{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/12034"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/12034","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Measurements of heat capacity and heat transfer coefficient of water-oxygen mixtures at near critical conditions","abstract":"The constant-pressure heat capacity, Cp, and local forced convection heat transfer coefficient, h, for water-oxygen mixtures flowing inside horizontal smooth tubes were obtained experimentally. Data were obtained for pressures of 24 to 26 MPa; flow rates 0.636 to 1.27 l/min, average heat fluxes 34 to 160 kW/m², mass velocities 351 to 701 kg/m²s and temperatures from 330 to 430 °C. Oxygen flow was 2 to 8 weight percentage of the total mixture flow. For a given flow and heat supplied to the mixture, Cp is determined from the bulk temperature in a heated tube. The heat transfer coefficient, h is determined from the difference in bulk and wall temperatures. The temperature at which the maximum heat capacity occurs (Tpc) is lower for water-oxygen mixtures than for pure water. Another effect of oxygen addition is a reduction in magnitude of the maximum Cp and h. The enhancement near the critical point appears to be less at high heat flux.","abstract_html":"The constant-pressure heat capacity, Cp, and local forced convection heat transfer coefficient, h, for water-oxygen mixtures flowing inside horizontal smooth tubes were obtained experimentally. Data were obtained for pressures of 24 to 26 MPa; flow rates 0.636 to 1.27 l/min, average heat fluxes 34 to 160 kW/m², mass velocities 351 to 701 kg/m²s and temperatures from 330 to 430 °C. Oxygen flow was 2 to 8 weight percentage of the total mixture flow. For a given flow and heat supplied to the mixture, Cp is determined from the bulk temperature in a heated tube. The heat transfer coefficient, h is determined from the difference in bulk and wall temperatures. The temperature at which the maximum heat capacity occurs (Tpc) is lower for water-oxygen mixtures than for pure water. Another effect of oxygen addition is a reduction in magnitude of the maximum Cp and h. The enhancement near the critical point appears to be less at high heat flux.","abstract_has_math":false,"creators":["Boskovic, Sanja"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2001,"date_issued":"2001","date_published":"2001","updated_at":"2026-11-19T14:32:55Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/12034","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/12034","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/12034/1/ubc_2002-0024.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F12034","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Boskovic, Sanja"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2001"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/12034","http://circle.library.ubc.ca/bitstream/2429/12034/1/ubc_2002-0024.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The constant-pressure heat capacity, Cp, and local forced convection heat transfer coefficient, h, for water-oxygen mixtures flowing inside horizontal smooth tubes were obtained experimentally. Data were obtained for pressures of 24 to 26 MPa; flow rates 0.636 to 1.27 l/min, average heat fluxes 34 to 160 kW/m², mass velocities 351 to 701 kg/m²s and temperatures from 330 to 430 °C. Oxygen flow was 2 to 8 weight percentage of the total mixture flow. For a given flow and heat supplied to the mixture, Cp is determined from the bulk temperature in a heated tube. The heat transfer coefficient, h is determined from the difference in bulk and wall temperatures. The temperature at which the maximum heat capacity occurs (Tpc) is lower for water-oxygen mixtures than for pure water. Another effect of oxygen addition is a reduction in magnitude of the maximum Cp and h. The enhancement near the critical point appears to be less at high heat flux."]},{"key":"dc:format","label":"Dc Format","values":["7787634","application/pdf"]},{"key":"dc:title","label":"Title","values":["Measurements of heat capacity and heat transfer coefficient of water-oxygen mixtures at near critical conditions"]}]}],"canonical_facts":{"dc:creator":["Boskovic, Sanja"],"dc:date":["2001"],"dc:description":["The constant-pressure heat capacity, Cp, and local forced convection heat transfer coefficient, h, for water-oxygen mixtures flowing inside horizontal smooth tubes were obtained experimentally. Data were obtained for pressures of 24 to 26 MPa; flow rates 0.636 to 1.27 l/min, average heat fluxes 34 to 160 kW/m², mass velocities 351 to 701 kg/m²s and temperatures from 330 to 430 °C. Oxygen flow was 2 to 8 weight percentage of the total mixture flow. For a given flow and heat supplied to the mixture, Cp is determined from the bulk temperature in a heated tube. The heat transfer coefficient, h is determined from the difference in bulk and wall temperatures. The temperature at which the maximum heat capacity occurs (Tpc) is lower for water-oxygen mixtures than for pure water. Another effect of oxygen addition is a reduction in magnitude of the maximum Cp and h. The enhancement near the critical point appears to be less at high heat flux."],"dc:format":["7787634","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/12034","http://circle.library.ubc.ca/bitstream/2429/12034/1/ubc_2002-0024.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Measurements of heat capacity and heat transfer coefficient of water-oxygen mixtures at near critical conditions"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:32:55Z"}