{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/11277"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/11277","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Geogrid-soil interaction coefficients for seismic design","abstract":"Tensar uniaxial geogrids were subjected to load-controlled monotonic and cyclic pullout testing to determine the relative coefficients of interaction. The variables investigated were geogrid series (UX1500SB, UX1400HS, and UX1600HS), soil type (poorly-graded medium fine sand and poorly-graded silty fine sand-sized glass beads) and normal stress (5, 10, and 20 kPa). The geogrid specimens, roughly 0.5 m wide by 1.5 m long, were strain-gauged to allow description of pullout behavior at small displacements. Results suggest that irrespective of geogrid series, soil type, or normal stress the soil-geogrid interaction is approximately equal under monotonic and cyclic loading. Additionally, at the frequency of cycles used, the geogrids did not pull out catastrophically but instead displaced incrementally in a controlled manner when the cyclic load exceeded the peak load sustained by the geogrid under monotonic loading.","abstract_html":"Tensar uniaxial geogrids were subjected to load-controlled monotonic and cyclic pullout testing to determine the relative coefficients of interaction. The variables investigated were geogrid series (UX1500SB, UX1400HS, and UX1600HS), soil type (poorly-graded medium fine sand and poorly-graded silty fine sand-sized glass beads) and normal stress (5, 10, and 20 kPa). The geogrid specimens, roughly 0.5 m wide by 1.5 m long, were strain-gauged to allow description of pullout behavior at small displacements. Results suggest that irrespective of geogrid series, soil type, or normal stress the soil-geogrid interaction is approximately equal under monotonic and cyclic loading. Additionally, at the frequency of cycles used, the geogrids did not pull out catastrophically but instead displaced incrementally in a controlled manner when the cyclic load exceeded the peak load sustained by the geogrid under monotonic loading.","abstract_has_math":false,"creators":["Duckworth, Shane M."],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-11-19T14:31:48Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/11277","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/11277","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/11277/1/ubc_2001-0022.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F11277","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Duckworth, Shane M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2001"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/11277","http://circle.library.ubc.ca/bitstream/2429/11277/1/ubc_2001-0022.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Tensar uniaxial geogrids were subjected to load-controlled monotonic and cyclic pullout testing to determine the relative coefficients of interaction. The variables investigated were geogrid series (UX1500SB, UX1400HS, and UX1600HS), soil type (poorly-graded medium fine sand and poorly-graded silty fine sand-sized glass beads) and normal stress (5, 10, and 20 kPa). The geogrid specimens, roughly 0.5 m wide by 1.5 m long, were strain-gauged to allow description of pullout behavior at small displacements. Results suggest that irrespective of geogrid series, soil type, or normal stress the soil-geogrid interaction is approximately equal under monotonic and cyclic loading. Additionally, at the frequency of cycles used, the geogrids did not pull out catastrophically but instead displaced incrementally in a controlled manner when the cyclic load exceeded the peak load sustained by the geogrid under monotonic loading."]},{"key":"dc:format","label":"Dc Format","values":["4894937","application/pdf"]},{"key":"dc:title","label":"Title","values":["Geogrid-soil interaction coefficients for seismic design"]}]}],"canonical_facts":{"dc:creator":["Duckworth, Shane M."],"dc:date":["2001"],"dc:description":["Tensar uniaxial geogrids were subjected to load-controlled monotonic and cyclic pullout testing to determine the relative coefficients of interaction. The variables investigated were geogrid series (UX1500SB, UX1400HS, and UX1600HS), soil type (poorly-graded medium fine sand and poorly-graded silty fine sand-sized glass beads) and normal stress (5, 10, and 20 kPa). The geogrid specimens, roughly 0.5 m wide by 1.5 m long, were strain-gauged to allow description of pullout behavior at small displacements. Results suggest that irrespective of geogrid series, soil type, or normal stress the soil-geogrid interaction is approximately equal under monotonic and cyclic loading. Additionally, at the frequency of cycles used, the geogrids did not pull out catastrophically but instead displaced incrementally in a controlled manner when the cyclic load exceeded the peak load sustained by the geogrid under monotonic loading."],"dc:format":["4894937","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/11277","http://circle.library.ubc.ca/bitstream/2429/11277/1/ubc_2001-0022.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Geogrid-soil interaction coefficients for seismic design"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:31:48Z"}