{"id":{"repo_id":"strathclyde","oai_identifier":"oai:strathclyde:vm40xs237"},"canonical_url":"https://search.ndltd.org/etd/strathclyde/oai:strathclyde:vm40xs237","repository":{"repo_id":"strathclyde","name":"University of Strathclyde","base_url":"https://stax.strath.ac.uk/catalog/oai"},"display":{"title":"Compact diffuse correlation spectroscopy systems","abstract":"Diffuse correlation spectroscopy (DCS) is a powerful tool for investigating microvascular dynamics in deep tissues. It has been used for non-invasive blood flow assessment at the bedside. This study first provides a thorough literature review on system setups (continuous-wave, frequency-domain, and time-domain) and derive corresponding theoretical models. I then present an innovative deep learning algorithm, DCS-NET, which is easy and robust to train, fast, and insensitive to measurement noise for data processing. The absolute blood flow index (BFi) at different depths with/without measurement noise was calculated, followed by a relative blood flow calculation. I then calculated the intrinsic sensitivity, and calculated BFi with varied optical properties and scalp/skull thicknesses finally. Compared with the semi-infinite, and three-layer fitting methods, I show that the DCS-NET is approximately 17,000 times faster than the traditional three-layer model and 32 times faster than the semi-infinite model, respectively. It provides increased inherent sensitivity to deep tissues compared to fitting methods. DCS-NET demonstrates remarkable noise resilience and is minimally affected by variations in ?a and ?s'. Additionally, we have shown that DCS-NET can extract relative blood flow index (rBFi) with a substantially lower error of 8.35%. In comparison, the semi-infinite and three-layer fitting models produce considerable errors in rBFi, amounting to 43.76% and 19.66%, respectively. Additionally, a DCS prototype is developed by integrating an advanced CMOS single-photon avalanche diode array, which employing a parallel light detection scheme, exhibits exceptional photon-counting throughput. The system tested on a milk phantom, showing SNR gain with the entire sensor is improved nearly 160-fold compared with a single pixel. An in vivo blood occlusion test was also performed. In conclusion, our system works well, and this research can offer peers effective guidance to embark on DCS research.","abstract_html":"Diffuse correlation spectroscopy (DCS) is a powerful tool for investigating microvascular dynamics in deep tissues. It has been used for non-invasive blood flow assessment at the bedside. This study first provides a thorough literature review on system setups (continuous-wave, frequency-domain, and time-domain) and derive corresponding theoretical models. I then present an innovative deep learning algorithm, DCS-NET, which is easy and robust to train, fast, and insensitive to measurement noise for data processing. The absolute blood flow index (BFi) at different depths with/without measurement noise was calculated, followed by a relative blood flow calculation. I then calculated the intrinsic sensitivity, and calculated BFi with varied optical properties and scalp/skull thicknesses finally. Compared with the semi-infinite, and three-layer fitting methods, I show that the DCS-NET is approximately 17,000 times faster than the traditional three-layer model and 32 times faster than the semi-infinite model, respectively. It provides increased inherent sensitivity to deep tissues compared to fitting methods. DCS-NET demonstrates remarkable noise resilience and is minimally affected by variations in ?a and ?s&#x27;. Additionally, we have shown that DCS-NET can extract relative blood flow index (rBFi) with a substantially lower error of 8.35%. In comparison, the semi-infinite and three-layer fitting models produce considerable errors in rBFi, amounting to 43.76% and 19.66%, respectively. Additionally, a DCS prototype is developed by integrating an advanced CMOS single-photon avalanche diode array, which employing a parallel light detection scheme, exhibits exceptional photon-counting throughput. The system tested on a milk phantom, showing SNR gain with the entire sensor is improved nearly 160-fold compared with a single pixel. An in vivo blood occlusion test was also performed. In conclusion, our system works well, and this research can offer peers effective guidance to embark on DCS research.","abstract_has_math":false,"creators":["Wang, Quan"],"institution":"University of Strathclyde","degree_name":"phd","degree_level":"doctoral-pg","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Chen, Yu, 1973 December 28-","Li, David Day-Uei"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T16:21:03Z","subjects":[],"languages":[],"rights":[],"rights_urls":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/jvk7-7f59"],"render_values":[{"text":"10.48730/jvk7-7f59","href":"https://doi.org/10.48730/jvk7-7f59","code":true}]},{"key":"dc:identifier","label":"Identifier","values":["T16929"],"render_values":[{"text":"T16929","href":null,"code":true}]}],"person_identifier_entries":[{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202061057"],"render_values":[{"text":"202061057","href":null,"code":true}]}]},"links":{"outbound_url":"https://stax.strath.ac.uk/concern/theses/vm40xs237","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stax.strath.ac.uk/concern/theses/vm40xs237","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stax.strath.ac.uk/catalog/oai?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Astrathclyde%3Avm40xs237","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Chen, Yu, 1973 December 28-","Li, David Day-Uei"]},{"key":"dc:creator","label":"Author","values":["Wang, Quan"]},{"key":"dc:creator.authoridentifier","label":"Author Identifier","values":["202061057"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Strathclyde Institute of Pharmacy and Biomedical Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Strathclyde"]},{"key":"dc:relation.uri","label":"Dc Relation URI","values":["https://stax.strath.ac.uk/downloads/k3569510z"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral-pg"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["phd"]},{"key":"dc:type.uri","label":"Dc Type URI","values":["http://purl.org/coar/resource_type/c_db06"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights.uri","label":"Rights URI","values":["https://stax.strath.ac.uk/thesis_copyright_statement/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["T16929"]},{"key":"dc:identifier.doi","label":"DOI","values":["10.48730/jvk7-7f59"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stax.strath.ac.uk/concern/theses/vm40xs237"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This thesis was previously held under moratorium from 17th May 2024 until 17th may 2025.","Diffuse correlation spectroscopy (DCS) is a powerful tool for investigating microvascular dynamics in deep tissues. It has been used for non-invasive blood flow assessment at the bedside. This study first provides a thorough literature review on system setups (continuous-wave, frequency-domain, and time-domain) and derive corresponding theoretical models. I then present an innovative deep learning algorithm, DCS-NET, which is easy and robust to train, fast, and insensitive to measurement noise for data processing. The absolute blood flow index (BFi) at different depths with/without measurement noise was calculated, followed by a relative blood flow calculation. I then calculated the intrinsic sensitivity, and calculated BFi with varied optical properties and scalp/skull thicknesses finally. Compared with the semi-infinite, and three-layer fitting methods, I show that the DCS-NET is approximately 17,000 times faster than the traditional three-layer model and 32 times faster than the semi-infinite model, respectively. It provides increased inherent sensitivity to deep tissues compared to fitting methods. DCS-NET demonstrates remarkable noise resilience and is minimally affected by variations in ?a and ?s'. Additionally, we have shown that DCS-NET can extract relative blood flow index (rBFi) with a substantially lower error of 8.35%. In comparison, the semi-infinite and three-layer fitting models produce considerable errors in rBFi, amounting to 43.76% and 19.66%, respectively. Additionally, a DCS prototype is developed by integrating an advanced CMOS single-photon avalanche diode array, which employing a parallel light detection scheme, exhibits exceptional photon-counting throughput. The system tested on a milk phantom, showing SNR gain with the entire sensor is improved nearly 160-fold compared with a single pixel. An in vivo blood occlusion test was also performed. In conclusion, our system works well, and this research can offer peers effective guidance to embark on DCS research."]},{"key":"dc:description.abstract","label":"Abstract","values":["Diffuse correlation spectroscopy (DCS) is a powerful tool for investigating microvascular dynamics in deep tissues. It has been used for non-invasive blood flow assessment at the bedside. This study first provides a thorough literature review on system setups (continuous-wave, frequency-domain, and time-domain) and derive corresponding theoretical models. I then present an innovative deep learning algorithm, DCS-NET, which is easy and robust to train, fast, and insensitive to measurement noise for data processing. The absolute blood flow index (BFi) at different depths with/without measurement noise was calculated, followed by a relative blood flow calculation. I then calculated the intrinsic sensitivity, and calculated BFi with varied optical properties and scalp/skull thicknesses finally. Compared with the semi-infinite, and three-layer fitting methods, I show that the DCS-NET is approximately 17,000 times faster than the traditional three-layer model and 32 times faster than the semi-infinite model, respectively. It provides increased inherent sensitivity to deep tissues compared to fitting methods. DCS-NET demonstrates remarkable noise resilience and is minimally affected by variations in ?a and ?s'. Additionally, we have shown that DCS-NET can extract relative blood flow index (rBFi) with a substantially lower error of 8.35%. In comparison, the semi-infinite and three-layer fitting models produce considerable errors in rBFi, amounting to 43.76% and 19.66%, respectively. Additionally, a DCS prototype is developed by integrating an advanced CMOS single-photon avalanche diode array, which employing a parallel light detection scheme, exhibits exceptional photon-counting throughput. The system tested on a milk phantom, showing SNR gain with the entire sensor is improved nearly 160-fold compared with a single pixel. An in vivo blood occlusion test was also performed. In conclusion, our system works well, and this research can offer peers effective guidance to embark on DCS research."]},{"key":"dc:title","label":"Title","values":["Compact diffuse correlation spectroscopy systems"]}]}],"canonical_facts":{"dc:contributor.advisor":["Chen, Yu, 1973 December 28-","Li, David Day-Uei"],"dc:creator":["Wang, Quan"],"dc:creator.authoridentifier":["202061057"],"dc:date.issued":["2024"],"dc:description":["This thesis was previously held under moratorium from 17th May 2024 until 17th may 2025.","Diffuse correlation spectroscopy (DCS) is a powerful tool for investigating microvascular dynamics in deep tissues. It has been used for non-invasive blood flow assessment at the bedside. This study first provides a thorough literature review on system setups (continuous-wave, frequency-domain, and time-domain) and derive corresponding theoretical models. I then present an innovative deep learning algorithm, DCS-NET, which is easy and robust to train, fast, and insensitive to measurement noise for data processing. The absolute blood flow index (BFi) at different depths with/without measurement noise was calculated, followed by a relative blood flow calculation. I then calculated the intrinsic sensitivity, and calculated BFi with varied optical properties and scalp/skull thicknesses finally. Compared with the semi-infinite, and three-layer fitting methods, I show that the DCS-NET is approximately 17,000 times faster than the traditional three-layer model and 32 times faster than the semi-infinite model, respectively. It provides increased inherent sensitivity to deep tissues compared to fitting methods. DCS-NET demonstrates remarkable noise resilience and is minimally affected by variations in ?a and ?s'. Additionally, we have shown that DCS-NET can extract relative blood flow index (rBFi) with a substantially lower error of 8.35%. In comparison, the semi-infinite and three-layer fitting models produce considerable errors in rBFi, amounting to 43.76% and 19.66%, respectively. Additionally, a DCS prototype is developed by integrating an advanced CMOS single-photon avalanche diode array, which employing a parallel light detection scheme, exhibits exceptional photon-counting throughput. The system tested on a milk phantom, showing SNR gain with the entire sensor is improved nearly 160-fold compared with a single pixel. An in vivo blood occlusion test was also performed. In conclusion, our system works well, and this research can offer peers effective guidance to embark on DCS research."],"dc:description.abstract":["Diffuse correlation spectroscopy (DCS) is a powerful tool for investigating microvascular dynamics in deep tissues. It has been used for non-invasive blood flow assessment at the bedside. This study first provides a thorough literature review on system setups (continuous-wave, frequency-domain, and time-domain) and derive corresponding theoretical models. I then present an innovative deep learning algorithm, DCS-NET, which is easy and robust to train, fast, and insensitive to measurement noise for data processing. The absolute blood flow index (BFi) at different depths with/without measurement noise was calculated, followed by a relative blood flow calculation. I then calculated the intrinsic sensitivity, and calculated BFi with varied optical properties and scalp/skull thicknesses finally. Compared with the semi-infinite, and three-layer fitting methods, I show that the DCS-NET is approximately 17,000 times faster than the traditional three-layer model and 32 times faster than the semi-infinite model, respectively. It provides increased inherent sensitivity to deep tissues compared to fitting methods. DCS-NET demonstrates remarkable noise resilience and is minimally affected by variations in ?a and ?s'. Additionally, we have shown that DCS-NET can extract relative blood flow index (rBFi) with a substantially lower error of 8.35%. In comparison, the semi-infinite and three-layer fitting models produce considerable errors in rBFi, amounting to 43.76% and 19.66%, respectively. Additionally, a DCS prototype is developed by integrating an advanced CMOS single-photon avalanche diode array, which employing a parallel light detection scheme, exhibits exceptional photon-counting throughput. The system tested on a milk phantom, showing SNR gain with the entire sensor is improved nearly 160-fold compared with a single pixel. An in vivo blood occlusion test was also performed. In conclusion, our system works well, and this research can offer peers effective guidance to embark on DCS research."],"dc:identifier":["T16929"],"dc:identifier.doi":["10.48730/jvk7-7f59"],"dc:identifier.uri":["https://stax.strath.ac.uk/concern/theses/vm40xs237"],"dc:publisher.department":["Strathclyde Institute of Pharmacy and Biomedical Sciences"],"dc:publisher.institution":["University of Strathclyde"],"dc:relation.uri":["https://stax.strath.ac.uk/downloads/k3569510z"],"dc:rights.uri":["https://stax.strath.ac.uk/thesis_copyright_statement/"],"dc:title":["Compact diffuse correlation spectroscopy systems"],"dc:type.qualificationlevel":["doctoral-pg"],"dc:type.qualificationname":["phd"],"dc:type.uri":["http://purl.org/coar/resource_type/c_db06"]},"updated_at":"2026-11-19T16:21:03Z"}