{"id":{"repo_id":"uab","oai_identifier":"oai:digitalcommons.library.uab.edu:etd-collection-3360"},"canonical_url":"https://search.ndltd.org/etd/uab/oai:digitalcommons.library.uab.edu:etd-collection-3360","repository":{"repo_id":"uab","name":"University of Alabama Birmingham","base_url":"https://digitalcommons.library.uab.edu/do/oai/"},"display":{"title":"Volumetric Contrast-Enhanced Ultrasound Imaging of Vascular Perfusion in Renal Tissue","abstract":"This research examines the ability of volumetric contrast-enhanced ultrasound (VCEUS) imaging to quantify kidney blood flow, with the potential to monitor changes in renal perfusion following acute kidney injury (AKI). Ultrasound (US) imaging of microbubble contrast agents allows for increased imaging isolation of the vasculature, creating a non-toxic approach to visualizing blood flow. VCEUS utilizes a series of planar ultrasound acquisitions that can be collected in real time to survey the vascularity of a volumetric region-of-interest. Through post-processing methods it is possible to quantify perfusion parameters such as peak intensity (IPK), time-to-peak intensity (TPK), wash-in rate (WIR), and area-under-curve (AUC). We hypothesize that VCEUS will be a valuable addition to current techniques to track changes in kidney perfusion for both healthy and injured kidney. AKI involves the development of ischemia and decreased glomerular filtration rate in kidneys following some inducing injury, and is in need of a non-toxic, noninvasive imaging approach to monitor patient response to treatment. Current methods of detecting and determining the extent of AKI involve the detection of certain biomarkers in the blood serum and urine, such as creatinine. However, these methods lack the ideal specificity and sensitivity for AKI detection and monitoring. For this thesis project, custom US image processing software was developed with the purpose of deriving the described perfusion parameters, which will give us the necessary information to assess the kidney activity. Studies were initially performed investigating perfusion parameters in a vascular flow phantom, confirming the ability of the software to quantify VCEUS. Investigation of healthy rat kidneys further optimized data acquisition and image processing techniques. Investigation of rat kidneys that underwent ischemia-reperfusion injury allowed collection of pilot information to validate the ability of VCEUS imaging to monitor reperfusion response after AKI. Comparison with controls and current methods, such as creatinine, allow for confirmation of imaging analysis. These preclinical explorations give a complete study for VCEUS imaging of kidney blood flow, which gives the basis for further investigation into this field. The proposed methods in conjunction with currently available techniques have the potential for providing a more accurate representation of the disease state.","abstract_html":"This research examines the ability of volumetric contrast-enhanced ultrasound (VCEUS) imaging to quantify kidney blood flow, with the potential to monitor changes in renal perfusion following acute kidney injury (AKI). Ultrasound (US) imaging of microbubble contrast agents allows for increased imaging isolation of the vasculature, creating a non-toxic approach to visualizing blood flow. VCEUS utilizes a series of planar ultrasound acquisitions that can be collected in real time to survey the vascularity of a volumetric region-of-interest. Through post-processing methods it is possible to quantify perfusion parameters such as peak intensity (IPK), time-to-peak intensity (TPK), wash-in rate (WIR), and area-under-curve (AUC). We hypothesize that VCEUS will be a valuable addition to current techniques to track changes in kidney perfusion for both healthy and injured kidney. AKI involves the development of ischemia and decreased glomerular filtration rate in kidneys following some inducing injury, and is in need of a non-toxic, noninvasive imaging approach to monitor patient response to treatment. Current methods of detecting and determining the extent of AKI involve the detection of certain biomarkers in the blood serum and urine, such as creatinine. However, these methods lack the ideal specificity and sensitivity for AKI detection and monitoring. For this thesis project, custom US image processing software was developed with the purpose of deriving the described perfusion parameters, which will give us the necessary information to assess the kidney activity. Studies were initially performed investigating perfusion parameters in a vascular flow phantom, confirming the ability of the software to quantify VCEUS. Investigation of healthy rat kidneys further optimized data acquisition and image processing techniques. Investigation of rat kidneys that underwent ischemia-reperfusion injury allowed collection of pilot information to validate the ability of VCEUS imaging to monitor reperfusion response after AKI. Comparison with controls and current methods, such as creatinine, allow for confirmation of imaging analysis. These preclinical explorations give a complete study for VCEUS imaging of kidney blood flow, which gives the basis for further investigation into this field. The proposed methods in conjunction with currently available techniques have the potential for providing a more accurate representation of the disease state.","abstract_has_math":false,"creators":["Mahoney, Marshall Joseph"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Kenneth Hoyt","Joel Berry","Kurt Zinn"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:25:19Z","subjects":["acute kidney injury","ischemia-reperfusion","microbubble contrast agent","volumetric contrast enhanced ultrasound","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.library.uab.edu/etd-collection/2368","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.library.uab.edu/etd-collection/2368","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.library.uab.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.library.uab.edu%3Aetd-collection-3360","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kenneth Hoyt","Joel Berry","Kurt Zinn"]},{"key":"dc:creator","label":"Author","values":["Mahoney, Marshall Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2013-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["acute kidney injury","ischemia-reperfusion","microbubble contrast agent","volumetric contrast enhanced ultrasound","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.library.uab.edu/etd-collection/2368"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research examines the ability of volumetric contrast-enhanced ultrasound (VCEUS) imaging to quantify kidney blood flow, with the potential to monitor changes in renal perfusion following acute kidney injury (AKI). Ultrasound (US) imaging of microbubble contrast agents allows for increased imaging isolation of the vasculature, creating a non-toxic approach to visualizing blood flow. VCEUS utilizes a series of planar ultrasound acquisitions that can be collected in real time to survey the vascularity of a volumetric region-of-interest. Through post-processing methods it is possible to quantify perfusion parameters such as peak intensity (IPK), time-to-peak intensity (TPK), wash-in rate (WIR), and area-under-curve (AUC). We hypothesize that VCEUS will be a valuable addition to current techniques to track changes in kidney perfusion for both healthy and injured kidney. AKI involves the development of ischemia and decreased glomerular filtration rate in kidneys following some inducing injury, and is in need of a non-toxic, noninvasive imaging approach to monitor patient response to treatment. Current methods of detecting and determining the extent of AKI involve the detection of certain biomarkers in the blood serum and urine, such as creatinine. However, these methods lack the ideal specificity and sensitivity for AKI detection and monitoring. For this thesis project, custom US image processing software was developed with the purpose of deriving the described perfusion parameters, which will give us the necessary information to assess the kidney activity. Studies were initially performed investigating perfusion parameters in a vascular flow phantom, confirming the ability of the software to quantify VCEUS. Investigation of healthy rat kidneys further optimized data acquisition and image processing techniques. Investigation of rat kidneys that underwent ischemia-reperfusion injury allowed collection of pilot information to validate the ability of VCEUS imaging to monitor reperfusion response after AKI. Comparison with controls and current methods, such as creatinine, allow for confirmation of imaging analysis. These preclinical explorations give a complete study for VCEUS imaging of kidney blood flow, which gives the basis for further investigation into this field. The proposed methods in conjunction with currently available techniques have the potential for providing a more accurate representation of the disease state."]},{"key":"dc:description.note","label":"Dc Description Note","values":["etdadmin_upload_229664"]},{"key":"dc:title","label":"Title","values":["Volumetric Contrast-Enhanced Ultrasound Imaging of Vascular Perfusion in Renal Tissue"]}]}],"canonical_facts":{"dc:contributor":["Kenneth Hoyt","Joel Berry","Kurt Zinn"],"dc:creator":["Mahoney, Marshall Joseph"],"dc:date.created":["2013-01-01T08:00:00Z"],"dc:description.abstract":["This research examines the ability of volumetric contrast-enhanced ultrasound (VCEUS) imaging to quantify kidney blood flow, with the potential to monitor changes in renal perfusion following acute kidney injury (AKI). Ultrasound (US) imaging of microbubble contrast agents allows for increased imaging isolation of the vasculature, creating a non-toxic approach to visualizing blood flow. VCEUS utilizes a series of planar ultrasound acquisitions that can be collected in real time to survey the vascularity of a volumetric region-of-interest. Through post-processing methods it is possible to quantify perfusion parameters such as peak intensity (IPK), time-to-peak intensity (TPK), wash-in rate (WIR), and area-under-curve (AUC). We hypothesize that VCEUS will be a valuable addition to current techniques to track changes in kidney perfusion for both healthy and injured kidney. AKI involves the development of ischemia and decreased glomerular filtration rate in kidneys following some inducing injury, and is in need of a non-toxic, noninvasive imaging approach to monitor patient response to treatment. Current methods of detecting and determining the extent of AKI involve the detection of certain biomarkers in the blood serum and urine, such as creatinine. However, these methods lack the ideal specificity and sensitivity for AKI detection and monitoring. For this thesis project, custom US image processing software was developed with the purpose of deriving the described perfusion parameters, which will give us the necessary information to assess the kidney activity. Studies were initially performed investigating perfusion parameters in a vascular flow phantom, confirming the ability of the software to quantify VCEUS. Investigation of healthy rat kidneys further optimized data acquisition and image processing techniques. Investigation of rat kidneys that underwent ischemia-reperfusion injury allowed collection of pilot information to validate the ability of VCEUS imaging to monitor reperfusion response after AKI. Comparison with controls and current methods, such as creatinine, allow for confirmation of imaging analysis. These preclinical explorations give a complete study for VCEUS imaging of kidney blood flow, which gives the basis for further investigation into this field. The proposed methods in conjunction with currently available techniques have the potential for providing a more accurate representation of the disease state."],"dc:description.note":["etdadmin_upload_229664"],"dc:identifier":["https://digitalcommons.library.uab.edu/etd-collection/2368"],"dc:subject":["acute kidney injury","ischemia-reperfusion","microbubble contrast agent","volumetric contrast enhanced ultrasound","Engineering"],"dc:title":["Volumetric Contrast-Enhanced Ultrasound Imaging of Vascular Perfusion in Renal Tissue"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-19T09:25:19Z"}