{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/11070"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/11070","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Functional dynamic spect imaging using a single slow camera rotation","abstract":"Dynamic single photon emission computed tomography (SPECT) is a relatively new imaging method that uses radioactive tracers and tomographic data acquisition techniques in order to quantify temporal changes in regional radiotracer concentrations within a patient. This is important as the rate of change in tracer concentration within an organ often can be related to the functional ability of that organ. In this work, a new method is presented that is able to determine these kinetic rates while using a conventional single or multiple detector SPECT camera, and more importantly, a single, slow camera rotation in the data collection process (herein this reconstruction method will be referred to as dSPECT). This reconstruction method is based on the fact that a temporal change in the activity concentration at a given location can be represented by a linear inequality constraint over time. Two iterative reconstruction algorithms, constrained least squares (CLS) and dynamic expectation maximization (dEM), have been tested using this approach with a variety of computer simulations and phantom experiments. In simulations involving a slow dynamic change of activity, results indicate that the dSPECT reconstruction procedure typically produces kinetic parameter estimates with a 7% error when using projection data acquired with a single 180° rotation of a triple headed SPECT camera system. This error increases to about 15% for data acquired with a dual head system and further increases to about 50% for single detector acquisitions. When simulated with faster dynamic parameters, errors increased slightly to about 8%, 12% and 55% for acquisitions involving triple, dual and single head systems respectively.","abstract_html":"Dynamic single photon emission computed tomography (SPECT) is a relatively new imaging method that uses radioactive tracers and tomographic data acquisition techniques in order to quantify temporal changes in regional radiotracer concentrations within a patient. This is important as the rate of change in tracer concentration within an organ often can be related to the functional ability of that organ. In this work, a new method is presented that is able to determine these kinetic rates while using a conventional single or multiple detector SPECT camera, and more importantly, a single, slow camera rotation in the data collection process (herein this reconstruction method will be referred to as dSPECT). This reconstruction method is based on the fact that a temporal change in the activity concentration at a given location can be represented by a linear inequality constraint over time. Two iterative reconstruction algorithms, constrained least squares (CLS) and dynamic expectation maximization (dEM), have been tested using this approach with a variety of computer simulations and phantom experiments. In simulations involving a slow dynamic change of activity, results indicate that the dSPECT reconstruction procedure typically produces kinetic parameter estimates with a 7% error when using projection data acquired with a single 180° rotation of a triple headed SPECT camera system. This error increases to about 15% for data acquired with a dual head system and further increases to about 50% for single detector acquisitions. When simulated with faster dynamic parameters, errors increased slightly to about 8%, 12% and 55% for acquisitions involving triple, dual and single head systems respectively.","abstract_has_math":false,"creators":["Farncombe, Troy"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2000,"date_issued":"2000","date_published":"2000","updated_at":"2026-11-19T14:31:34Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/11070","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/11070","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/11070/1/ubc_2000-565394.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F11070","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Farncombe, Troy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2000"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/11070","http://circle.library.ubc.ca/bitstream/2429/11070/1/ubc_2000-565394.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Dynamic single photon emission computed tomography (SPECT) is a relatively new imaging method that uses radioactive tracers and tomographic data acquisition techniques in order to quantify temporal changes in regional radiotracer concentrations within a patient. This is important as the rate of change in tracer concentration within an organ often can be related to the functional ability of that organ. In this work, a new method is presented that is able to determine these kinetic rates while using a conventional single or multiple detector SPECT camera, and more importantly, a single, slow camera rotation in the data collection process (herein this reconstruction method will be referred to as dSPECT). This reconstruction method is based on the fact that a temporal change in the activity concentration at a given location can be represented by a linear inequality constraint over time. Two iterative reconstruction algorithms, constrained least squares (CLS) and dynamic expectation maximization (dEM), have been tested using this approach with a variety of computer simulations and phantom experiments. In simulations involving a slow dynamic change of activity, results indicate that the dSPECT reconstruction procedure typically produces kinetic parameter estimates with a 7% error when using projection data acquired with a single 180° rotation of a triple headed SPECT camera system. This error increases to about 15% for data acquired with a dual head system and further increases to about 50% for single detector acquisitions. When simulated with faster dynamic parameters, errors increased slightly to about 8%, 12% and 55% for acquisitions involving triple, dual and single head systems respectively."]},{"key":"dc:format","label":"Dc Format","values":["27330709","application/pdf"]},{"key":"dc:title","label":"Title","values":["Functional dynamic spect imaging using a single slow camera rotation"]}]}],"canonical_facts":{"dc:creator":["Farncombe, Troy"],"dc:date":["2000"],"dc:description":["Dynamic single photon emission computed tomography (SPECT) is a relatively new imaging method that uses radioactive tracers and tomographic data acquisition techniques in order to quantify temporal changes in regional radiotracer concentrations within a patient. This is important as the rate of change in tracer concentration within an organ often can be related to the functional ability of that organ. In this work, a new method is presented that is able to determine these kinetic rates while using a conventional single or multiple detector SPECT camera, and more importantly, a single, slow camera rotation in the data collection process (herein this reconstruction method will be referred to as dSPECT). This reconstruction method is based on the fact that a temporal change in the activity concentration at a given location can be represented by a linear inequality constraint over time. Two iterative reconstruction algorithms, constrained least squares (CLS) and dynamic expectation maximization (dEM), have been tested using this approach with a variety of computer simulations and phantom experiments. In simulations involving a slow dynamic change of activity, results indicate that the dSPECT reconstruction procedure typically produces kinetic parameter estimates with a 7% error when using projection data acquired with a single 180° rotation of a triple headed SPECT camera system. This error increases to about 15% for data acquired with a dual head system and further increases to about 50% for single detector acquisitions. When simulated with faster dynamic parameters, errors increased slightly to about 8%, 12% and 55% for acquisitions involving triple, dual and single head systems respectively."],"dc:format":["27330709","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/11070","http://circle.library.ubc.ca/bitstream/2429/11070/1/ubc_2000-565394.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Functional dynamic spect imaging using a single slow camera rotation"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:31:34Z"}