{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/20291"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/20291","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A solid state detector head for astronomical applications","abstract":"A detector head for housing self scanned silicon photo-detector arrays has been constructed for use in astronomy. It employs a unique frozen methanol cooling-\"system and, although built specifically for the linear Reticon devices, it is capable of housing other linear or two dimensional monolithic arrays. This detector head is used with a control and data acquisition system that was developed at the University of British Columbia by the Institute of Astronomy and Space Science. A previous detector head, used with the above control system had incorporated a dry ice cooled 256A/17 Reticon array in a housing constructed, specifically for use on an F/1 concentric mirror spectrograph camera. This older device had many problems associated with it which made it difficult to operate and unreliable. With the 256A/17 Reticon mounted in the new camera head these problems have been eliminated. In particular, frosting no longer occurs, dark current has been reduced to a negligible level, and the readout noise has been reduced by a factor of two. As a result of this success, a 1024C/17 Reticon has been substituted for the 256 element array and there are plans for mounting a 100 x100 two dimensional array in this detector head.","abstract_html":"A detector head for housing self scanned silicon photo-detector arrays has been constructed for use in astronomy. It employs a unique frozen methanol cooling-&quot;system and, although built specifically for the linear Reticon devices, it is capable of housing other linear or two dimensional monolithic arrays. This detector head is used with a control and data acquisition system that was developed at the University of British Columbia by the Institute of Astronomy and Space Science. A previous detector head, used with the above control system had incorporated a dry ice cooled 256A/17 Reticon array in a housing constructed, specifically for use on an F/1 concentric mirror spectrograph camera. This older device had many problems associated with it which made it difficult to operate and unreliable. With the 256A/17 Reticon mounted in the new camera head these problems have been eliminated. In particular, frosting no longer occurs, dark current has been reduced to a negligible level, and the readout noise has been reduced by a factor of two. As a result of this success, a 1024C/17 Reticon has been substituted for the 256 element array and there are plans for mounting a 100 x100 two dimensional array in this detector head.","abstract_has_math":false,"creators":["Lester, Timothy Paul"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1977,"date_issued":"1977","date_published":"1977","updated_at":"2026-11-19T14:38:48Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/20291","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/20291","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/20291/1/UBC_1977_A6_7+L48.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F20291","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lester, Timothy Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1977"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Astronomy"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/20291","http://circle.library.ubc.ca/bitstream/2429/20291/1/UBC_1977_A6_7+L48.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A detector head for housing self scanned silicon photo-detector arrays has been constructed for use in astronomy. It employs a unique frozen methanol cooling-\"system and, although built specifically for the linear Reticon devices, it is capable of housing other linear or two dimensional monolithic arrays. This detector head is used with a control and data acquisition system that was developed at the University of British Columbia by the Institute of Astronomy and Space Science. A previous detector head, used with the above control system had incorporated a dry ice cooled 256A/17 Reticon array in a housing constructed, specifically for use on an F/1 concentric mirror spectrograph camera. This older device had many problems associated with it which made it difficult to operate and unreliable. With the 256A/17 Reticon mounted in the new camera head these problems have been eliminated. In particular, frosting no longer occurs, dark current has been reduced to a negligible level, and the readout noise has been reduced by a factor of two. As a result of this success, a 1024C/17 Reticon has been substituted for the 256 element array and there are plans for mounting a 100 x100 two dimensional array in this detector head."]},{"key":"dc:format","label":"Dc Format","values":["6625007","application/pdf"]},{"key":"dc:title","label":"Title","values":["A solid state detector head for astronomical applications"]}]}],"canonical_facts":{"dc:creator":["Lester, Timothy Paul"],"dc:date":["1977"],"dc:description":["A detector head for housing self scanned silicon photo-detector arrays has been constructed for use in astronomy. It employs a unique frozen methanol cooling-\"system and, although built specifically for the linear Reticon devices, it is capable of housing other linear or two dimensional monolithic arrays. This detector head is used with a control and data acquisition system that was developed at the University of British Columbia by the Institute of Astronomy and Space Science. A previous detector head, used with the above control system had incorporated a dry ice cooled 256A/17 Reticon array in a housing constructed, specifically for use on an F/1 concentric mirror spectrograph camera. This older device had many problems associated with it which made it difficult to operate and unreliable. With the 256A/17 Reticon mounted in the new camera head these problems have been eliminated. In particular, frosting no longer occurs, dark current has been reduced to a negligible level, and the readout noise has been reduced by a factor of two. As a result of this success, a 1024C/17 Reticon has been substituted for the 256 element array and there are plans for mounting a 100 x100 two dimensional array in this detector head."],"dc:format":["6625007","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/20291","http://circle.library.ubc.ca/bitstream/2429/20291/1/UBC_1977_A6_7+L48.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A solid state detector head for astronomical applications"],"dc:type":["Text"],"thesis:degree_discipline":["Astronomy"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:38:48Z"}