{"id":{"repo_id":"uab","oai_identifier":"oai:digitalcommons.library.uab.edu:etd-collection-3627"},"canonical_url":"https://search.ndltd.org/etd/uab/oai:digitalcommons.library.uab.edu:etd-collection-3627","repository":{"repo_id":"uab","name":"University of Alabama Birmingham","base_url":"https://digitalcommons.library.uab.edu/do/oai/"},"display":{"title":"Thermal-Mechanical Precast Concrete Panels Comprised Of Hybrid-Polymerized Sandwich Interfaces For High-Impact Projectile Resistance","abstract":"In this study, the thermal resistance, flexural behavior, and impact resistance via hurricane impact loads of two-wythe precast concrete composite sandwich beams comprised of an intermediate carbon-fiber epoxy inter-facially bonded to a dual Hybrid Matrix Composite (HMC) were investigated as an affordable alternative for enhancing thermal and mechanical (debris-impact and flexural) properties. The study is a precursor to the design of Precast Concrete Sandwich Panels (PCSP). HMC is a chemical reaction between a thermosetting epoxy network and a fast-setting, yet highly reactive, isocyanate-amine system at a pre-polymerized stage. The interfacial reaction of HMC is a function of epoxy curing kinetics, resin viscosity, and polyurea-type, enabling mechanical and thermal behaviors to be aptly modified. Thirteen thin two-wythe (2.5-in per wythe) concrete beams were quasi-statically tested under 4-point loading; twelve HMC specimens were tested for thermal conductivity and resistivity (R-Value); and nine concrete panels were impact-tested, engendering enhanced mechanical and thermal behavior relative to conventional fiber-reinforced composites (FRP) and also to current industry-standard expanded polystyrene (EPS) and extruded polystyrene (XPS) insulation. Test results indicate that panels integrated with HMC designed with a lower-viscosity resin ( = 696 cps) and an epoxy curing time of 0.5 hours, where the epoxy network reacts with an aliphatic polyurea to elicit excellent dual thermal-mechanical performance. In this scenario, energy absorption, and R-value, using a heat flow meter apparatus, were calculated as 7.9 kJ and 4.71 hr∙ft2∙°F/(Btu∙in) respectively. Although thermal resistance (R-value) in counterpart XPS standard insulation systems was found to reach R-4.76 hr∙ft2∙°F/(Btu∙in), strength, energy absorption, and ductility were limited. Furthermore, composite beam action, or the shear transfer mechanism, at service and ultimate conditions in the highest-performing sample was calculated using stiffness and strength methods that elicited 22% and 337% respectively, deducing that HMC is an affordable dual-purpose insulation alternative in the multi-wythe construction of large precast tilt-up walls. A finite element model was developed to simulate PCSPs with HMC intermediate layer materials. indicating enormous potential of HMC as a dual thermal-mechanical system in tilt-up wall constructions.","abstract_html":"In this study, the thermal resistance, flexural behavior, and impact resistance via hurricane impact loads of two-wythe precast concrete composite sandwich beams comprised of an intermediate carbon-fiber epoxy inter-facially bonded to a dual Hybrid Matrix Composite (HMC) were investigated as an affordable alternative for enhancing thermal and mechanical (debris-impact and flexural) properties. The study is a precursor to the design of Precast Concrete Sandwich Panels (PCSP). HMC is a chemical reaction between a thermosetting epoxy network and a fast-setting, yet highly reactive, isocyanate-amine system at a pre-polymerized stage. The interfacial reaction of HMC is a function of epoxy curing kinetics, resin viscosity, and polyurea-type, enabling mechanical and thermal behaviors to be aptly modified. Thirteen thin two-wythe (2.5-in per wythe) concrete beams were quasi-statically tested under 4-point loading; twelve HMC specimens were tested for thermal conductivity and resistivity (R-Value); and nine concrete panels were impact-tested, engendering enhanced mechanical and thermal behavior relative to conventional fiber-reinforced composites (FRP) and also to current industry-standard expanded polystyrene (EPS) and extruded polystyrene (XPS) insulation. Test results indicate that panels integrated with HMC designed with a lower-viscosity resin ( = 696 cps) and an epoxy curing time of 0.5 hours, where the epoxy network reacts with an aliphatic polyurea to elicit excellent dual thermal-mechanical performance. In this scenario, energy absorption, and R-value, using a heat flow meter apparatus, were calculated as 7.9 kJ and 4.71 hr∙ft2∙°F/(Btu∙in) respectively. Although thermal resistance (R-value) in counterpart XPS standard insulation systems was found to reach R-4.76 hr∙ft2∙°F/(Btu∙in), strength, energy absorption, and ductility were limited. Furthermore, composite beam action, or the shear transfer mechanism, at service and ultimate conditions in the highest-performing sample was calculated using stiffness and strength methods that elicited 22% and 337% respectively, deducing that HMC is an affordable dual-purpose insulation alternative in the multi-wythe construction of large precast tilt-up walls. A finite element model was developed to simulate PCSPs with HMC intermediate layer materials. indicating enormous potential of HMC as a dual thermal-mechanical system in tilt-up wall constructions.","abstract_has_math":false,"creators":["Avalos, Hector R Orozco"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Thomas L Attard","Cristopher Waldron","Vinoy Thomas"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:27:57Z","subjects":["composite action","fiber-reinforced polymer","hybrid matrix composite","polyurea","Precast concrete sandwich wall panels","thermaly efficiency","Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.library.uab.edu/etd-collection/2635","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.library.uab.edu/etd-collection/2635","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.library.uab.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.library.uab.edu%3Aetd-collection-3627","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Thomas L Attard","Cristopher Waldron","Vinoy Thomas"]},{"key":"dc:creator","label":"Author","values":["Avalos, Hector R Orozco"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["composite action","fiber-reinforced polymer","hybrid matrix composite","polyurea","Precast concrete sandwich wall panels","thermaly efficiency","Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.library.uab.edu/etd-collection/2635"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this study, the thermal resistance, flexural behavior, and impact resistance via hurricane impact loads of two-wythe precast concrete composite sandwich beams comprised of an intermediate carbon-fiber epoxy inter-facially bonded to a dual Hybrid Matrix Composite (HMC) were investigated as an affordable alternative for enhancing thermal and mechanical (debris-impact and flexural) properties. The study is a precursor to the design of Precast Concrete Sandwich Panels (PCSP). HMC is a chemical reaction between a thermosetting epoxy network and a fast-setting, yet highly reactive, isocyanate-amine system at a pre-polymerized stage. The interfacial reaction of HMC is a function of epoxy curing kinetics, resin viscosity, and polyurea-type, enabling mechanical and thermal behaviors to be aptly modified. Thirteen thin two-wythe (2.5-in per wythe) concrete beams were quasi-statically tested under 4-point loading; twelve HMC specimens were tested for thermal conductivity and resistivity (R-Value); and nine concrete panels were impact-tested, engendering enhanced mechanical and thermal behavior relative to conventional fiber-reinforced composites (FRP) and also to current industry-standard expanded polystyrene (EPS) and extruded polystyrene (XPS) insulation. Test results indicate that panels integrated with HMC designed with a lower-viscosity resin ( = 696 cps) and an epoxy curing time of 0.5 hours, where the epoxy network reacts with an aliphatic polyurea to elicit excellent dual thermal-mechanical performance. In this scenario, energy absorption, and R-value, using a heat flow meter apparatus, were calculated as 7.9 kJ and 4.71 hr∙ft2∙°F/(Btu∙in) respectively. Although thermal resistance (R-value) in counterpart XPS standard insulation systems was found to reach R-4.76 hr∙ft2∙°F/(Btu∙in), strength, energy absorption, and ductility were limited. Furthermore, composite beam action, or the shear transfer mechanism, at service and ultimate conditions in the highest-performing sample was calculated using stiffness and strength methods that elicited 22% and 337% respectively, deducing that HMC is an affordable dual-purpose insulation alternative in the multi-wythe construction of large precast tilt-up walls. A finite element model was developed to simulate PCSPs with HMC intermediate layer materials. indicating enormous potential of HMC as a dual thermal-mechanical system in tilt-up wall constructions."]},{"key":"dc:description.note","label":"Dc Description Note","values":["etdadmin_upload_575661"]},{"key":"dc:title","label":"Title","values":["Thermal-Mechanical Precast Concrete Panels Comprised Of Hybrid-Polymerized Sandwich Interfaces For High-Impact Projectile Resistance"]}]}],"canonical_facts":{"dc:contributor":["Thomas L Attard","Cristopher Waldron","Vinoy Thomas"],"dc:creator":["Avalos, Hector R Orozco"],"dc:date.created":["2018-01-01T08:00:00Z"],"dc:description.abstract":["In this study, the thermal resistance, flexural behavior, and impact resistance via hurricane impact loads of two-wythe precast concrete composite sandwich beams comprised of an intermediate carbon-fiber epoxy inter-facially bonded to a dual Hybrid Matrix Composite (HMC) were investigated as an affordable alternative for enhancing thermal and mechanical (debris-impact and flexural) properties. The study is a precursor to the design of Precast Concrete Sandwich Panels (PCSP). HMC is a chemical reaction between a thermosetting epoxy network and a fast-setting, yet highly reactive, isocyanate-amine system at a pre-polymerized stage. The interfacial reaction of HMC is a function of epoxy curing kinetics, resin viscosity, and polyurea-type, enabling mechanical and thermal behaviors to be aptly modified. Thirteen thin two-wythe (2.5-in per wythe) concrete beams were quasi-statically tested under 4-point loading; twelve HMC specimens were tested for thermal conductivity and resistivity (R-Value); and nine concrete panels were impact-tested, engendering enhanced mechanical and thermal behavior relative to conventional fiber-reinforced composites (FRP) and also to current industry-standard expanded polystyrene (EPS) and extruded polystyrene (XPS) insulation. Test results indicate that panels integrated with HMC designed with a lower-viscosity resin ( = 696 cps) and an epoxy curing time of 0.5 hours, where the epoxy network reacts with an aliphatic polyurea to elicit excellent dual thermal-mechanical performance. In this scenario, energy absorption, and R-value, using a heat flow meter apparatus, were calculated as 7.9 kJ and 4.71 hr∙ft2∙°F/(Btu∙in) respectively. Although thermal resistance (R-value) in counterpart XPS standard insulation systems was found to reach R-4.76 hr∙ft2∙°F/(Btu∙in), strength, energy absorption, and ductility were limited. Furthermore, composite beam action, or the shear transfer mechanism, at service and ultimate conditions in the highest-performing sample was calculated using stiffness and strength methods that elicited 22% and 337% respectively, deducing that HMC is an affordable dual-purpose insulation alternative in the multi-wythe construction of large precast tilt-up walls. A finite element model was developed to simulate PCSPs with HMC intermediate layer materials. indicating enormous potential of HMC as a dual thermal-mechanical system in tilt-up wall constructions."],"dc:description.note":["etdadmin_upload_575661"],"dc:identifier":["https://digitalcommons.library.uab.edu/etd-collection/2635"],"dc:subject":["composite action","fiber-reinforced polymer","hybrid matrix composite","polyurea","Precast concrete sandwich wall panels","thermaly efficiency","Engineering"],"dc:title":["Thermal-Mechanical Precast Concrete Panels Comprised Of Hybrid-Polymerized Sandwich Interfaces For High-Impact Projectile Resistance"],"thesis:degree_level":["Thesis"]},"updated_at":"2026-11-19T09:27:57Z"}