{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/16915"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/16915","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Effect of atmospheric pressure ion lens on an electrospray ion source","abstract":"The effect of an atmospheric pressure ion lens on electrospray ionization mass spectrometry (ESI-MS) was investigated. In Chapter 2, the voltage combinations applied to the spray and the ion lens were systematically studied, as well as the current-voltage relationship. The ion lens showed its ability to widen the range of operational spray voltages and improve signal intensity. Through the calculations in Chapter 3, the effect ofthe ion lens is demonstrated to include improving the electrospray process by changing the field strength and widening the operational spray voltage range, and increasing the transmission efficiency by focusing ions through the flattened equipotential lines. The experimental results in Chapter 2 were rationalized, and the hypotheses were verified. In Chapter 4, more experiments were carried out to show solvent dependence, nebulizer optimization, and fragmentation control for the characterization of ESI-MS. Future work was proposed to combine the ion lens with a multiple-spray ion source, where the ion lens has the potential to improve the sensitivity of the ion source, and to simultaneously introduce a mass calibrant to improve the mass accuracy of mass spectrometry.","abstract_html":"The effect of an atmospheric pressure ion lens on electrospray ionization mass spectrometry (ESI-MS) was investigated. In Chapter 2, the voltage combinations applied to the spray and the ion lens were systematically studied, as well as the current-voltage relationship. The ion lens showed its ability to widen the range of operational spray voltages and improve signal intensity. Through the calculations in Chapter 3, the effect ofthe ion lens is demonstrated to include improving the electrospray process by changing the field strength and widening the operational spray voltage range, and increasing the transmission efficiency by focusing ions through the flattened equipotential lines. The experimental results in Chapter 2 were rationalized, and the hypotheses were verified. In Chapter 4, more experiments were carried out to show solvent dependence, nebulizer optimization, and fragmentation control for the characterization of ESI-MS. Future work was proposed to combine the ion lens with a multiple-spray ion source, where the ion lens has the potential to improve the sensitivity of the ion source, and to simultaneously introduce a mass calibrant to improve the mass accuracy of mass spectrometry.","abstract_has_math":false,"creators":["Yi, Rong"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-19T14:35:23Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/16915","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/16915","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/16915/1/ubc_2005-0712.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F16915","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Yi, Rong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/16915","http://circle.library.ubc.ca/bitstream/2429/16915/1/ubc_2005-0712.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The effect of an atmospheric pressure ion lens on electrospray ionization mass spectrometry (ESI-MS) was investigated. In Chapter 2, the voltage combinations applied to the spray and the ion lens were systematically studied, as well as the current-voltage relationship. The ion lens showed its ability to widen the range of operational spray voltages and improve signal intensity. Through the calculations in Chapter 3, the effect ofthe ion lens is demonstrated to include improving the electrospray process by changing the field strength and widening the operational spray voltage range, and increasing the transmission efficiency by focusing ions through the flattened equipotential lines. The experimental results in Chapter 2 were rationalized, and the hypotheses were verified. In Chapter 4, more experiments were carried out to show solvent dependence, nebulizer optimization, and fragmentation control for the characterization of ESI-MS. Future work was proposed to combine the ion lens with a multiple-spray ion source, where the ion lens has the potential to improve the sensitivity of the ion source, and to simultaneously introduce a mass calibrant to improve the mass accuracy of mass spectrometry."]},{"key":"dc:format","label":"Dc Format","values":["13382647","application/pdf"]},{"key":"dc:title","label":"Title","values":["Effect of atmospheric pressure ion lens on an electrospray ion source"]}]}],"canonical_facts":{"dc:creator":["Yi, Rong"],"dc:date":["2005"],"dc:description":["The effect of an atmospheric pressure ion lens on electrospray ionization mass spectrometry (ESI-MS) was investigated. In Chapter 2, the voltage combinations applied to the spray and the ion lens were systematically studied, as well as the current-voltage relationship. The ion lens showed its ability to widen the range of operational spray voltages and improve signal intensity. Through the calculations in Chapter 3, the effect ofthe ion lens is demonstrated to include improving the electrospray process by changing the field strength and widening the operational spray voltage range, and increasing the transmission efficiency by focusing ions through the flattened equipotential lines. The experimental results in Chapter 2 were rationalized, and the hypotheses were verified. In Chapter 4, more experiments were carried out to show solvent dependence, nebulizer optimization, and fragmentation control for the characterization of ESI-MS. Future work was proposed to combine the ion lens with a multiple-spray ion source, where the ion lens has the potential to improve the sensitivity of the ion source, and to simultaneously introduce a mass calibrant to improve the mass accuracy of mass spectrometry."],"dc:format":["13382647","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/16915","http://circle.library.ubc.ca/bitstream/2429/16915/1/ubc_2005-0712.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Effect of atmospheric pressure ion lens on an electrospray ion source"],"dc:type":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:35:23Z"}