{"id":{"repo_id":"uab","oai_identifier":"oai:digitalcommons.library.uab.edu:etd-collection-3384"},"canonical_url":"https://search.ndltd.org/etd/uab/oai:digitalcommons.library.uab.edu:etd-collection-3384","repository":{"repo_id":"uab","name":"University of Alabama Birmingham","base_url":"https://digitalcommons.library.uab.edu/do/oai/"},"display":{"title":"In Vitro Prevascularization of 3D Tissue Constructs","abstract":"There is a need for more effective therapies to combat breast cancer. One reason for the inefficiency of therapeutics is that testing technologies currently employed in drug discovery and development are not reliable when transitioning drugs into human clinical trials. To supplement the currently used in vitro cell culture studies and in vivo animal studies, an in vitro three-dimensional breast tumor system has been suggested with integration of human cells, hydrogel biomaterials, 3D architecture, and endothelialized microchannels. Therefore, the objective of the thesis project, as an initial step in fabrication of the supplemental system for drug testing, is to fabricate and characterize a tissue volume with pre-fabricated EC-lined microchannels representing the vasculature of a breast tumor. It is hypothesized that an in vitro three-dimensional microphysiologic system can be constructed with extracellular matrix and flow-through microchannels that will support a confluent endothelial layer. Results have shown that fabricated three-dimensional microenvironments, composed of extracellular matrix components, had a matrix elasticity similar to that of normal mammary tissue. An iterative design process of bioreactor fabrication led to a bioreactor that could contain a three-dimensional scaffold with a mean wall shear stress in the range of 0-5 dyne/cm2 inside the microchannels. In addition, the bioreactor system and endothelialization protocol facilitated the localization and attachment of endothelial cells inside the prefabricated microchannels. Future work will include further characterization of endothelial cell morphology and function and assessment of barrier function and permeability of the engineered endothelium. Continuation of this proof-of-concept project will lead to the formation of a confluent endothelial cell monolayer, which may be used to perfuse the three-dimensional tissue-engineered scaffold, to act as a dissemination route for tumor cells, or to act as a route for therapeutics to the tumor site.","abstract_html":"There is a need for more effective therapies to combat breast cancer. One reason for the inefficiency of therapeutics is that testing technologies currently employed in drug discovery and development are not reliable when transitioning drugs into human clinical trials. To supplement the currently used in vitro cell culture studies and in vivo animal studies, an in vitro three-dimensional breast tumor system has been suggested with integration of human cells, hydrogel biomaterials, 3D architecture, and endothelialized microchannels. Therefore, the objective of the thesis project, as an initial step in fabrication of the supplemental system for drug testing, is to fabricate and characterize a tissue volume with pre-fabricated EC-lined microchannels representing the vasculature of a breast tumor. It is hypothesized that an in vitro three-dimensional microphysiologic system can be constructed with extracellular matrix and flow-through microchannels that will support a confluent endothelial layer. Results have shown that fabricated three-dimensional microenvironments, composed of extracellular matrix components, had a matrix elasticity similar to that of normal mammary tissue. An iterative design process of bioreactor fabrication led to a bioreactor that could contain a three-dimensional scaffold with a mean wall shear stress in the range of 0-5 dyne/cm2 inside the microchannels. In addition, the bioreactor system and endothelialization protocol facilitated the localization and attachment of endothelial cells inside the prefabricated microchannels. Future work will include further characterization of endothelial cell morphology and function and assessment of barrier function and permeability of the engineered endothelium. Continuation of this proof-of-concept project will lead to the formation of a confluent endothelial cell monolayer, which may be used to perfuse the three-dimensional tissue-engineered scaffold, to act as a dissemination route for tumor cells, or to act as a route for therapeutics to the tumor site.","abstract_has_math":false,"creators":["Marshall, Lauren"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Joel L Berry","Andra R Frost","Andrew Penman","Joanne Murphy-Ullrich","Timothy M Wick"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:24:20Z","subjects":["3D tumor architecture","breast cancer","microvessels","perfusion flow bioreactor","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.library.uab.edu/etd-collection/2392","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.library.uab.edu/etd-collection/2392","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.library.uab.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.library.uab.edu%3Aetd-collection-3384","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Joel L Berry","Andra R Frost","Andrew Penman","Joanne Murphy-Ullrich","Timothy M Wick"]},{"key":"dc:creator","label":"Author","values":["Marshall, Lauren"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2013-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["3D tumor architecture","breast cancer","microvessels","perfusion flow bioreactor","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.library.uab.edu/etd-collection/2392"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["There is a need for more effective therapies to combat breast cancer. One reason for the inefficiency of therapeutics is that testing technologies currently employed in drug discovery and development are not reliable when transitioning drugs into human clinical trials. To supplement the currently used in vitro cell culture studies and in vivo animal studies, an in vitro three-dimensional breast tumor system has been suggested with integration of human cells, hydrogel biomaterials, 3D architecture, and endothelialized microchannels. Therefore, the objective of the thesis project, as an initial step in fabrication of the supplemental system for drug testing, is to fabricate and characterize a tissue volume with pre-fabricated EC-lined microchannels representing the vasculature of a breast tumor. It is hypothesized that an in vitro three-dimensional microphysiologic system can be constructed with extracellular matrix and flow-through microchannels that will support a confluent endothelial layer. Results have shown that fabricated three-dimensional microenvironments, composed of extracellular matrix components, had a matrix elasticity similar to that of normal mammary tissue. An iterative design process of bioreactor fabrication led to a bioreactor that could contain a three-dimensional scaffold with a mean wall shear stress in the range of 0-5 dyne/cm2 inside the microchannels. In addition, the bioreactor system and endothelialization protocol facilitated the localization and attachment of endothelial cells inside the prefabricated microchannels. Future work will include further characterization of endothelial cell morphology and function and assessment of barrier function and permeability of the engineered endothelium. Continuation of this proof-of-concept project will lead to the formation of a confluent endothelial cell monolayer, which may be used to perfuse the three-dimensional tissue-engineered scaffold, to act as a dissemination route for tumor cells, or to act as a route for therapeutics to the tumor site."]},{"key":"dc:description.note","label":"Dc Description Note","values":["etdadmin_upload_246754"]},{"key":"dc:title","label":"Title","values":["In Vitro Prevascularization of 3D Tissue Constructs"]}]}],"canonical_facts":{"dc:contributor":["Joel L Berry","Andra R Frost","Andrew Penman","Joanne Murphy-Ullrich","Timothy M Wick"],"dc:creator":["Marshall, Lauren"],"dc:date.created":["2013-01-01T08:00:00Z"],"dc:description.abstract":["There is a need for more effective therapies to combat breast cancer. One reason for the inefficiency of therapeutics is that testing technologies currently employed in drug discovery and development are not reliable when transitioning drugs into human clinical trials. To supplement the currently used in vitro cell culture studies and in vivo animal studies, an in vitro three-dimensional breast tumor system has been suggested with integration of human cells, hydrogel biomaterials, 3D architecture, and endothelialized microchannels. Therefore, the objective of the thesis project, as an initial step in fabrication of the supplemental system for drug testing, is to fabricate and characterize a tissue volume with pre-fabricated EC-lined microchannels representing the vasculature of a breast tumor. It is hypothesized that an in vitro three-dimensional microphysiologic system can be constructed with extracellular matrix and flow-through microchannels that will support a confluent endothelial layer. Results have shown that fabricated three-dimensional microenvironments, composed of extracellular matrix components, had a matrix elasticity similar to that of normal mammary tissue. An iterative design process of bioreactor fabrication led to a bioreactor that could contain a three-dimensional scaffold with a mean wall shear stress in the range of 0-5 dyne/cm2 inside the microchannels. In addition, the bioreactor system and endothelialization protocol facilitated the localization and attachment of endothelial cells inside the prefabricated microchannels. Future work will include further characterization of endothelial cell morphology and function and assessment of barrier function and permeability of the engineered endothelium. Continuation of this proof-of-concept project will lead to the formation of a confluent endothelial cell monolayer, which may be used to perfuse the three-dimensional tissue-engineered scaffold, to act as a dissemination route for tumor cells, or to act as a route for therapeutics to the tumor site."],"dc:description.note":["etdadmin_upload_246754"],"dc:identifier":["https://digitalcommons.library.uab.edu/etd-collection/2392"],"dc:subject":["3D tumor architecture","breast cancer","microvessels","perfusion flow bioreactor","Engineering"],"dc:title":["In Vitro Prevascularization of 3D Tissue Constructs"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-19T09:24:20Z"}