established an operational framework for the devices and validated them for long-termimplantation. These devices have enabled in-vivo experiments with simultaneous optogeneticstimulation of the auditory cortex with electrophysiology recording, as well as behaviouralexperiments in freely-moving mice. These experiments have allowed a stimulation thresholdand spatial resolution to be estimated for the devices, informing future experiments that integrate novel deep learning models for meaningful information transfer to the auditory cortex.Lastly, an electronic controller system was developed to drive the devices in-vivo, enablingexperiments involving sophisticated spatio-temporal stimulation patterns and closed-loopcontrol."]},{"key":"dc:description.abstract","label":"Abstract","values":["Cortical implants are a translational neurotechnology, already transforming the lives of patients with debilitating neurodegenerative conditions. One application of these devices areas a cortical stimulator to restore lost sensation, and specifically there is the possibility torestore lost hearing through stimulation of the auditory cortex, motivating the work in thisthesis. Here, optogenetic cortical implants have been developed based on custom-fabricatedarrays of 100 µLEDs (micro-light emitting diodes). These devices can deliver spatiotemporaloptical stimulation across the surface of the cortex. A packaging process has been developedintegrating the devices into flexible systems, enabling chronic implantation and stable monthslong experiments in the mouse model. Extensive laboratory characterisation and modellinghas established an operational framework for the devices and validated them for long-termimplantation. These devices have enabled in-vivo experiments with simultaneous optogeneticstimulation of the auditory cortex with electrophysiology recording, as well as behaviouralexperiments in freely-moving mice. These experiments have allowed a stimulation thresholdand spatial resolution to be estimated for the devices, informing future experiments that integrate novel deep learning models for meaningful information transfer to the auditory cortex.Lastly, an electronic controller system was developed to drive the devices in-vivo, enablingexperiments involving sophisticated spatio-temporal stimulation patterns and closed-loopcontrol."]},{"key":"dc:title","label":"Title","values":["µLED arrays for optogenetic cortical surface stimulation"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mathieson, Keith, Dr."],"dc:creator":["Greer, Ryan"],"dc:creator.authoridentifier":["202164606"],"dc:date.issued":["2026"],"dc:description":["Cortical implants are a translational neurotechnology, already transforming the lives of patients with debilitating neurodegenerative conditions. One application of these devices areas a cortical stimulator to restore lost sensation, and specifically there is the possibility torestore lost hearing through stimulation of the auditory cortex, motivating the work in thisthesis. Here, optogenetic cortical implants have been developed based on custom-fabricatedarrays of 100 µLEDs (micro-light emitting diodes). These devices can deliver spatiotemporaloptical stimulation across the surface of the cortex. A packaging process has been developedintegrating the devices into flexible systems, enabling chronic implantation and stable monthslong experiments in the mouse model. Extensive laboratory characterisation and modellinghas established an operational framework for the devices and validated them for long-termimplantation. These devices have enabled in-vivo experiments with simultaneous optogeneticstimulation of the auditory cortex with electrophysiology recording, as well as behaviouralexperiments in freely-moving mice. These experiments have allowed a stimulation thresholdand spatial resolution to be estimated for the devices, informing future experiments that integrate novel deep learning models for meaningful information transfer to the auditory cortex.Lastly, an electronic controller system was developed to drive the devices in-vivo, enablingexperiments involving sophisticated spatio-temporal stimulation patterns and closed-loopcontrol."],"dc:description.abstract":["Cortical implants are a translational neurotechnology, already transforming the lives of patients with debilitating neurodegenerative conditions. One application of these devices areas a cortical stimulator to restore lost sensation, and specifically there is the possibility torestore lost hearing through stimulation of the auditory cortex, motivating the work in thisthesis. Here, optogenetic cortical implants have been developed based on custom-fabricatedarrays of 100 µLEDs (micro-light emitting diodes). These devices can deliver spatiotemporaloptical stimulation across the surface of the cortex. A packaging process has been developedintegrating the devices into flexible systems, enabling chronic implantation and stable monthslong experiments in the mouse model. Extensive laboratory characterisation and modellinghas established an operational framework for the devices and validated them for long-termimplantation. These devices have enabled in-vivo experiments with simultaneous optogeneticstimulation of the auditory cortex with electrophysiology recording, as well as behaviouralexperiments in freely-moving mice. These experiments have allowed a stimulation thresholdand spatial resolution to be estimated for the devices, informing future experiments that integrate novel deep learning models for meaningful information transfer to the auditory cortex.Lastly, an electronic controller system was developed to drive the devices in-vivo, enablingexperiments involving sophisticated spatio-temporal stimulation patterns and closed-loopcontrol."],"dc:identifier":["T18208"],"dc:identifier.doi":["10.48730/44m3-3d26"],"dc:identifier.uri":["https://stax.strath.ac.uk/concern/theses/g158bj11q"],"dc:publisher.department":["Neurophotonics Group","Department of Physics"],"dc:publisher.institution":["University of Strathclyde"],"dc:relation.uri":["https://stax.strath.ac.uk/downloads/jd472x095"],"dc:rights.uri":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"dc:title":["µLED arrays for optogenetic cortical surface stimulation"],"dc:type.qualificationlevel":["doctoral-pg"],"dc:type.qualificationname":["phd"],"dc:type.uri":["http://purl.org/coar/resource_type/c_db06"]},"updated_at":"2026-11-25T20:41:35Z"}