{"id":{"repo_id":"trento","oai_identifier":"oai:iris.unitn.it:11572/369044"},"canonical_url":"https://search.ndltd.org/etd/trento/oai:iris.unitn.it:11572/369044","repository":{"repo_id":"trento","name":"Università degli Studi di Trento","base_url":"https://iris.unitn.it/oai/request"},"display":{"title":"Modeling, Design and Characterization of a Multi-Pixel Digital SiPM for PET Applications","abstract":"Positron Emission Tomography (PET) scanners provide functional three-dimensional images of the body that are extremely useful in cancer and brain research. The goal of this work is the modeling, design and characterization of a CMOS-based photodetector for PET. To this aim, first a model for the energy resolution and coincidence resolution time (CRT) for digital, SPAD-based detectors is developed. Then, a top-to-bottom detector architecture is proposed, containing an innovative in-pixel com-pression technique that allows for high fill-factor (FF) and efficient readout. At the top-level of the architecture, an integrated discriminator monitors the photon flux for incoming gamma events, enabling an event-based readout scheme. The first complete implementation of this archi-tecture is described, the SPADnet-I sensor, which is composed by an 8×16 pixel array, each of around 0.6 × 0.6 mm2 with 720 SPADs, resulting in a pixel FF of 42.6%. The sensor can obtain the discrete photon flux estimation at up to 100 Msamples/s, which are used by the discriminator and also output at real-time. The complete characterization of the sensor is presented, and the best sensor configuration was found to be at 84% of the SPADs enabled (disabled starting with the highest DCR one), with 2 V SPAD excess bias and 150 ns integration time. This configuration results in an energy resolution of 10.8% and a CRT of 288 ps, the latter which was obtained with a new, hardware-friendly time of arrival (ToA) estimation algorithm, also described in this thesis. Finally, the sensor model, validated by the experimental results, is used to predict the perfor-mance of possible modifications in the sensor, and some design improvements are suggested for a future implementation of the architecture.","abstract_html":"Positron Emission Tomography (PET) scanners provide functional three-dimensional images of the body that are extremely useful in cancer and brain research. The goal of this work is the modeling, design and characterization of a CMOS-based photodetector for PET. To this aim, first a model for the energy resolution and coincidence resolution time (CRT) for digital, SPAD-based detectors is developed. Then, a top-to-bottom detector architecture is proposed, containing an innovative in-pixel com-pression technique that allows for high fill-factor (FF) and efficient readout. At the top-level of the architecture, an integrated discriminator monitors the photon flux for incoming gamma events, enabling an event-based readout scheme. The first complete implementation of this archi-tecture is described, the SPADnet-I sensor, which is composed by an 8×16 pixel array, each of around 0.6 × 0.6 mm2 with 720 SPADs, resulting in a pixel FF of 42.6%. The sensor can obtain the discrete photon flux estimation at up to 100 Msamples/s, which are used by the discriminator and also output at real-time. The complete characterization of the sensor is presented, and the best sensor configuration was found to be at 84% of the SPADs enabled (disabled starting with the highest DCR one), with 2 V SPAD excess bias and 150 ns integration time. This configuration results in an energy resolution of 10.8% and a CRT of 288 ps, the latter which was obtained with a new, hardware-friendly time of arrival (ToA) estimation algorithm, also described in this thesis. Finally, the sensor model, validated by the experimental results, is used to predict the perfor-mance of possible modifications in the sensor, and some design improvements are suggested for a future implementation of the architecture.","abstract_has_math":false,"creators":["Huf Campos Braga, Leo"],"institution":"Università degli studi di Trento","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Stoppa, David"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-18T19:08:03Z","subjects":["Settore ING-INF/01 - Elettronica"],"languages":["eng"],"rights":["info:eu-repo/semantics/openAccess","license:Tutti i diritti riservati (All rights reserved)"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://hdl.handle.net/11572/369044"],"render_values":[{"text":"https://hdl.handle.net/11572/369044","href":"https://hdl.handle.net/11572/369044","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.15168/11572_369044","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.15168/11572_369044","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","access_status":"open","embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Atrento%3Aoai%3Airis.unitn.it%3A11572%2F369044","prefix":"oai_dc"},"source_record":{"url":"https://iris.unitn.it/oai/request?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Airis.unitn.it%3A11572%2F369044","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Huf Campos Braga, Leo","Stoppa, David"]},{"key":"dc:creator","label":"Author","values":["Huf Campos Braga, Leo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Università degli studi di Trento","place:TRENTO"]},{"key":"dc:relation","label":"Dc Relation","values":["firstpage:1","lastpage:123","numberofpages:123"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/doctoralThesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Settore ING-INF/01 - Elettronica"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess","license:Tutti i diritti riservati (All rights reserved)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://hdl.handle.net/11572/369044","http://dx.doi.org/10.15168/11572_369044","10.15168/11572_369044"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Positron Emission Tomography (PET) scanners provide functional three-dimensional images of the body that are extremely useful in cancer and brain research. The goal of this work is the modeling, design and characterization of a CMOS-based photodetector for PET. To this aim, first a model for the energy resolution and coincidence resolution time (CRT) for digital, SPAD-based detectors is developed. Then, a top-to-bottom detector architecture is proposed, containing an innovative in-pixel com-pression technique that allows for high fill-factor (FF) and efficient readout. At the top-level of the architecture, an integrated discriminator monitors the photon flux for incoming gamma events, enabling an event-based readout scheme. The first complete implementation of this archi-tecture is described, the SPADnet-I sensor, which is composed by an 8×16 pixel array, each of around 0.6 × 0.6 mm2 with 720 SPADs, resulting in a pixel FF of 42.6%. The sensor can obtain the discrete photon flux estimation at up to 100 Msamples/s, which are used by the discriminator and also output at real-time. The complete characterization of the sensor is presented, and the best sensor configuration was found to be at 84% of the SPADs enabled (disabled starting with the highest DCR one), with 2 V SPAD excess bias and 150 ns integration time. This configuration results in an energy resolution of 10.8% and a CRT of 288 ps, the latter which was obtained with a new, hardware-friendly time of arrival (ToA) estimation algorithm, also described in this thesis. Finally, the sensor model, validated by the experimental results, is used to predict the perfor-mance of possible modifications in the sensor, and some design improvements are suggested for a future implementation of the architecture."]},{"key":"dc:title","label":"Title","values":["Modeling, Design and Characterization of a Multi-Pixel Digital SiPM for PET Applications"]}]}],"canonical_facts":{"dc:contributor":["Huf Campos Braga, Leo","Stoppa, David"],"dc:creator":["Huf Campos Braga, Leo"],"dc:date":["2014"],"dc:description":["Positron Emission Tomography (PET) scanners provide functional three-dimensional images of the body that are extremely useful in cancer and brain research. The goal of this work is the modeling, design and characterization of a CMOS-based photodetector for PET. To this aim, first a model for the energy resolution and coincidence resolution time (CRT) for digital, SPAD-based detectors is developed. Then, a top-to-bottom detector architecture is proposed, containing an innovative in-pixel com-pression technique that allows for high fill-factor (FF) and efficient readout. At the top-level of the architecture, an integrated discriminator monitors the photon flux for incoming gamma events, enabling an event-based readout scheme. The first complete implementation of this archi-tecture is described, the SPADnet-I sensor, which is composed by an 8×16 pixel array, each of around 0.6 × 0.6 mm2 with 720 SPADs, resulting in a pixel FF of 42.6%. The sensor can obtain the discrete photon flux estimation at up to 100 Msamples/s, which are used by the discriminator and also output at real-time. The complete characterization of the sensor is presented, and the best sensor configuration was found to be at 84% of the SPADs enabled (disabled starting with the highest DCR one), with 2 V SPAD excess bias and 150 ns integration time. This configuration results in an energy resolution of 10.8% and a CRT of 288 ps, the latter which was obtained with a new, hardware-friendly time of arrival (ToA) estimation algorithm, also described in this thesis. Finally, the sensor model, validated by the experimental results, is used to predict the perfor-mance of possible modifications in the sensor, and some design improvements are suggested for a future implementation of the architecture."],"dc:identifier":["https://hdl.handle.net/11572/369044","http://dx.doi.org/10.15168/11572_369044","10.15168/11572_369044"],"dc:language":["eng"],"dc:publisher":["Università degli studi di Trento","place:TRENTO"],"dc:relation":["firstpage:1","lastpage:123","numberofpages:123"],"dc:rights":["info:eu-repo/semantics/openAccess","license:Tutti i diritti riservati (All rights reserved)"],"dc:subject":["Settore ING-INF/01 - Elettronica"],"dc:title":["Modeling, Design and Characterization of a Multi-Pixel Digital SiPM for PET Applications"],"dc:type":["info:eu-repo/semantics/doctoralThesis"]},"updated_at":"2026-11-18T19:08:03Z"}