{"id":{"repo_id":"uab","oai_identifier":"oai:digitalcommons.library.uab.edu:etd-collection-3163"},"canonical_url":"https://search.ndltd.org/etd/uab/oai:digitalcommons.library.uab.edu:etd-collection-3163","repository":{"repo_id":"uab","name":"University of Alabama Birmingham","base_url":"https://digitalcommons.library.uab.edu/do/oai/"},"display":{"title":"Histomorphometry and Quantitative Analysis of Longer-Term Implant Interfaces","abstract":"Objective: This investigation was to evaluate (>10 year) bone response around custom (HA plasma coated) dental implants and HA particulate. Materials and Methods: Three individual post mortem mandibular COI Implants with surrounding bone were processed at six transverse locations to obtain non-decalcified ground sections (20-80µm)(n=36) and stained initially with methylene blue/basic fuchsin. Slides were evaluated to select (n= 8) slides for regions of interest along the perimeter of the implant, using optical microscopy (Olympus BX51 microscope) with a Retiga EXi color digital camera (Olympus, Center Valley, PA) and Bioquant VR software (R&M Biometrics, Nashville, TN) at an original magnification from 1-100X and examining 1 mm around implant component. Additional non-decalcified sections were processed (n=5), TRAP stained and examined, focused on osteoclast cells that were identified by TRAP staining. Histomorphometric analyses showed peri-implant area coverage of residual CaP coating at 46.6% for all specimens. TRAP staining showed the most osteoclastic activity along CaP surfaces, followed by the CaP implant-coating and the residual alloy implant to bone contacting regions. Due to a small sample size statistical analyses were not utilized. Conclusions: Analyses of bone-implant interfaces and osteoclasts from non-decalcified sections of three patients (>10 year) post mortem custom dental implants showed very different interactions where CaP implant-coatings were being replaced, particulate CaP were partially replaced, and osseous integration along all types of implant surfaces was maintained.","abstract_html":"Objective: This investigation was to evaluate (&gt;10 year) bone response around custom (HA plasma coated) dental implants and HA particulate. Materials and Methods: Three individual post mortem mandibular COI Implants with surrounding bone were processed at six transverse locations to obtain non-decalcified ground sections (20-80µm)(n=36) and stained initially with methylene blue/basic fuchsin. Slides were evaluated to select (n= 8) slides for regions of interest along the perimeter of the implant, using optical microscopy (Olympus BX51 microscope) with a Retiga EXi color digital camera (Olympus, Center Valley, PA) and Bioquant VR software (R&amp;M Biometrics, Nashville, TN) at an original magnification from 1-100X and examining 1 mm around implant component. Additional non-decalcified sections were processed (n=5), TRAP stained and examined, focused on osteoclast cells that were identified by TRAP staining. Histomorphometric analyses showed peri-implant area coverage of residual CaP coating at 46.6% for all specimens. TRAP staining showed the most osteoclastic activity along CaP surfaces, followed by the CaP implant-coating and the residual alloy implant to bone contacting regions. Due to a small sample size statistical analyses were not utilized. Conclusions: Analyses of bone-implant interfaces and osteoclasts from non-decalcified sections of three patients (&gt;10 year) post mortem custom dental implants showed very different interactions where CaP implant-coatings were being replaced, particulate CaP were partially replaced, and osseous integration along all types of implant surfaces was maintained.","abstract_has_math":false,"creators":["Kojic, Dave Darko"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Jack Lemons","John O Burgess","Patricia Devilliers","Amjad Javed","Lance C Ramp"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:25:19Z","subjects":["bone","Dental implant","hydroxyapatite","osteoclasts","TRAP staining","Dentistry"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.library.uab.edu/etd-collection/2171","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.library.uab.edu/etd-collection/2171","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.library.uab.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.library.uab.edu%3Aetd-collection-3163","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jack Lemons","John O Burgess","Patricia Devilliers","Amjad Javed","Lance C Ramp"]},{"key":"dc:creator","label":"Author","values":["Kojic, Dave Darko"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2012-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bone","Dental implant","hydroxyapatite","osteoclasts","TRAP staining","Dentistry"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.library.uab.edu/etd-collection/2171"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objective: This investigation was to evaluate (>10 year) bone response around custom (HA plasma coated) dental implants and HA particulate. Materials and Methods: Three individual post mortem mandibular COI Implants with surrounding bone were processed at six transverse locations to obtain non-decalcified ground sections (20-80µm)(n=36) and stained initially with methylene blue/basic fuchsin. Slides were evaluated to select (n= 8) slides for regions of interest along the perimeter of the implant, using optical microscopy (Olympus BX51 microscope) with a Retiga EXi color digital camera (Olympus, Center Valley, PA) and Bioquant VR software (R&M Biometrics, Nashville, TN) at an original magnification from 1-100X and examining 1 mm around implant component. Additional non-decalcified sections were processed (n=5), TRAP stained and examined, focused on osteoclast cells that were identified by TRAP staining. Histomorphometric analyses showed peri-implant area coverage of residual CaP coating at 46.6% for all specimens. TRAP staining showed the most osteoclastic activity along CaP surfaces, followed by the CaP implant-coating and the residual alloy implant to bone contacting regions. Due to a small sample size statistical analyses were not utilized. Conclusions: Analyses of bone-implant interfaces and osteoclasts from non-decalcified sections of three patients (>10 year) post mortem custom dental implants showed very different interactions where CaP implant-coatings were being replaced, particulate CaP were partially replaced, and osseous integration along all types of implant surfaces was maintained."]},{"key":"dc:description.note","label":"Dc Description Note","values":["etdadmin_upload_164706"]},{"key":"dc:title","label":"Title","values":["Histomorphometry and Quantitative Analysis of Longer-Term Implant Interfaces"]}]}],"canonical_facts":{"dc:contributor":["Jack Lemons","John O Burgess","Patricia Devilliers","Amjad Javed","Lance C Ramp"],"dc:creator":["Kojic, Dave Darko"],"dc:date.created":["2012-01-01T08:00:00Z"],"dc:description.abstract":["Objective: This investigation was to evaluate (>10 year) bone response around custom (HA plasma coated) dental implants and HA particulate. Materials and Methods: Three individual post mortem mandibular COI Implants with surrounding bone were processed at six transverse locations to obtain non-decalcified ground sections (20-80µm)(n=36) and stained initially with methylene blue/basic fuchsin. Slides were evaluated to select (n= 8) slides for regions of interest along the perimeter of the implant, using optical microscopy (Olympus BX51 microscope) with a Retiga EXi color digital camera (Olympus, Center Valley, PA) and Bioquant VR software (R&M Biometrics, Nashville, TN) at an original magnification from 1-100X and examining 1 mm around implant component. Additional non-decalcified sections were processed (n=5), TRAP stained and examined, focused on osteoclast cells that were identified by TRAP staining. Histomorphometric analyses showed peri-implant area coverage of residual CaP coating at 46.6% for all specimens. TRAP staining showed the most osteoclastic activity along CaP surfaces, followed by the CaP implant-coating and the residual alloy implant to bone contacting regions. Due to a small sample size statistical analyses were not utilized. Conclusions: Analyses of bone-implant interfaces and osteoclasts from non-decalcified sections of three patients (>10 year) post mortem custom dental implants showed very different interactions where CaP implant-coatings were being replaced, particulate CaP were partially replaced, and osseous integration along all types of implant surfaces was maintained."],"dc:description.note":["etdadmin_upload_164706"],"dc:identifier":["https://digitalcommons.library.uab.edu/etd-collection/2171"],"dc:subject":["bone","Dental implant","hydroxyapatite","osteoclasts","TRAP staining","Dentistry"],"dc:title":["Histomorphometry and Quantitative Analysis of Longer-Term Implant Interfaces"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-19T09:25:19Z"}