{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/10739"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/10739","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Open architecture controllers : real-time capabilities and interoperability","abstract":"Open architecture controllers are used in manufacturing systems for providing reconfigurability, extendibility, and portability of control modules. One drawback of current open architecture controller standards is that they do not include specifications for real-time requirements. Another drawback is that it is not possible to use a control application defined for one standard on another open architecture controller. Furthermore, an application running on one open architecture controller cannot communicate with an application implemented using a different standard. In this thesis, the application programmers interfaces of two open architecture controllers, namely OSACA and ORTS, are examined in terms of their hard real-time specifications. Two interfaces are developed and implemented for exchanging data between ORTS, a small memory real-time operating system, and other open architecture control systems. The first interface provides a bridge between ORTS and the European initiated open architecture control standard, OSACA. This TCP/IP based interface enables data transfer between ORTS and OSACA applications which can be implemented on a wide range of different platforms. The second interface provides a bridge between ORTS and the open architecture CNC, ISG NC Kernel. The interface uses shared memory and is therefore advantageous for small memory, high speed applications such as intelligent machining, monitoring and control applications.","abstract_html":"Open architecture controllers are used in manufacturing systems for providing reconfigurability, extendibility, and portability of control modules. One drawback of current open architecture controller standards is that they do not include specifications for real-time requirements. Another drawback is that it is not possible to use a control application defined for one standard on another open architecture controller. Furthermore, an application running on one open architecture controller cannot communicate with an application implemented using a different standard. In this thesis, the application programmers interfaces of two open architecture controllers, namely OSACA and ORTS, are examined in terms of their hard real-time specifications. Two interfaces are developed and implemented for exchanging data between ORTS, a small memory real-time operating system, and other open architecture control systems. The first interface provides a bridge between ORTS and the European initiated open architecture control standard, OSACA. This TCP/IP based interface enables data transfer between ORTS and OSACA applications which can be implemented on a wide range of different platforms. The second interface provides a bridge between ORTS and the open architecture CNC, ISG NC Kernel. The interface uses shared memory and is therefore advantageous for small memory, high speed applications such as intelligent machining, monitoring and control applications.","abstract_has_math":false,"creators":["Õtkũnc, Cemile Bũke"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000","date_published":"2000","updated_at":"2026-11-19T14:29:04Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/10739","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/10739","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/10739/1/ubc_2000-0515.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F10739","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Õtkũnc, Cemile Bũke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2000"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/10739","http://circle.library.ubc.ca/bitstream/2429/10739/1/ubc_2000-0515.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Open architecture controllers are used in manufacturing systems for providing reconfigurability, extendibility, and portability of control modules. One drawback of current open architecture controller standards is that they do not include specifications for real-time requirements. Another drawback is that it is not possible to use a control application defined for one standard on another open architecture controller. Furthermore, an application running on one open architecture controller cannot communicate with an application implemented using a different standard. In this thesis, the application programmers interfaces of two open architecture controllers, namely OSACA and ORTS, are examined in terms of their hard real-time specifications. Two interfaces are developed and implemented for exchanging data between ORTS, a small memory real-time operating system, and other open architecture control systems. The first interface provides a bridge between ORTS and the European initiated open architecture control standard, OSACA. This TCP/IP based interface enables data transfer between ORTS and OSACA applications which can be implemented on a wide range of different platforms. The second interface provides a bridge between ORTS and the open architecture CNC, ISG NC Kernel. The interface uses shared memory and is therefore advantageous for small memory, high speed applications such as intelligent machining, monitoring and control applications."]},{"key":"dc:format","label":"Dc Format","values":["3425446","application/pdf"]},{"key":"dc:title","label":"Title","values":["Open architecture controllers : real-time capabilities and interoperability"]}]}],"canonical_facts":{"dc:creator":["Õtkũnc, Cemile Bũke"],"dc:date":["2000"],"dc:description":["Open architecture controllers are used in manufacturing systems for providing reconfigurability, extendibility, and portability of control modules. One drawback of current open architecture controller standards is that they do not include specifications for real-time requirements. Another drawback is that it is not possible to use a control application defined for one standard on another open architecture controller. Furthermore, an application running on one open architecture controller cannot communicate with an application implemented using a different standard. In this thesis, the application programmers interfaces of two open architecture controllers, namely OSACA and ORTS, are examined in terms of their hard real-time specifications. Two interfaces are developed and implemented for exchanging data between ORTS, a small memory real-time operating system, and other open architecture control systems. The first interface provides a bridge between ORTS and the European initiated open architecture control standard, OSACA. This TCP/IP based interface enables data transfer between ORTS and OSACA applications which can be implemented on a wide range of different platforms. The second interface provides a bridge between ORTS and the open architecture CNC, ISG NC Kernel. The interface uses shared memory and is therefore advantageous for small memory, high speed applications such as intelligent machining, monitoring and control applications."],"dc:format":["3425446","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/10739","http://circle.library.ubc.ca/bitstream/2429/10739/1/ubc_2000-0515.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Open architecture controllers : real-time capabilities and interoperability"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:29:04Z"}