{"id":{"repo_id":"texas-state","oai_identifier":"oai:digital.library.txst.edu:10877/3872"},"canonical_url":"https://search.ndltd.org/etd/texas-state/oai:digital.library.txst.edu:10877/3872","repository":{"repo_id":"texas-state","name":"Texas State University","base_url":"https://digital.library.txst.edu/server/oai/request"},"display":{"title":"Spectroscopic Measurements of Natural and Artificial Light Sources","abstract":"A twenty-night field investigation at the site where reportedly Marfa lights have most been observed was conducted. We made considerable progress in developing a technique to identify false positives and to estimate their distance based on the absorption of molecular oxygen at 762 nm band using the spectroscopic data alone (Stephan, Ghimire, Stapleton, &amp; Bunnell, 2009). Spectroscopic studies of a type of glow discharge supported by natural porous rock which covers relatively wide area of the rock, up to 2 cm in diameter, are presented. The rotational, translational and vibrational temperatures of the discharge are measured by comparing modeled optical emission spectra with spectroscopic measurements from the discharge. Finally, an absolute calibration technique for our spectroscopic system is presented.","abstract_html":"A twenty-night field investigation at the site where reportedly Marfa lights have most been observed was conducted. We made considerable progress in developing a technique to identify false positives and to estimate their distance based on the absorption of molecular oxygen at 762 nm band using the spectroscopic data alone (Stephan, Ghimire, Stapleton, &amp;amp; Bunnell, 2009). Spectroscopic studies of a type of glow discharge supported by natural porous rock which covers relatively wide area of the rock, up to 2 cm in diameter, are presented. The rotational, translational and vibrational temperatures of the discharge are measured by comparing modeled optical emission spectra with spectroscopic measurements from the discharge. Finally, an absolute calibration technique for our spectroscopic system is presented.","abstract_has_math":false,"creators":["Ghimire, Sagar"],"institution":"Texas State University-San Marcos","degree_name":"Master of Science","degree_level":"Masters","degree_discipline":"Industrial Technology","degree_department":"Engineering Technology","school":null,"contributors":[],"advisors":["Stephan, Karl D."],"committee_chairs":[],"committee_members":["Velasco, Eulogio","Geerts, Wilhelmus Johannes Maria Arnoldus"],"year":2010,"date_issued":"2010-08","date_published":"2010-08","updated_at":"2026-11-20T16:09:05Z","subjects":["Marfa lights","DC glow discharge","spectroscopic temperture measurements","absolute calibration","basalt","A band"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ghimire, S. (2010). Spectroscopic measurements of natural and artificial light sources. [Master's thesis, Texas State University-San Marcos]."],"render_values":[{"text":"Ghimire, S. (2010). Spectroscopic measurements of natural and artificial light sources. [Master's thesis, Texas State University-San Marcos].","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10877/3872","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10877/3872","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Atexas-state%3Aoai%3Adigital.library.txst.edu%3A10877%2F3872","prefix":"oai_dc"},"source_record":{"url":"https://digital.library.txst.edu/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adigital.library.txst.edu%3A10877%2F3872","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Stephan, Karl D."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Velasco, Eulogio","Geerts, Wilhelmus Johannes Maria Arnoldus"]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Technology"]},{"key":"dc:creator","label":"Author","values":["Ghimire, Sagar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-02-24T10:18:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-02-24T10:18:37Z"]},{"key":"dc:date.issued","label":"Date","values":["2010-08"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_department","label":"Department","values":["Engineering Technology"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial Technology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Texas State University-San Marcos"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Marfa lights","DC glow discharge","spectroscopic temperture measurements","absolute calibration","basalt","A band"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ghimire, S. (2010). Spectroscopic measurements of natural and artificial light sources. [Master's thesis, Texas State University-San Marcos]."]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10877/3872"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A twenty-night field investigation at the site where reportedly Marfa lights have most been observed was conducted. We made considerable progress in developing a technique to identify false positives and to estimate their distance based on the absorption of molecular oxygen at 762 nm band using the spectroscopic data alone (Stephan, Ghimire, Stapleton, &amp; Bunnell, 2009). Spectroscopic studies of a type of glow discharge supported by natural porous rock which covers relatively wide area of the rock, up to 2 cm in diameter, are presented. The rotational, translational and vibrational temperatures of the discharge are measured by comparing modeled optical emission spectra with spectroscopic measurements from the discharge. Finally, an absolute calibration technique for our spectroscopic system is presented."]},{"key":"dc:format","label":"Dc Format","values":["Text"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["41 pages"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["1 file (.pdf)"]},{"key":"dc:title","label":"Title","values":["Spectroscopic Measurements of Natural and Artificial Light Sources"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Stephan, Karl D."],"dc:contributor.committeemember":["Velasco, Eulogio","Geerts, Wilhelmus Johannes Maria Arnoldus"],"dc:contributor.department":["Engineering Technology"],"dc:creator":["Ghimire, Sagar"],"dc:date.accessioned":["2012-02-24T10:18:37Z"],"dc:date.available":["2012-02-24T10:18:37Z"],"dc:date.issued":["2010-08"],"dc:description.abstract":["A twenty-night field investigation at the site where reportedly Marfa lights have most been observed was conducted. We made considerable progress in developing a technique to identify false positives and to estimate their distance based on the absorption of molecular oxygen at 762 nm band using the spectroscopic data alone (Stephan, Ghimire, Stapleton, &amp; Bunnell, 2009). Spectroscopic studies of a type of glow discharge supported by natural porous rock which covers relatively wide area of the rock, up to 2 cm in diameter, are presented. The rotational, translational and vibrational temperatures of the discharge are measured by comparing modeled optical emission spectra with spectroscopic measurements from the discharge. Finally, an absolute calibration technique for our spectroscopic system is presented."],"dc:format":["Text"],"dc:format.extent":["41 pages"],"dc:format.medium":["1 file (.pdf)"],"dc:identifier.citation":["Ghimire, S. (2010). Spectroscopic measurements of natural and artificial light sources. [Master's thesis, Texas State University-San Marcos]."],"dc:identifier.uri":["https://hdl.handle.net/10877/3872"],"dc:language.iso":["en"],"dc:subject":["Marfa lights","DC glow discharge","spectroscopic temperture measurements","absolute calibration","basalt","A band"],"dc:title":["Spectroscopic Measurements of Natural and Artificial Light Sources"],"dc:type":["Thesis"],"others:access_status":["open.access"],"thesis:degree_department":["Engineering Technology"],"thesis:degree_discipline":["Industrial Technology"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Texas State University-San Marcos"]},"updated_at":"2026-11-20T16:09:05Z"}