{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/16468"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/16468","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN","abstract":"The TITAN (TRIUMF'S Ion Trap for Atomic and Nuclear science) project at TRIUMF will use the unique combination of an Electron Beam Ion Trap (EBIT) charge state breeder and a precision Penning trap to carry out high accuracy mass measurements (δm/m ≈ 1 x 10⁻⁸) on short-lived (t₁/₂≈ 50 ms) isotopes. In order to obtain fast and efficient charge state breeding it is necessary to inject a cooled and bunched beam into the EBIT. For radioactive isotopes this can be achieved by employing a segmented, gas-filled, RadioFrequency Quadrupole (RFQ). Such a device has been developed for use in the TITAN experiment. Previous RFQ coolers have been driven sinusoidally, however this device will be driven with a large amplitude (V[sub pp] = 400 V) high frequency (f = 1 MHz) square-wave. This makes a broadband, linear, cooling trap possible for the first time. Using matrix methods the motion of ions in a square-wave-driven trap were studied and the acceptance and the space charge limit of the trap calculated as a function of the operating parameter, q. A simple viscous drag model for the cooling process was then used to prove the cooling concept. A Monte Carlo routine was developed and used to simulate the cooling of cesium ions in a helium buffer gas. At an operating parameter of q = 0.4 a cooling time of 600/μs was found at a gas pressure of 2.5 x 10⁻² mbar. The final temperature, T[sub f], of the ion cloud was found as a function of q (for q < 0.4, T[sub f] < 400 K)- Ion optics for the injection and the extraction of ions from the trap were designed and simulated. Transverse rms emittances on the order of 3 π mm mrad and longitudinal rms emittances on the order of 2 eV μs for the extracted beam were demonstrated at an extraction energy of 2.5 keV. Simulations of a previously designed and manufactured stable ion source system were carried out to try and match the emittance of the beam to the acceptance of the RFQ. Through a combination of simulation and experimental results it was shown that with minor modification the system would give a relatively good approximation to the actual radioactive ion beam produced at TRIUMF. Further simulations showed that an acceptance of 99.8% of the modified beam by the RFQ will be possible.","abstract_html":"The TITAN (TRIUMF&#x27;S Ion Trap for Atomic and Nuclear science) project at TRIUMF will use the unique combination of an Electron Beam Ion Trap (EBIT) charge state breeder and a precision Penning trap to carry out high accuracy mass measurements (δm/m ≈ 1 x 10⁻⁸) on short-lived (t₁/₂≈ 50 ms) isotopes. In order to obtain fast and efficient charge state breeding it is necessary to inject a cooled and bunched beam into the EBIT. For radioactive isotopes this can be achieved by employing a segmented, gas-filled, RadioFrequency Quadrupole (RFQ). Such a device has been developed for use in the TITAN experiment. Previous RFQ coolers have been driven sinusoidally, however this device will be driven with a large amplitude (V[sub pp] = 400 V) high frequency (f = 1 MHz) square-wave. This makes a broadband, linear, cooling trap possible for the first time. Using matrix methods the motion of ions in a square-wave-driven trap were studied and the acceptance and the space charge limit of the trap calculated as a function of the operating parameter, q. A simple viscous drag model for the cooling process was then used to prove the cooling concept. A Monte Carlo routine was developed and used to simulate the cooling of cesium ions in a helium buffer gas. At an operating parameter of q = 0.4 a cooling time of 600/μs was found at a gas pressure of 2.5 x 10⁻² mbar. The final temperature, T[sub f], of the ion cloud was found as a function of q (for q &lt; 0.4, T[sub f] &lt; 400 K)- Ion optics for the injection and the extraction of ions from the trap were designed and simulated. Transverse rms emittances on the order of 3 π mm mrad and longitudinal rms emittances on the order of 2 eV μs for the extracted beam were demonstrated at an extraction energy of 2.5 keV. Simulations of a previously designed and manufactured stable ion source system were carried out to try and match the emittance of the beam to the acceptance of the RFQ. Through a combination of simulation and experimental results it was shown that with minor modification the system would give a relatively good approximation to the actual radioactive ion beam produced at TRIUMF. Further simulations showed that an acceptance of 99.8% of the modified beam by the RFQ will be possible.","abstract_has_math":false,"creators":["Smith, Mathew"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-19T14:35:10Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/16468","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/16468","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/16468/1/ubc_2005-0322.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F16468","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Smith, Mathew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/16468","http://circle.library.ubc.ca/bitstream/2429/16468/1/ubc_2005-0322.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The TITAN (TRIUMF'S Ion Trap for Atomic and Nuclear science) project at TRIUMF will use the unique combination of an Electron Beam Ion Trap (EBIT) charge state breeder and a precision Penning trap to carry out high accuracy mass measurements (δm/m ≈ 1 x 10⁻⁸) on short-lived (t₁/₂≈ 50 ms) isotopes. In order to obtain fast and efficient charge state breeding it is necessary to inject a cooled and bunched beam into the EBIT. For radioactive isotopes this can be achieved by employing a segmented, gas-filled, RadioFrequency Quadrupole (RFQ). Such a device has been developed for use in the TITAN experiment. Previous RFQ coolers have been driven sinusoidally, however this device will be driven with a large amplitude (V[sub pp] = 400 V) high frequency (f = 1 MHz) square-wave. This makes a broadband, linear, cooling trap possible for the first time. Using matrix methods the motion of ions in a square-wave-driven trap were studied and the acceptance and the space charge limit of the trap calculated as a function of the operating parameter, q. A simple viscous drag model for the cooling process was then used to prove the cooling concept. A Monte Carlo routine was developed and used to simulate the cooling of cesium ions in a helium buffer gas. At an operating parameter of q = 0.4 a cooling time of 600/μs was found at a gas pressure of 2.5 x 10⁻² mbar. The final temperature, T[sub f], of the ion cloud was found as a function of q (for q < 0.4, T[sub f] < 400 K)- Ion optics for the injection and the extraction of ions from the trap were designed and simulated. Transverse rms emittances on the order of 3 π mm mrad and longitudinal rms emittances on the order of 2 eV μs for the extracted beam were demonstrated at an extraction energy of 2.5 keV. Simulations of a previously designed and manufactured stable ion source system were carried out to try and match the emittance of the beam to the acceptance of the RFQ. Through a combination of simulation and experimental results it was shown that with minor modification the system would give a relatively good approximation to the actual radioactive ion beam produced at TRIUMF. Further simulations showed that an acceptance of 99.8% of the modified beam by the RFQ will be possible."]},{"key":"dc:format","label":"Dc Format","values":["8973150","application/pdf"]},{"key":"dc:title","label":"Title","values":["A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN"]}]}],"canonical_facts":{"dc:creator":["Smith, Mathew"],"dc:date":["2005"],"dc:description":["The TITAN (TRIUMF'S Ion Trap for Atomic and Nuclear science) project at TRIUMF will use the unique combination of an Electron Beam Ion Trap (EBIT) charge state breeder and a precision Penning trap to carry out high accuracy mass measurements (δm/m ≈ 1 x 10⁻⁸) on short-lived (t₁/₂≈ 50 ms) isotopes. In order to obtain fast and efficient charge state breeding it is necessary to inject a cooled and bunched beam into the EBIT. For radioactive isotopes this can be achieved by employing a segmented, gas-filled, RadioFrequency Quadrupole (RFQ). Such a device has been developed for use in the TITAN experiment. Previous RFQ coolers have been driven sinusoidally, however this device will be driven with a large amplitude (V[sub pp] = 400 V) high frequency (f = 1 MHz) square-wave. This makes a broadband, linear, cooling trap possible for the first time. Using matrix methods the motion of ions in a square-wave-driven trap were studied and the acceptance and the space charge limit of the trap calculated as a function of the operating parameter, q. A simple viscous drag model for the cooling process was then used to prove the cooling concept. A Monte Carlo routine was developed and used to simulate the cooling of cesium ions in a helium buffer gas. At an operating parameter of q = 0.4 a cooling time of 600/μs was found at a gas pressure of 2.5 x 10⁻² mbar. The final temperature, T[sub f], of the ion cloud was found as a function of q (for q < 0.4, T[sub f] < 400 K)- Ion optics for the injection and the extraction of ions from the trap were designed and simulated. Transverse rms emittances on the order of 3 π mm mrad and longitudinal rms emittances on the order of 2 eV μs for the extracted beam were demonstrated at an extraction energy of 2.5 keV. Simulations of a previously designed and manufactured stable ion source system were carried out to try and match the emittance of the beam to the acceptance of the RFQ. Through a combination of simulation and experimental results it was shown that with minor modification the system would give a relatively good approximation to the actual radioactive ion beam produced at TRIUMF. Further simulations showed that an acceptance of 99.8% of the modified beam by the RFQ will be possible."],"dc:format":["8973150","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/16468","http://circle.library.ubc.ca/bitstream/2429/16468/1/ubc_2005-0322.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A square-wave-driven radiofrequency quadrupole cooler and buncher for TITAN"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:35:10Z"}