{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/21582"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/21582","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Plume dispersion and monitor network design","abstract":"Steady-state Gaussian binomial equations are widely used for predicting the dispersion and ground-level concentrations of pollutants emitted from stacks. The equations do not account for varying emissions and meteorological conditions. A pseudo-steady-state model was therefore developed by introducing a propagation time factor into the Gaussian equations. The model was subsequently used to simulate pollutant dispersion in regions with up to four different stacks and with different meteorological conditions. Optimum sites for monitoring ground-level concentrations were selected by maximizing the frequency of measurable concentrations or identifying locations of maximum concentrations. The selection was performed by means of a FORTRAN computer program which can be readily modified to meet different requirements. The program also calculates the conversion rate, i.e. the frequency of time for which the monitors acquires sufficient data to enable determination of pollutant emission rates from the stacks. The program was tested for fifteen different idealized situations and it was also applied to a practical monitor siting problem. The program performed satisfactorily and the results of the various test cases are reported.","abstract_html":"Steady-state Gaussian binomial equations are widely used for predicting the dispersion and ground-level concentrations of pollutants emitted from stacks. The equations do not account for varying emissions and meteorological conditions. A pseudo-steady-state model was therefore developed by introducing a propagation time factor into the Gaussian equations. The model was subsequently used to simulate pollutant dispersion in regions with up to four different stacks and with different meteorological conditions. Optimum sites for monitoring ground-level concentrations were selected by maximizing the frequency of measurable concentrations or identifying locations of maximum concentrations. The selection was performed by means of a FORTRAN computer program which can be readily modified to meet different requirements. The program also calculates the conversion rate, i.e. the frequency of time for which the monitors acquires sufficient data to enable determination of pollutant emission rates from the stacks. The program was tested for fifteen different idealized situations and it was also applied to a practical monitor siting problem. The program performed satisfactorily and the results of the various test cases are reported.","abstract_has_math":false,"creators":["Rowat, David Whitborne"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Chemical and Biological Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1979,"date_issued":"1979","date_published":"1979","updated_at":"2026-11-19T14:39:33Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/21582","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/21582","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/21582/1/UBC_1979_A7+R59.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F21582","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Rowat, David Whitborne"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1979"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/21582","http://circle.library.ubc.ca/bitstream/2429/21582/1/UBC_1979_A7+R59.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Steady-state Gaussian binomial equations are widely used for predicting the dispersion and ground-level concentrations of pollutants emitted from stacks. The equations do not account for varying emissions and meteorological conditions. A pseudo-steady-state model was therefore developed by introducing a propagation time factor into the Gaussian equations. The model was subsequently used to simulate pollutant dispersion in regions with up to four different stacks and with different meteorological conditions. Optimum sites for monitoring ground-level concentrations were selected by maximizing the frequency of measurable concentrations or identifying locations of maximum concentrations. The selection was performed by means of a FORTRAN computer program which can be readily modified to meet different requirements. The program also calculates the conversion rate, i.e. the frequency of time for which the monitors acquires sufficient data to enable determination of pollutant emission rates from the stacks. The program was tested for fifteen different idealized situations and it was also applied to a practical monitor siting problem. The program performed satisfactorily and the results of the various test cases are reported."]},{"key":"dc:format","label":"Dc Format","values":["11372690","application/pdf"]},{"key":"dc:title","label":"Title","values":["Plume dispersion and monitor network design"]}]}],"canonical_facts":{"dc:creator":["Rowat, David Whitborne"],"dc:date":["1979"],"dc:description":["Steady-state Gaussian binomial equations are widely used for predicting the dispersion and ground-level concentrations of pollutants emitted from stacks. The equations do not account for varying emissions and meteorological conditions. A pseudo-steady-state model was therefore developed by introducing a propagation time factor into the Gaussian equations. The model was subsequently used to simulate pollutant dispersion in regions with up to four different stacks and with different meteorological conditions. Optimum sites for monitoring ground-level concentrations were selected by maximizing the frequency of measurable concentrations or identifying locations of maximum concentrations. The selection was performed by means of a FORTRAN computer program which can be readily modified to meet different requirements. The program also calculates the conversion rate, i.e. the frequency of time for which the monitors acquires sufficient data to enable determination of pollutant emission rates from the stacks. The program was tested for fifteen different idealized situations and it was also applied to a practical monitor siting problem. The program performed satisfactorily and the results of the various test cases are reported."],"dc:format":["11372690","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/21582","http://circle.library.ubc.ca/bitstream/2429/21582/1/UBC_1979_A7+R59.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Plume dispersion and monitor network design"],"dc:type":["Text"],"thesis:degree_discipline":["Chemical and Biological Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:39:33Z"}