{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/23414"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/23414","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Characterization of heat transfer in the secondary cooling system of a continuous slab caster","abstract":"Air-purged radiation pyrometers have been installed at several locations below the mould of a continuous slab-casting machine. In each secondary cooling zone, slab surface temperatures have been measured under normal and modified water spray cooling practices. A one-dimensional heat-transfer model of the casting process has been developed, based on the implicit finite-difference method, and used to convert the measured temperature profiles into overall heat-transfer coefficients which incorporate the effects of both the sprays and rolls. Regression equations have been determined for each secondary cooling zone which relate the overall coefficients to the spray water fluxes obtained. The results of this study indicate that unstable film-boiling heat transfer occurs in parts of the secondary cooling system of the machine which was studied. This behaviour results in a large scatter in the spray heat-transfer coefficients and slab surface temperatures. The results also indicate, that current spray cooling practices may exacerbate surface cracking problems. Modifications to the present secondary cooling system are suggested so that better control of slab surface temperatures and better slab quality will be obtained.","abstract_html":"Air-purged radiation pyrometers have been installed at several locations below the mould of a continuous slab-casting machine. In each secondary cooling zone, slab surface temperatures have been measured under normal and modified water spray cooling practices. A one-dimensional heat-transfer model of the casting process has been developed, based on the implicit finite-difference method, and used to convert the measured temperature profiles into overall heat-transfer coefficients which incorporate the effects of both the sprays and rolls. Regression equations have been determined for each secondary cooling zone which relate the overall coefficients to the spray water fluxes obtained. The results of this study indicate that unstable film-boiling heat transfer occurs in parts of the secondary cooling system of the machine which was studied. This behaviour results in a large scatter in the spray heat-transfer coefficients and slab surface temperatures. The results also indicate, that current spray cooling practices may exacerbate surface cracking problems. Modifications to the present secondary cooling system are suggested so that better control of slab surface temperatures and better slab quality will be obtained.","abstract_has_math":false,"creators":["Hibbins, Stephen George"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Materials Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1982,"date_issued":"1982","date_published":"1982","updated_at":"2026-11-19T14:41:29Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/23414","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/23414","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/23414/1/UBC_1982_A7+H53.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F23414","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hibbins, Stephen George"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1982"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/23414","http://circle.library.ubc.ca/bitstream/2429/23414/1/UBC_1982_A7+H53.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Air-purged radiation pyrometers have been installed at several locations below the mould of a continuous slab-casting machine. In each secondary cooling zone, slab surface temperatures have been measured under normal and modified water spray cooling practices. A one-dimensional heat-transfer model of the casting process has been developed, based on the implicit finite-difference method, and used to convert the measured temperature profiles into overall heat-transfer coefficients which incorporate the effects of both the sprays and rolls. Regression equations have been determined for each secondary cooling zone which relate the overall coefficients to the spray water fluxes obtained. The results of this study indicate that unstable film-boiling heat transfer occurs in parts of the secondary cooling system of the machine which was studied. This behaviour results in a large scatter in the spray heat-transfer coefficients and slab surface temperatures. The results also indicate, that current spray cooling practices may exacerbate surface cracking problems. Modifications to the present secondary cooling system are suggested so that better control of slab surface temperatures and better slab quality will be obtained."]},{"key":"dc:format","label":"Dc Format","values":["9571343","application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization of heat transfer in the secondary cooling system of a continuous slab caster"]}]}],"canonical_facts":{"dc:creator":["Hibbins, Stephen George"],"dc:date":["1982"],"dc:description":["Air-purged radiation pyrometers have been installed at several locations below the mould of a continuous slab-casting machine. In each secondary cooling zone, slab surface temperatures have been measured under normal and modified water spray cooling practices. A one-dimensional heat-transfer model of the casting process has been developed, based on the implicit finite-difference method, and used to convert the measured temperature profiles into overall heat-transfer coefficients which incorporate the effects of both the sprays and rolls. Regression equations have been determined for each secondary cooling zone which relate the overall coefficients to the spray water fluxes obtained. The results of this study indicate that unstable film-boiling heat transfer occurs in parts of the secondary cooling system of the machine which was studied. This behaviour results in a large scatter in the spray heat-transfer coefficients and slab surface temperatures. The results also indicate, that current spray cooling practices may exacerbate surface cracking problems. Modifications to the present secondary cooling system are suggested so that better control of slab surface temperatures and better slab quality will be obtained."],"dc:format":["9571343","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/23414","http://circle.library.ubc.ca/bitstream/2429/23414/1/UBC_1982_A7+H53.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Characterization of heat transfer in the secondary cooling system of a continuous slab caster"],"dc:type":["Text"],"thesis:degree_discipline":["Materials Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:41:29Z"}