{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/19851"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/19851","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Energy measurement of pion beams","abstract":"Pion energies between 30 MeV and 60 MeV have been determined by three methods: magnetic field, range and time of flight. The pion energy was measured to an accuracy 2 # by range and 5 % by the time of flight, and the three methods were consistant with one another. The pions which were used were produced by 500 MeV protons from the TRIUMF cyclotron. The pions were focussed into a beam using the M9 (or stopped π/μ) channel. The bending magnets of this channel define the momentum of the beam particles and thus give one method of determining the pion energy. Differential and integral range curves for aluminum and copper were taken and the differential curves were used to determine the range. In taking the differential curve the effect of stopping plates was examined. In the time of flight method, the leading edge; type discriminator was; found to give; a time walk, due to the different energy-loss; of particles in the plastic scintillator. This has a serious effect in determining the pion energies. However, the constant fraction discriminator was found to give dependable results and the measured energies agreed reasonably well with those of the other methods.","abstract_html":"Pion energies between 30 MeV and 60 MeV have been determined by three methods: magnetic field, range and time of flight. The pion energy was measured to an accuracy 2 # by range and 5 % by the time of flight, and the three methods were consistant with one another. The pions which were used were produced by 500 MeV protons from the TRIUMF cyclotron. The pions were focussed into a beam using the M9 (or stopped π/μ) channel. The bending magnets of this channel define the momentum of the beam particles and thus give one method of determining the pion energy. Differential and integral range curves for aluminum and copper were taken and the differential curves were used to determine the range. In taking the differential curve the effect of stopping plates was examined. In the time of flight method, the leading edge; type discriminator was; found to give; a time walk, due to the different energy-loss; of particles in the plastic scintillator. This has a serious effect in determining the pion energies. However, the constant fraction discriminator was found to give dependable results and the measured energies agreed reasonably well with those of the other methods.","abstract_has_math":false,"creators":["Suzuki, Takenori"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1976,"date_issued":"1976","date_published":"1976","updated_at":"2026-11-19T14:38:15Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/19851","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/19851","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/19851/1/UBC_1976_A6_7+S89.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F19851","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Suzuki, Takenori"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1976"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/19851","http://circle.library.ubc.ca/bitstream/2429/19851/1/UBC_1976_A6_7+S89.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Pion energies between 30 MeV and 60 MeV have been determined by three methods: magnetic field, range and time of flight. The pion energy was measured to an accuracy 2 # by range and 5 % by the time of flight, and the three methods were consistant with one another. The pions which were used were produced by 500 MeV protons from the TRIUMF cyclotron. The pions were focussed into a beam using the M9 (or stopped π/μ) channel. The bending magnets of this channel define the momentum of the beam particles and thus give one method of determining the pion energy. Differential and integral range curves for aluminum and copper were taken and the differential curves were used to determine the range. In taking the differential curve the effect of stopping plates was examined. In the time of flight method, the leading edge; type discriminator was; found to give; a time walk, due to the different energy-loss; of particles in the plastic scintillator. This has a serious effect in determining the pion energies. However, the constant fraction discriminator was found to give dependable results and the measured energies agreed reasonably well with those of the other methods."]},{"key":"dc:format","label":"Dc Format","values":["3306603","application/pdf"]},{"key":"dc:title","label":"Title","values":["Energy measurement of pion beams"]}]}],"canonical_facts":{"dc:creator":["Suzuki, Takenori"],"dc:date":["1976"],"dc:description":["Pion energies between 30 MeV and 60 MeV have been determined by three methods: magnetic field, range and time of flight. The pion energy was measured to an accuracy 2 # by range and 5 % by the time of flight, and the three methods were consistant with one another. The pions which were used were produced by 500 MeV protons from the TRIUMF cyclotron. The pions were focussed into a beam using the M9 (or stopped π/μ) channel. The bending magnets of this channel define the momentum of the beam particles and thus give one method of determining the pion energy. Differential and integral range curves for aluminum and copper were taken and the differential curves were used to determine the range. In taking the differential curve the effect of stopping plates was examined. In the time of flight method, the leading edge; type discriminator was; found to give; a time walk, due to the different energy-loss; of particles in the plastic scintillator. This has a serious effect in determining the pion energies. However, the constant fraction discriminator was found to give dependable results and the measured energies agreed reasonably well with those of the other methods."],"dc:format":["3306603","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/19851","http://circle.library.ubc.ca/bitstream/2429/19851/1/UBC_1976_A6_7+S89.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Energy measurement of pion beams"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:38:15Z"}