{"id":{"repo_id":"uab","oai_identifier":"oai:digitalcommons.library.uab.edu:etd-collection-1348"},"canonical_url":"https://search.ndltd.org/etd/uab/oai:digitalcommons.library.uab.edu:etd-collection-1348","repository":{"repo_id":"uab","name":"University of Alabama Birmingham","base_url":"https://digitalcommons.library.uab.edu/do/oai/"},"display":{"title":"How Does Loss of Pulsatility Lead to Non-Surgical Bleeding in Continuous Flow Ventricular Assist Device Patterns","abstract":"The primary goal of this study is to evaluate the effect of diminished pulsatility associat-ed with Continuous Flow Ventricular Assist Devices (CF-VADs) on endothelial respons-es of pro-angiogenic/proinflammatory soluble factors and von Willebrand Factor (vWF). Non-surgical bleeding is one of the most common adverse events after CF-VAD implan-tation and is a major cause of morbidity in patients supported by CF-VAD therapy. Alt-hough the exact mechanisms remain unclear, development of arteriovenous malfor-mations (AVMs) and acquired von Willebrand factor syndrome (AVWS) are widely be-lieved to be major risk factors. Another challenge with the study of pulsatility is that pre-clinical studies to understand how loss of pulsatility contributes to non-surgical bleeding in CF-VAD recipients are very limited because of the lack of relevance and insufficient translation of results from available animal models. Therefore, in this project, we propose a comprehensive approach using an in-vitro Vessel-on-a-chip model – our Vascular Pulse Perfusion Model (VPPM), coupled with evaluation of blood samples from CF-VAD pa-tients, to study the effect of diminished pulsatility associated with CF-VAD on endotheli-al responses via pro-inflammatory/pro-angiogenic soluble factors and endothelial vWF.","abstract_html":"The primary goal of this study is to evaluate the effect of diminished pulsatility associat-ed with Continuous Flow Ventricular Assist Devices (CF-VADs) on endothelial respons-es of pro-angiogenic/proinflammatory soluble factors and von Willebrand Factor (vWF). Non-surgical bleeding is one of the most common adverse events after CF-VAD implan-tation and is a major cause of morbidity in patients supported by CF-VAD therapy. Alt-hough the exact mechanisms remain unclear, development of arteriovenous malfor-mations (AVMs) and acquired von Willebrand factor syndrome (AVWS) are widely be-lieved to be major risk factors. Another challenge with the study of pulsatility is that pre-clinical studies to understand how loss of pulsatility contributes to non-surgical bleeding in CF-VAD recipients are very limited because of the lack of relevance and insufficient translation of results from available animal models. Therefore, in this project, we propose a comprehensive approach using an in-vitro Vessel-on-a-chip model – our Vascular Pulse Perfusion Model (VPPM), coupled with evaluation of blood samples from CF-VAD pa-tients, to study the effect of diminished pulsatility associated with CF-VAD on endotheli-al responses via pro-inflammatory/pro-angiogenic soluble factors and endothelial vWF.","abstract_has_math":false,"creators":["Nguyen, Khahn Tu"],"institution":null,"degree_name":null,"degree_level":"Dissertation","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Palaniappan Sethu","Xiaoguang Liu","Gangjian Qin","Yuhua Song","Min Xie"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:26:51Z","subjects":["Continuous Flow VADs","diminished pulsatility","non-surgical bleeding","pro-inflammatory/pro-angiogenic soluble factors","von Willebrand factor","human aortic endothelial cells (HAECs)","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.library.uab.edu/etd-collection/355","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.library.uab.edu/etd-collection/355","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.library.uab.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.library.uab.edu%3Aetd-collection-1348","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Palaniappan Sethu","Xiaoguang Liu","Gangjian Qin","Yuhua Song","Min Xie"]},{"key":"dc:creator","label":"Author","values":["Nguyen, Khahn Tu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2022-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Continuous Flow VADs","diminished pulsatility","non-surgical bleeding","pro-inflammatory/pro-angiogenic soluble factors","von Willebrand factor","human aortic endothelial cells (HAECs)","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.library.uab.edu/etd-collection/355"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The primary goal of this study is to evaluate the effect of diminished pulsatility associat-ed with Continuous Flow Ventricular Assist Devices (CF-VADs) on endothelial respons-es of pro-angiogenic/proinflammatory soluble factors and von Willebrand Factor (vWF). Non-surgical bleeding is one of the most common adverse events after CF-VAD implan-tation and is a major cause of morbidity in patients supported by CF-VAD therapy. Alt-hough the exact mechanisms remain unclear, development of arteriovenous malfor-mations (AVMs) and acquired von Willebrand factor syndrome (AVWS) are widely be-lieved to be major risk factors. Another challenge with the study of pulsatility is that pre-clinical studies to understand how loss of pulsatility contributes to non-surgical bleeding in CF-VAD recipients are very limited because of the lack of relevance and insufficient translation of results from available animal models. Therefore, in this project, we propose a comprehensive approach using an in-vitro Vessel-on-a-chip model – our Vascular Pulse Perfusion Model (VPPM), coupled with evaluation of blood samples from CF-VAD pa-tients, to study the effect of diminished pulsatility associated with CF-VAD on endotheli-al responses via pro-inflammatory/pro-angiogenic soluble factors and endothelial vWF."]},{"key":"dc:description.note","label":"Dc Description Note","values":["etdadmin_upload_917583"]},{"key":"dc:title","label":"Title","values":["How Does Loss of Pulsatility Lead to Non-Surgical Bleeding in Continuous Flow Ventricular Assist Device Patterns"]}]}],"canonical_facts":{"dc:contributor":["Palaniappan Sethu","Xiaoguang Liu","Gangjian Qin","Yuhua Song","Min Xie"],"dc:creator":["Nguyen, Khahn Tu"],"dc:date.created":["2022-01-01T08:00:00Z"],"dc:description.abstract":["The primary goal of this study is to evaluate the effect of diminished pulsatility associat-ed with Continuous Flow Ventricular Assist Devices (CF-VADs) on endothelial respons-es of pro-angiogenic/proinflammatory soluble factors and von Willebrand Factor (vWF). Non-surgical bleeding is one of the most common adverse events after CF-VAD implan-tation and is a major cause of morbidity in patients supported by CF-VAD therapy. Alt-hough the exact mechanisms remain unclear, development of arteriovenous malfor-mations (AVMs) and acquired von Willebrand factor syndrome (AVWS) are widely be-lieved to be major risk factors. Another challenge with the study of pulsatility is that pre-clinical studies to understand how loss of pulsatility contributes to non-surgical bleeding in CF-VAD recipients are very limited because of the lack of relevance and insufficient translation of results from available animal models. Therefore, in this project, we propose a comprehensive approach using an in-vitro Vessel-on-a-chip model – our Vascular Pulse Perfusion Model (VPPM), coupled with evaluation of blood samples from CF-VAD pa-tients, to study the effect of diminished pulsatility associated with CF-VAD on endotheli-al responses via pro-inflammatory/pro-angiogenic soluble factors and endothelial vWF."],"dc:description.note":["etdadmin_upload_917583"],"dc:identifier":["https://digitalcommons.library.uab.edu/etd-collection/355"],"dc:subject":["Continuous Flow VADs","diminished pulsatility","non-surgical bleeding","pro-inflammatory/pro-angiogenic soluble factors","von Willebrand factor","human aortic endothelial cells (HAECs)","Engineering"],"dc:title":["How Does Loss of Pulsatility Lead to Non-Surgical Bleeding in Continuous Flow Ventricular Assist Device Patterns"],"thesis:degree_level":["Dissertation"]},"updated_at":"2026-11-19T09:26:51Z"}