{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/17944"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/17944","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Efficiency of single versus multiple stimuli for 40-Hz auditory steady-state responses","abstract":"Auditory steady-state responses (ASSRs) were elicited in normal-hearing, awake adults to 500-, 1000-, 2000-, and 4000-Hz carrier frequencies amplitude-modulated in the 40-Hz range in three conditions: individually [monotic-single(MS)--one carrier], simultaneously in one ear [monotic-multiple(MM)--total four carriers], and simultaneously in both ears [dichotic-multiple(DM)--total eight carriers], at intensities of 30, 55, and 80 dBHL. In general, response amplitudes (collapsed across frequency and intensity) decreased with increasing number of simultaneous stimuli, and were 270, 155, and 107 nV for MS, MM and DM conditions, respectively. Amplitude decreases at 30 dBHL, however, were not significant. Relative efficiency (relative test efficiency of multiple versus single conditions) increased from single- to multiple-stimulus conditions, but there was no significant difference between MM and DM conditions. Mean relative efficiencies were 1.00, 1.38, and 1.39 for MS, MM and DM conditions, respectively. At 80 dBHL, there was no significant increase in relative efficiency with multiple stimuli. These results suggest that 40-Hz ASSRs to low and moderate intensities are most efficiently assessed using monotic-multiple stimuli, and that there may be little advantage to simultaneously stimulating both ears. High intensities might be more efficiently assessed using single stimuli.","abstract_html":"Auditory steady-state responses (ASSRs) were elicited in normal-hearing, awake adults to 500-, 1000-, 2000-, and 4000-Hz carrier frequencies amplitude-modulated in the 40-Hz range in three conditions: individually [monotic-single(MS)--one carrier], simultaneously in one ear [monotic-multiple(MM)--total four carriers], and simultaneously in both ears [dichotic-multiple(DM)--total eight carriers], at intensities of 30, 55, and 80 dBHL. In general, response amplitudes (collapsed across frequency and intensity) decreased with increasing number of simultaneous stimuli, and were 270, 155, and 107 nV for MS, MM and DM conditions, respectively. Amplitude decreases at 30 dBHL, however, were not significant. Relative efficiency (relative test efficiency of multiple versus single conditions) increased from single- to multiple-stimulus conditions, but there was no significant difference between MM and DM conditions. Mean relative efficiencies were 1.00, 1.38, and 1.39 for MS, MM and DM conditions, respectively. At 80 dBHL, there was no significant increase in relative efficiency with multiple stimuli. These results suggest that 40-Hz ASSRs to low and moderate intensities are most efficiently assessed using monotic-multiple stimuli, and that there may be little advantage to simultaneously stimulating both ears. High intensities might be more efficiently assessed using single stimuli.","abstract_has_math":false,"creators":["Fontaine, Charles Maurice"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Audiology and Speech Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-11-19T14:36:08Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/17944","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/17944","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/17944/1/ubc_2006-0454.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F17944","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Fontaine, Charles Maurice"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Audiology and Speech Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/17944","http://circle.library.ubc.ca/bitstream/2429/17944/1/ubc_2006-0454.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Auditory steady-state responses (ASSRs) were elicited in normal-hearing, awake adults to 500-, 1000-, 2000-, and 4000-Hz carrier frequencies amplitude-modulated in the 40-Hz range in three conditions: individually [monotic-single(MS)--one carrier], simultaneously in one ear [monotic-multiple(MM)--total four carriers], and simultaneously in both ears [dichotic-multiple(DM)--total eight carriers], at intensities of 30, 55, and 80 dBHL. In general, response amplitudes (collapsed across frequency and intensity) decreased with increasing number of simultaneous stimuli, and were 270, 155, and 107 nV for MS, MM and DM conditions, respectively. Amplitude decreases at 30 dBHL, however, were not significant. Relative efficiency (relative test efficiency of multiple versus single conditions) increased from single- to multiple-stimulus conditions, but there was no significant difference between MM and DM conditions. Mean relative efficiencies were 1.00, 1.38, and 1.39 for MS, MM and DM conditions, respectively. At 80 dBHL, there was no significant increase in relative efficiency with multiple stimuli. These results suggest that 40-Hz ASSRs to low and moderate intensities are most efficiently assessed using monotic-multiple stimuli, and that there may be little advantage to simultaneously stimulating both ears. High intensities might be more efficiently assessed using single stimuli."]},{"key":"dc:format","label":"Dc Format","values":["3648356","application/pdf"]},{"key":"dc:title","label":"Title","values":["Efficiency of single versus multiple stimuli for 40-Hz auditory steady-state responses"]}]}],"canonical_facts":{"dc:creator":["Fontaine, Charles Maurice"],"dc:date":["2006"],"dc:description":["Auditory steady-state responses (ASSRs) were elicited in normal-hearing, awake adults to 500-, 1000-, 2000-, and 4000-Hz carrier frequencies amplitude-modulated in the 40-Hz range in three conditions: individually [monotic-single(MS)--one carrier], simultaneously in one ear [monotic-multiple(MM)--total four carriers], and simultaneously in both ears [dichotic-multiple(DM)--total eight carriers], at intensities of 30, 55, and 80 dBHL. In general, response amplitudes (collapsed across frequency and intensity) decreased with increasing number of simultaneous stimuli, and were 270, 155, and 107 nV for MS, MM and DM conditions, respectively. Amplitude decreases at 30 dBHL, however, were not significant. Relative efficiency (relative test efficiency of multiple versus single conditions) increased from single- to multiple-stimulus conditions, but there was no significant difference between MM and DM conditions. Mean relative efficiencies were 1.00, 1.38, and 1.39 for MS, MM and DM conditions, respectively. At 80 dBHL, there was no significant increase in relative efficiency with multiple stimuli. These results suggest that 40-Hz ASSRs to low and moderate intensities are most efficiently assessed using monotic-multiple stimuli, and that there may be little advantage to simultaneously stimulating both ears. High intensities might be more efficiently assessed using single stimuli."],"dc:format":["3648356","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/17944","http://circle.library.ubc.ca/bitstream/2429/17944/1/ubc_2006-0454.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Efficiency of single versus multiple stimuli for 40-Hz auditory steady-state responses"],"dc:type":["Text"],"thesis:degree_discipline":["Audiology and Speech Sciences"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:36:08Z"}