{"id":{"repo_id":"strathclyde","oai_identifier":"oai:strathclyde:m613mx695"},"canonical_url":"https://search.ndltd.org/etd/strathclyde/oai:strathclyde:m613mx695","repository":{"repo_id":"strathclyde","name":"University of Strathclyde","base_url":"https://stax.strath.ac.uk/catalog/oai"},"display":{"title":"Towards a tri-leaflet polyurethane heart valve prothesis","abstract":"Given the poor durability of bioprosthetic heart valves and thrombogenicity of mechanical valves, recent attention has been directed towards synthetic leaflet valves. The work of this thesis forms part of a project to develop a tri-leaflet polyurethane heart valve prosthesis. Two aspects have been addressed: in vitro valve function and durability test methods, and fabrication techniques for polyurethane valves. Existing in vitro valve testing facilities, comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more efficiently and reliably assessed, and also provides a means for characterising the pulse duplicator and its transducers. Accelerated fatigue testing facilities have been similarly enhanced by the introduction of a computerised data acquisition system. In order to exploit the design potential offered by the use of a synthetic material, an integrated CAD/CAM system has been developed for producing sculptured valve formers. Such formers have been incorporated into injection moulding tools for tri-leaflet polyurethane valves. Polyurethane valves have been moulded, but to date not with sufficiently thin leaflets: the required leaflet thickness (< 150 gm) results in a mould cavity which presents an enormous resistance to flow in the injection moulding process. However, a finite element-based mathematical model has been used to simulate the flow of molten polyurethane into the mould cavity and initial results suggest that it should indeed be possible to injection mould a polyurethane valve and a practicable means of achieving this has been identified. The sculptured formers incorporated into the injection moulding tools have also been used to create dip moulded tri-leaflet polyurethane valves. These dip moulded valves, though difficult to produce consistently, function reasonably well in the pulse duplicator and accelerated fatigue tests are in progress.","abstract_html":"Given the poor durability of bioprosthetic heart valves and thrombogenicity of mechanical valves, recent attention has been directed towards synthetic leaflet valves. The work of this thesis forms part of a project to develop a tri-leaflet polyurethane heart valve prosthesis. Two aspects have been addressed: in vitro valve function and durability test methods, and fabrication techniques for polyurethane valves. Existing in vitro valve testing facilities, comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more efficiently and reliably assessed, and also provides a means for characterising the pulse duplicator and its transducers. Accelerated fatigue testing facilities have been similarly enhanced by the introduction of a computerised data acquisition system. In order to exploit the design potential offered by the use of a synthetic material, an integrated CAD/CAM system has been developed for producing sculptured valve formers. Such formers have been incorporated into injection moulding tools for tri-leaflet polyurethane valves. Polyurethane valves have been moulded, but to date not with sufficiently thin leaflets: the required leaflet thickness (&lt; 150 gm) results in a mould cavity which presents an enormous resistance to flow in the injection moulding process. However, a finite element-based mathematical model has been used to simulate the flow of molten polyurethane into the mould cavity and initial results suggest that it should indeed be possible to injection mould a polyurethane valve and a practicable means of achieving this has been identified. The sculptured formers incorporated into the injection moulding tools have also been used to create dip moulded tri-leaflet polyurethane valves. These dip moulded valves, though difficult to produce consistently, function reasonably well in the pulse duplicator and accelerated fatigue tests are in progress.","abstract_has_math":false,"creators":["Mackay, Tom G."],"institution":"University of Strathclyde","degree_name":"phd","degree_level":"doctoral-pg","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-19T15:06:01Z","subjects":[],"languages":[],"rights":[],"rights_urls":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/6vw8-bw82"],"render_values":[{"text":"10.48730/6vw8-bw82","href":"https://doi.org/10.48730/6vw8-bw82","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.324108","T7473"],"render_values":[{"text":"uk.bl.ethos.324108","href":null,"code":true},{"text":"T7473","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stax.strath.ac.uk/concern/theses/m613mx695","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stax.strath.ac.uk/concern/theses/m613mx695","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stax.strath.ac.uk/catalog/oai?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Astrathclyde%3Am613mx695","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mackay, Tom G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1992"]},{"key":"dc:date.issued","label":"Date","values":["1992"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Bioengineering Unit"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Strathclyde"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://stax.strath.ac.uk/downloads/pz50gw33g"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral-pg"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]},{"key":"dc:type.uri","label":"Dc Type URI","values":["http://purl.org/coar/resource_type/c_db06"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://stax.strath.ac.uk/thesis_copyright_statement/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["uk.bl.ethos.324108","T7473"]},{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/6vw8-bw82"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/m613mx695"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Given the poor durability of bioprosthetic heart valves and thrombogenicity of mechanical valves, recent attention has been directed towards synthetic leaflet valves. The work of this thesis forms part of a project to develop a tri-leaflet polyurethane heart valve prosthesis. Two aspects have been addressed: in vitro valve function and durability test methods, and fabrication techniques for polyurethane valves. Existing in vitro valve testing facilities, comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more efficiently and reliably assessed, and also provides a means for characterising the pulse duplicator and its transducers. Accelerated fatigue testing facilities have been similarly enhanced by the introduction of a computerised data acquisition system. In order to exploit the design potential offered by the use of a synthetic material, an integrated CAD/CAM system has been developed for producing sculptured valve formers. Such formers have been incorporated into injection moulding tools for tri-leaflet polyurethane valves. Polyurethane valves have been moulded, but to date not with sufficiently thin leaflets: the required leaflet thickness (< 150 gm) results in a mould cavity which presents an enormous resistance to flow in the injection moulding process. However, a finite element-based mathematical model has been used to simulate the flow of molten polyurethane into the mould cavity and initial results suggest that it should indeed be possible to injection mould a polyurethane valve and a practicable means of achieving this has been identified. The sculptured formers incorporated into the injection moulding tools have also been used to create dip moulded tri-leaflet polyurethane valves. These dip moulded valves, though difficult to produce consistently, function reasonably well in the pulse duplicator and accelerated fatigue tests are in progress."]},{"key":"dc:description.abstract","label":"Abstract","values":["Given the poor durability of bioprosthetic heart valves and thrombogenicity of mechanical valves, recent attention has been directed towards synthetic leaflet valves. The work of this thesis forms part of a project to develop a tri-leaflet polyurethane heart valve prosthesis. Two aspects have been addressed: in vitro valve function and durability test methods, and fabrication techniques for polyurethane valves. Existing in vitro valve testing facilities, comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more efficiently and reliably assessed, and also provides a means for characterising the pulse duplicator and its transducers. Accelerated fatigue testing facilities have been similarly enhanced by the introduction of a computerised data acquisition system. In order to exploit the design potential offered by the use of a synthetic material, an integrated CAD/CAM system has been developed for producing sculptured valve formers. Such formers have been incorporated into injection moulding tools for tri-leaflet polyurethane valves. Polyurethane valves have been moulded, but to date not with sufficiently thin leaflets: the required leaflet thickness (< 150 gm) results in a mould cavity which presents an enormous resistance to flow in the injection moulding process. However, a finite element-based mathematical model has been used to simulate the flow of molten polyurethane into the mould cavity and initial results suggest that it should indeed be possible to injection mould a polyurethane valve and a practicable means of achieving this has been identified. The sculptured formers incorporated into the injection moulding tools have also been used to create dip moulded tri-leaflet polyurethane valves. These dip moulded valves, though difficult to produce consistently, function reasonably well in the pulse duplicator and accelerated fatigue tests are in progress."]},{"key":"dc:title","label":"Title","values":["Towards a tri-leaflet polyurethane heart valve prothesis"]}]}],"canonical_facts":{"dc:creator":["Mackay, Tom G."],"dc:date":["1992"],"dc:date.issued":["1992"],"dc:description":["Given the poor durability of bioprosthetic heart valves and thrombogenicity of mechanical valves, recent attention has been directed towards synthetic leaflet valves. The work of this thesis forms part of a project to develop a tri-leaflet polyurethane heart valve prosthesis. Two aspects have been addressed: in vitro valve function and durability test methods, and fabrication techniques for polyurethane valves. Existing in vitro valve testing facilities, comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more efficiently and reliably assessed, and also provides a means for characterising the pulse duplicator and its transducers. Accelerated fatigue testing facilities have been similarly enhanced by the introduction of a computerised data acquisition system. In order to exploit the design potential offered by the use of a synthetic material, an integrated CAD/CAM system has been developed for producing sculptured valve formers. Such formers have been incorporated into injection moulding tools for tri-leaflet polyurethane valves. Polyurethane valves have been moulded, but to date not with sufficiently thin leaflets: the required leaflet thickness (< 150 gm) results in a mould cavity which presents an enormous resistance to flow in the injection moulding process. However, a finite element-based mathematical model has been used to simulate the flow of molten polyurethane into the mould cavity and initial results suggest that it should indeed be possible to injection mould a polyurethane valve and a practicable means of achieving this has been identified. The sculptured formers incorporated into the injection moulding tools have also been used to create dip moulded tri-leaflet polyurethane valves. These dip moulded valves, though difficult to produce consistently, function reasonably well in the pulse duplicator and accelerated fatigue tests are in progress."],"dc:description.abstract":["Given the poor durability of bioprosthetic heart valves and thrombogenicity of mechanical valves, recent attention has been directed towards synthetic leaflet valves. The work of this thesis forms part of a project to develop a tri-leaflet polyurethane heart valve prosthesis. Two aspects have been addressed: in vitro valve function and durability test methods, and fabrication techniques for polyurethane valves. Existing in vitro valve testing facilities, comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more efficiently and reliably assessed, and also provides a means for characterising the pulse duplicator and its transducers. Accelerated fatigue testing facilities have been similarly enhanced by the introduction of a computerised data acquisition system. In order to exploit the design potential offered by the use of a synthetic material, an integrated CAD/CAM system has been developed for producing sculptured valve formers. Such formers have been incorporated into injection moulding tools for tri-leaflet polyurethane valves. Polyurethane valves have been moulded, but to date not with sufficiently thin leaflets: the required leaflet thickness (< 150 gm) results in a mould cavity which presents an enormous resistance to flow in the injection moulding process. However, a finite element-based mathematical model has been used to simulate the flow of molten polyurethane into the mould cavity and initial results suggest that it should indeed be possible to injection mould a polyurethane valve and a practicable means of achieving this has been identified. The sculptured formers incorporated into the injection moulding tools have also been used to create dip moulded tri-leaflet polyurethane valves. These dip moulded valves, though difficult to produce consistently, function reasonably well in the pulse duplicator and accelerated fatigue tests are in progress."],"dc:identifier":["uk.bl.ethos.324108","T7473"],"dc:identifier.doi":["10.48730/6vw8-bw82"],"dc:identifier.uri":["https://stax.strath.ac.uk/concern/theses/m613mx695"],"dc:publisher.department":["Bioengineering Unit"],"dc:publisher.institution":["University of Strathclyde"],"dc:relation.uri":["https://stax.strath.ac.uk/downloads/pz50gw33g"],"dc:rights.uri":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"dc:title":["Towards a tri-leaflet polyurethane heart valve prothesis"],"dc:type.qualificationlevel":["doctoral-pg"],"dc:type.qualificationname":["phd"],"dc:type.uri":["http://purl.org/coar/resource_type/c_db06"]},"updated_at":"2026-11-19T15:06:01Z"}