{"id":{"repo_id":"strathclyde","oai_identifier":"oai:strathclyde:qn59q4627"},"canonical_url":"https://search.ndltd.org/etd/strathclyde/oai:strathclyde:qn59q4627","repository":{"repo_id":"strathclyde","name":"University of Strathclyde","base_url":"https://stax.strath.ac.uk/catalog/oai"},"display":{"title":"Fabric modelling and effects of fluid flow disruption in endovascular devices","abstract":"Abdominal Aortic Aneurysms (AAA) present a significant health risk due to the risk of rupture, leading to life-changing and potentially fatal complications. Endovascular aneurysm repair (EVAR) using stent grafts has become the preferred treatment method due to its minimallyinvasive nature. However, long-term complications including graft migration, endoleaks andthrombosis continue to occur and often require reintervention. This thesis investigates the mechanical behaviour of the woven biofabric used in stent grafts and its influence on the overallperformance of endovascular devices, with a particular focus on fabric deformation, devicestiffness, and fluid flow disruption.A comprehensive experimental characterisation of the woven bio-fabric was conducted,including testing in the tensile, shear, and bending directions to determine the fabrics mechanical properties under loaded conditions, creating a solid framework for future fabric studies.Finite element models (FEA) were developed through bespoke material models, previouslynot utilised within the field, and validated to simulate the interaction between the fabric andthe nitinol ring scaffold, capturing the complex deformation of the stent graft. Experimentalstudies in representative stent graft devices assessed axial and bending stiffness through novelmethods which open up new avenues in stent graft design and reveal the influence of the fabricproperties on the flexibility and conformance to the arterial wall.To further evaluate the impact of fabric deformation on haemodynamics, computationalfluid dynamics (CFD) simulations were performed, integrating patient-derived geometric variations and in vivo pressure conditions. The study analysed key haemodynamic parameters suchas wall shear stress (WSS), recirculation zones, low flow regions, and other relevant factorslinked to the formation of thrombus. The findings highlighted the role of fabric deformation inaltering local flow conditions.The research outcomes contribute to the advancement of stent graft design by providing adetailed understanding of the mechanical and fluid dynamics within endovascular devices. Thedeveloped modelling framework improves the predictive capabilities for device performance,helping in the development of the next generation of stent grafts with improved hemodynamicefficiency. These insights have direct implications for clinical practice, offering strategies toimprove long-term patient outcomes and following EVAR procedures and reduce postoperativecomplications.","abstract_html":"Abdominal Aortic Aneurysms (AAA) present a significant health risk due to the risk of rupture, leading to life-changing and potentially fatal complications. Endovascular aneurysm repair (EVAR) using stent grafts has become the preferred treatment method due to its minimallyinvasive nature. However, long-term complications including graft migration, endoleaks andthrombosis continue to occur and often require reintervention. This thesis investigates the mechanical behaviour of the woven biofabric used in stent grafts and its influence on the overallperformance of endovascular devices, with a particular focus on fabric deformation, devicestiffness, and fluid flow disruption.A comprehensive experimental characterisation of the woven bio-fabric was conducted,including testing in the tensile, shear, and bending directions to determine the fabrics mechanical properties under loaded conditions, creating a solid framework for future fabric studies.Finite element models (FEA) were developed through bespoke material models, previouslynot utilised within the field, and validated to simulate the interaction between the fabric andthe nitinol ring scaffold, capturing the complex deformation of the stent graft. Experimentalstudies in representative stent graft devices assessed axial and bending stiffness through novelmethods which open up new avenues in stent graft design and reveal the influence of the fabricproperties on the flexibility and conformance to the arterial wall.To further evaluate the impact of fabric deformation on haemodynamics, computationalfluid dynamics (CFD) simulations were performed, integrating patient-derived geometric variations and in vivo pressure conditions. The study analysed key haemodynamic parameters suchas wall shear stress (WSS), recirculation zones, low flow regions, and other relevant factorslinked to the formation of thrombus. The findings highlighted the role of fabric deformation inaltering local flow conditions.The research outcomes contribute to the advancement of stent graft design by providing adetailed understanding of the mechanical and fluid dynamics within endovascular devices. Thedeveloped modelling framework improves the predictive capabilities for device performance,helping in the development of the next generation of stent grafts with improved hemodynamicefficiency. These insights have direct implications for clinical practice, offering strategies toimprove long-term patient outcomes and following EVAR procedures and reduce postoperativecomplications.","abstract_has_math":false,"creators":["Wallace, Lewis"],"institution":"University of Strathclyde","degree_name":"phd","degree_level":"doctoral-pg","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Dempster, William","Nash, David"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-25T20:41:33Z","subjects":[],"languages":[],"rights":[],"rights_urls":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/qn59q4627"],"render_values":[{"text":"https://stax.strath.ac.uk/concern/theses/qn59q4627","href":"https://stax.strath.ac.uk/concern/theses/qn59q4627","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["T17481"],"render_values":[{"text":"T17481","href":null,"code":true}]}],"person_identifier_entries":[{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202190936"],"render_values":[{"text":"202190936","href":null,"code":true}]}]},"links":{"outbound_url":"https://doi.org/10.48730/wzhb-s033","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.48730/wzhb-s033","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Astrathclyde%3Aoai%3Astrathclyde%3Aqn59q4627","prefix":"oai_dc"},"source_record":{"url":"https://stax.strath.ac.uk/catalog/oai?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Astrathclyde%3Aqn59q4627","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Dempster, William","Nash, David"]},{"key":"dc:creator","label":"Author","values":["Wallace, Lewis"]},{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202190936"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Department of Mechanical and Aerospace Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Strathclyde"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://stax.strath.ac.uk/downloads/p8418n99r"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral-pg"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]},{"key":"dc:type.uri","label":"Dc Type URI","values":["http://purl.org/coar/resource_type/c_db06"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://stax.strath.ac.uk/thesis_copyright_statement/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["T17481"]},{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/wzhb-s033"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/qn59q4627"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The stress-strain data in chapter 3 has been redacted at the request of the supplier.","Abdominal Aortic Aneurysms (AAA) present a significant health risk due to the risk of rupture, leading to life-changing and potentially fatal complications. Endovascular aneurysm repair (EVAR) using stent grafts has become the preferred treatment method due to its minimallyinvasive nature. However, long-term complications including graft migration, endoleaks andthrombosis continue to occur and often require reintervention. This thesis investigates the mechanical behaviour of the woven biofabric used in stent grafts and its influence on the overallperformance of endovascular devices, with a particular focus on fabric deformation, devicestiffness, and fluid flow disruption.A comprehensive experimental characterisation of the woven bio-fabric was conducted,including testing in the tensile, shear, and bending directions to determine the fabrics mechanical properties under loaded conditions, creating a solid framework for future fabric studies.Finite element models (FEA) were developed through bespoke material models, previouslynot utilised within the field, and validated to simulate the interaction between the fabric andthe nitinol ring scaffold, capturing the complex deformation of the stent graft. Experimentalstudies in representative stent graft devices assessed axial and bending stiffness through novelmethods which open up new avenues in stent graft design and reveal the influence of the fabricproperties on the flexibility and conformance to the arterial wall.To further evaluate the impact of fabric deformation on haemodynamics, computationalfluid dynamics (CFD) simulations were performed, integrating patient-derived geometric variations and in vivo pressure conditions. The study analysed key haemodynamic parameters suchas wall shear stress (WSS), recirculation zones, low flow regions, and other relevant factorslinked to the formation of thrombus. The findings highlighted the role of fabric deformation inaltering local flow conditions.The research outcomes contribute to the advancement of stent graft design by providing adetailed understanding of the mechanical and fluid dynamics within endovascular devices. Thedeveloped modelling framework improves the predictive capabilities for device performance,helping in the development of the next generation of stent grafts with improved hemodynamicefficiency. These insights have direct implications for clinical practice, offering strategies toimprove long-term patient outcomes and following EVAR procedures and reduce postoperativecomplications."]},{"key":"dc:description.abstract","label":"Abstract","values":["Abdominal Aortic Aneurysms (AAA) present a significant health risk due to the risk of rupture, leading to life-changing and potentially fatal complications. Endovascular aneurysm repair (EVAR) using stent grafts has become the preferred treatment method due to its minimallyinvasive nature. However, long-term complications including graft migration, endoleaks andthrombosis continue to occur and often require reintervention. This thesis investigates the mechanical behaviour of the woven biofabric used in stent grafts and its influence on the overallperformance of endovascular devices, with a particular focus on fabric deformation, devicestiffness, and fluid flow disruption.A comprehensive experimental characterisation of the woven bio-fabric was conducted,including testing in the tensile, shear, and bending directions to determine the fabrics mechanical properties under loaded conditions, creating a solid framework for future fabric studies.Finite element models (FEA) were developed through bespoke material models, previouslynot utilised within the field, and validated to simulate the interaction between the fabric andthe nitinol ring scaffold, capturing the complex deformation of the stent graft. Experimentalstudies in representative stent graft devices assessed axial and bending stiffness through novelmethods which open up new avenues in stent graft design and reveal the influence of the fabricproperties on the flexibility and conformance to the arterial wall.To further evaluate the impact of fabric deformation on haemodynamics, computationalfluid dynamics (CFD) simulations were performed, integrating patient-derived geometric variations and in vivo pressure conditions. The study analysed key haemodynamic parameters suchas wall shear stress (WSS), recirculation zones, low flow regions, and other relevant factorslinked to the formation of thrombus. The findings highlighted the role of fabric deformation inaltering local flow conditions.The research outcomes contribute to the advancement of stent graft design by providing adetailed understanding of the mechanical and fluid dynamics within endovascular devices. Thedeveloped modelling framework improves the predictive capabilities for device performance,helping in the development of the next generation of stent grafts with improved hemodynamicefficiency. These insights have direct implications for clinical practice, offering strategies toimprove long-term patient outcomes and following EVAR procedures and reduce postoperativecomplications."]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["This thesis is currently under moratorium due to copyright restrictions. If you are the author of this thesis, please contact the Library to resolve this issue."]},{"key":"dc:title","label":"Title","values":["Fabric modelling and effects of fluid flow disruption in endovascular devices"]}]}],"canonical_facts":{"dc:contributor.advisor":["Dempster, William","Nash, David"],"dc:creator":["Wallace, Lewis"],"dc:creator.authoridentifier":["202190936"],"dc:date.issued":["2025"],"dc:description":["The stress-strain data in chapter 3 has been redacted at the request of the supplier.","Abdominal Aortic Aneurysms (AAA) present a significant health risk due to the risk of rupture, leading to life-changing and potentially fatal complications. Endovascular aneurysm repair (EVAR) using stent grafts has become the preferred treatment method due to its minimallyinvasive nature. However, long-term complications including graft migration, endoleaks andthrombosis continue to occur and often require reintervention. This thesis investigates the mechanical behaviour of the woven biofabric used in stent grafts and its influence on the overallperformance of endovascular devices, with a particular focus on fabric deformation, devicestiffness, and fluid flow disruption.A comprehensive experimental characterisation of the woven bio-fabric was conducted,including testing in the tensile, shear, and bending directions to determine the fabrics mechanical properties under loaded conditions, creating a solid framework for future fabric studies.Finite element models (FEA) were developed through bespoke material models, previouslynot utilised within the field, and validated to simulate the interaction between the fabric andthe nitinol ring scaffold, capturing the complex deformation of the stent graft. Experimentalstudies in representative stent graft devices assessed axial and bending stiffness through novelmethods which open up new avenues in stent graft design and reveal the influence of the fabricproperties on the flexibility and conformance to the arterial wall.To further evaluate the impact of fabric deformation on haemodynamics, computationalfluid dynamics (CFD) simulations were performed, integrating patient-derived geometric variations and in vivo pressure conditions. The study analysed key haemodynamic parameters suchas wall shear stress (WSS), recirculation zones, low flow regions, and other relevant factorslinked to the formation of thrombus. The findings highlighted the role of fabric deformation inaltering local flow conditions.The research outcomes contribute to the advancement of stent graft design by providing adetailed understanding of the mechanical and fluid dynamics within endovascular devices. Thedeveloped modelling framework improves the predictive capabilities for device performance,helping in the development of the next generation of stent grafts with improved hemodynamicefficiency. These insights have direct implications for clinical practice, offering strategies toimprove long-term patient outcomes and following EVAR procedures and reduce postoperativecomplications."],"dc:description.abstract":["Abdominal Aortic Aneurysms (AAA) present a significant health risk due to the risk of rupture, leading to life-changing and potentially fatal complications. Endovascular aneurysm repair (EVAR) using stent grafts has become the preferred treatment method due to its minimallyinvasive nature. However, long-term complications including graft migration, endoleaks andthrombosis continue to occur and often require reintervention. This thesis investigates the mechanical behaviour of the woven biofabric used in stent grafts and its influence on the overallperformance of endovascular devices, with a particular focus on fabric deformation, devicestiffness, and fluid flow disruption.A comprehensive experimental characterisation of the woven bio-fabric was conducted,including testing in the tensile, shear, and bending directions to determine the fabrics mechanical properties under loaded conditions, creating a solid framework for future fabric studies.Finite element models (FEA) were developed through bespoke material models, previouslynot utilised within the field, and validated to simulate the interaction between the fabric andthe nitinol ring scaffold, capturing the complex deformation of the stent graft. Experimentalstudies in representative stent graft devices assessed axial and bending stiffness through novelmethods which open up new avenues in stent graft design and reveal the influence of the fabricproperties on the flexibility and conformance to the arterial wall.To further evaluate the impact of fabric deformation on haemodynamics, computationalfluid dynamics (CFD) simulations were performed, integrating patient-derived geometric variations and in vivo pressure conditions. The study analysed key haemodynamic parameters suchas wall shear stress (WSS), recirculation zones, low flow regions, and other relevant factorslinked to the formation of thrombus. The findings highlighted the role of fabric deformation inaltering local flow conditions.The research outcomes contribute to the advancement of stent graft design by providing adetailed understanding of the mechanical and fluid dynamics within endovascular devices. Thedeveloped modelling framework improves the predictive capabilities for device performance,helping in the development of the next generation of stent grafts with improved hemodynamicefficiency. These insights have direct implications for clinical practice, offering strategies toimprove long-term patient outcomes and following EVAR procedures and reduce postoperativecomplications."],"dc:identifier":["T17481"],"dc:identifier.doi":["10.48730/wzhb-s033"],"dc:identifier.uri":["https://stax.strath.ac.uk/concern/theses/qn59q4627"],"dc:publisher.department":["Department of Mechanical and Aerospace Engineering"],"dc:publisher.institution":["University of Strathclyde"],"dc:relation.uri":["https://stax.strath.ac.uk/downloads/p8418n99r"],"dc:rights.uri":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"dcterms:accessrights":["This thesis is currently under moratorium due to copyright restrictions. If you are the author of this thesis, please contact the Library to resolve this issue."],"dc:title":["Fabric modelling and effects of fluid flow disruption in endovascular devices"],"dc:type.qualificationlevel":["doctoral-pg"],"dc:type.qualificationname":["phd"],"dc:type.uri":["http://purl.org/coar/resource_type/c_db06"]},"updated_at":"2026-11-25T20:41:33Z"}