{"id":{"repo_id":"uab","oai_identifier":"oai:digitalcommons.library.uab.edu:etd-collection-2677"},"canonical_url":"https://search.ndltd.org/etd/uab/oai:digitalcommons.library.uab.edu:etd-collection-2677","repository":{"repo_id":"uab","name":"University of Alabama Birmingham","base_url":"https://digitalcommons.library.uab.edu/do/oai/"},"display":{"title":"Capacity Of The 3M True Definition Scanner To Make Repeatable Impressions Depending On Placement Of Margins In Relation To Gingival Height.","abstract":"Purpose: To determine the precision and accuracy of the True Definition Scanner (3M) (TDS) to capture margins at different gingival heights. Materials and Methods: A typodont with soft gingiva and removable indexed Ivorine® teeth was used. Tooth #19 was prepared to fit an all-ceramic crown with a chamfer margin. Spacers placed beneath the prepared tooth elevated #19 in the typodont and controlled the tooth margin height relative to the gingival margin. The TDS was used as an intraoral scanner. A total of 50 scans were made with 5 groups of 10 scans each. In Group 1 (control) the prepared tooth margin was 1 mm supra- gingival, while in Group 2 the margin equi-gingival. In groups 3 through 5, the margin position was respectively 1, 2, or 3 mm infra-gingival. optical scans were generated following manufacturer’s recommended procedures. The STL files were processed using MeshLab software computer-aided analysis to trim to the tooth #19 margins producing a new output file. The new STL processed and surface area (SA) was measured using Netfabb software. All post-processing was performed by the same operator. Results: The measured SA of the scan groups was evaluated with one-way ANOVA and Tukey’s post-hoc test (p ≤ 0.05) and reveals a statistically significant difference between the groups. Post-hoc testing revealed no statistical difference between iii control group and equi-gingival group but did reveal statistical differences between each of the infra-gingival groups. Conclusion: Optical impressions using the TDS was determined to be reliable in producing precise impressions scans with supra-gingival and equi-gingival margins. However, as the position of the margin was located more infra-gingival, the scans become incomplete and result in loss of accuracy and precision compared to the control.","abstract_html":"Purpose: To determine the precision and accuracy of the True Definition Scanner (3M) (TDS) to capture margins at different gingival heights. Materials and Methods: A typodont with soft gingiva and removable indexed Ivorine® teeth was used. Tooth #19 was prepared to fit an all-ceramic crown with a chamfer margin. Spacers placed beneath the prepared tooth elevated #19 in the typodont and controlled the tooth margin height relative to the gingival margin. The TDS was used as an intraoral scanner. A total of 50 scans were made with 5 groups of 10 scans each. In Group 1 (control) the prepared tooth margin was 1 mm supra- gingival, while in Group 2 the margin equi-gingival. In groups 3 through 5, the margin position was respectively 1, 2, or 3 mm infra-gingival. optical scans were generated following manufacturer’s recommended procedures. The STL files were processed using MeshLab software computer-aided analysis to trim to the tooth #19 margins producing a new output file. The new STL processed and surface area (SA) was measured using Netfabb software. All post-processing was performed by the same operator. Results: The measured SA of the scan groups was evaluated with one-way ANOVA and Tukey’s post-hoc test (p ≤ 0.05) and reveals a statistically significant difference between the groups. Post-hoc testing revealed no statistical difference between iii control group and equi-gingival group but did reveal statistical differences between each of the infra-gingival groups. Conclusion: Optical impressions using the TDS was determined to be reliable in producing precise impressions scans with supra-gingival and equi-gingival margins. However, as the position of the margin was located more infra-gingival, the scans become incomplete and result in loss of accuracy and precision compared to the control.","abstract_has_math":false,"creators":["Galindo Ramirez, Ricardo Jose"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Daniel A Givan","James C Broome","Keith Kinderknecht","Nathaniel Lawson","Perng-Ru Liu"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:26:09Z","subjects":["Digital Impression","Intraoral Digital Scanner","Optical Impression","Surface Area","True Definition Scanner","Dentistry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.library.uab.edu/etd-collection/1685","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.library.uab.edu/etd-collection/1685","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.library.uab.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.library.uab.edu%3Aetd-collection-2677","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Daniel A Givan","James C Broome","Keith Kinderknecht","Nathaniel Lawson","Perng-Ru Liu"]},{"key":"dc:creator","label":"Author","values":["Galindo Ramirez, Ricardo Jose"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Digital Impression","Intraoral Digital Scanner","Optical Impression","Surface Area","True Definition Scanner","Dentistry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.library.uab.edu/etd-collection/1685"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: To determine the precision and accuracy of the True Definition Scanner (3M) (TDS) to capture margins at different gingival heights. Materials and Methods: A typodont with soft gingiva and removable indexed Ivorine® teeth was used. Tooth #19 was prepared to fit an all-ceramic crown with a chamfer margin. Spacers placed beneath the prepared tooth elevated #19 in the typodont and controlled the tooth margin height relative to the gingival margin. The TDS was used as an intraoral scanner. A total of 50 scans were made with 5 groups of 10 scans each. In Group 1 (control) the prepared tooth margin was 1 mm supra- gingival, while in Group 2 the margin equi-gingival. In groups 3 through 5, the margin position was respectively 1, 2, or 3 mm infra-gingival. optical scans were generated following manufacturer’s recommended procedures. The STL files were processed using MeshLab software computer-aided analysis to trim to the tooth #19 margins producing a new output file. The new STL processed and surface area (SA) was measured using Netfabb software. All post-processing was performed by the same operator. Results: The measured SA of the scan groups was evaluated with one-way ANOVA and Tukey’s post-hoc test (p ≤ 0.05) and reveals a statistically significant difference between the groups. Post-hoc testing revealed no statistical difference between iii control group and equi-gingival group but did reveal statistical differences between each of the infra-gingival groups. Conclusion: Optical impressions using the TDS was determined to be reliable in producing precise impressions scans with supra-gingival and equi-gingival margins. However, as the position of the margin was located more infra-gingival, the scans become incomplete and result in loss of accuracy and precision compared to the control."]},{"key":"dc:description.note","label":"Dc Description Note","values":["etdadmin_upload_451021"]},{"key":"dc:title","label":"Title","values":["Capacity Of The 3M True Definition Scanner To Make Repeatable Impressions Depending On Placement Of Margins In Relation To Gingival Height."]}]}],"canonical_facts":{"dc:contributor":["Daniel A Givan","James C Broome","Keith Kinderknecht","Nathaniel Lawson","Perng-Ru Liu"],"dc:creator":["Galindo Ramirez, Ricardo Jose"],"dc:date.created":["2016-01-01T08:00:00Z"],"dc:description.abstract":["Purpose: To determine the precision and accuracy of the True Definition Scanner (3M) (TDS) to capture margins at different gingival heights. Materials and Methods: A typodont with soft gingiva and removable indexed Ivorine® teeth was used. Tooth #19 was prepared to fit an all-ceramic crown with a chamfer margin. Spacers placed beneath the prepared tooth elevated #19 in the typodont and controlled the tooth margin height relative to the gingival margin. The TDS was used as an intraoral scanner. A total of 50 scans were made with 5 groups of 10 scans each. In Group 1 (control) the prepared tooth margin was 1 mm supra- gingival, while in Group 2 the margin equi-gingival. In groups 3 through 5, the margin position was respectively 1, 2, or 3 mm infra-gingival. optical scans were generated following manufacturer’s recommended procedures. The STL files were processed using MeshLab software computer-aided analysis to trim to the tooth #19 margins producing a new output file. The new STL processed and surface area (SA) was measured using Netfabb software. All post-processing was performed by the same operator. Results: The measured SA of the scan groups was evaluated with one-way ANOVA and Tukey’s post-hoc test (p ≤ 0.05) and reveals a statistically significant difference between the groups. Post-hoc testing revealed no statistical difference between iii control group and equi-gingival group but did reveal statistical differences between each of the infra-gingival groups. Conclusion: Optical impressions using the TDS was determined to be reliable in producing precise impressions scans with supra-gingival and equi-gingival margins. However, as the position of the margin was located more infra-gingival, the scans become incomplete and result in loss of accuracy and precision compared to the control."],"dc:description.note":["etdadmin_upload_451021"],"dc:identifier":["https://digitalcommons.library.uab.edu/etd-collection/1685"],"dc:subject":["Digital Impression","Intraoral Digital Scanner","Optical Impression","Surface Area","True Definition Scanner","Dentistry"],"dc:title":["Capacity Of The 3M True Definition Scanner To Make Repeatable Impressions Depending On Placement Of Margins In Relation To Gingival Height."],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-19T09:26:09Z"}