{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/23815"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/23815","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Concentration of bacterial pathogens using microfluidic dielectrophoresis systems","abstract":"Over the course of human history, people have been always troubled by unpredictable outbreaks of pathogenic bacteria. A rapid, specific and durable diagnostic sensor for detecting pathogens in a timely fashion is essential for identifying unknown infectious diseases and reacting by offering proper patient management and public health involvement without delay. Development of a microfluidic system incorporating interdigitated electrodes for characterizing concentration, purification and differentiation of pathogenic bacteria is presented. Polystyrene microspheres, Salmonella typhimurium, Campylobacter jejuni, Escherichia coli and Mycobacterium smegmatis are trapped by the positive dielectrophoretic force produced by the microelectrodes deposited and arrayed on a glass substrate covered with a PDMS microchannel. Diluted buffer used for producing positive dielectrophoresis for capturing cells is selected after evaluating the viability of the cells suspended in different buffers. Trapping efficiencies of Escherichia coli and Mycobacterium smegmatis are acquired by comparing input concentration and output concentration from plating results. Effective conductivities of both Escherichia coli and Mycobacterium smegmatis are calculated by obtaining optical density measurements corresponding to certain buffers with a range of different conductivity values used for trapping. Separation of a mixture with Escherichia coli and Mycobacterium smegmatis is achieved through the microconcentrator, although the results conflict with the calculated cellular conductivity values. The microfluidic DEP concentrator is shown to be an effective tool for studying and separating bacterial populations, and the results clearly indicate exciting directions for future work.","abstract_html":"Over the course of human history, people have been always troubled by unpredictable outbreaks of pathogenic bacteria. A rapid, specific and durable diagnostic sensor for detecting pathogens in a timely fashion is essential for identifying unknown infectious diseases and reacting by offering proper patient management and public health involvement without delay. Development of a microfluidic system incorporating interdigitated electrodes for characterizing concentration, purification and differentiation of pathogenic bacteria is presented. Polystyrene microspheres, Salmonella typhimurium, Campylobacter jejuni, Escherichia coli and Mycobacterium smegmatis are trapped by the positive dielectrophoretic force produced by the microelectrodes deposited and arrayed on a glass substrate covered with a PDMS microchannel. Diluted buffer used for producing positive dielectrophoresis for capturing cells is selected after evaluating the viability of the cells suspended in different buffers. Trapping efficiencies of Escherichia coli and Mycobacterium smegmatis are acquired by comparing input concentration and output concentration from plating results. Effective conductivities of both Escherichia coli and Mycobacterium smegmatis are calculated by obtaining optical density measurements corresponding to certain buffers with a range of different conductivity values used for trapping. Separation of a mixture with Escherichia coli and Mycobacterium smegmatis is achieved through the microconcentrator, although the results conflict with the calculated cellular conductivity values. The microfluidic DEP concentrator is shown to be an effective tool for studying and separating bacterial populations, and the results clearly indicate exciting directions for future work.","abstract_has_math":false,"creators":["Lin, Tao"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Chemical and Biological Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-19T14:41:48Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/23815","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/23815","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/23815/1/ubc_2010_spring_lin_tao.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F23815","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lin, Tao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/23815","http://circle.library.ubc.ca/bitstream/2429/23815/1/ubc_2010_spring_lin_tao.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Over the course of human history, people have been always troubled by unpredictable outbreaks of pathogenic bacteria. A rapid, specific and durable diagnostic sensor for detecting pathogens in a timely fashion is essential for identifying unknown infectious diseases and reacting by offering proper patient management and public health involvement without delay. Development of a microfluidic system incorporating interdigitated electrodes for characterizing concentration, purification and differentiation of pathogenic bacteria is presented. Polystyrene microspheres, Salmonella typhimurium, Campylobacter jejuni, Escherichia coli and Mycobacterium smegmatis are trapped by the positive dielectrophoretic force produced by the microelectrodes deposited and arrayed on a glass substrate covered with a PDMS microchannel. Diluted buffer used for producing positive dielectrophoresis for capturing cells is selected after evaluating the viability of the cells suspended in different buffers. Trapping efficiencies of Escherichia coli and Mycobacterium smegmatis are acquired by comparing input concentration and output concentration from plating results. Effective conductivities of both Escherichia coli and Mycobacterium smegmatis are calculated by obtaining optical density measurements corresponding to certain buffers with a range of different conductivity values used for trapping. Separation of a mixture with Escherichia coli and Mycobacterium smegmatis is achieved through the microconcentrator, although the results conflict with the calculated cellular conductivity values. The microfluidic DEP concentrator is shown to be an effective tool for studying and separating bacterial populations, and the results clearly indicate exciting directions for future work."]},{"key":"dc:format","label":"Dc Format","values":["3910272","application/pdf"]},{"key":"dc:title","label":"Title","values":["Concentration of bacterial pathogens using microfluidic dielectrophoresis systems"]}]}],"canonical_facts":{"dc:creator":["Lin, Tao"],"dc:date":["2010"],"dc:description":["Over the course of human history, people have been always troubled by unpredictable outbreaks of pathogenic bacteria. A rapid, specific and durable diagnostic sensor for detecting pathogens in a timely fashion is essential for identifying unknown infectious diseases and reacting by offering proper patient management and public health involvement without delay. Development of a microfluidic system incorporating interdigitated electrodes for characterizing concentration, purification and differentiation of pathogenic bacteria is presented. Polystyrene microspheres, Salmonella typhimurium, Campylobacter jejuni, Escherichia coli and Mycobacterium smegmatis are trapped by the positive dielectrophoretic force produced by the microelectrodes deposited and arrayed on a glass substrate covered with a PDMS microchannel. Diluted buffer used for producing positive dielectrophoresis for capturing cells is selected after evaluating the viability of the cells suspended in different buffers. Trapping efficiencies of Escherichia coli and Mycobacterium smegmatis are acquired by comparing input concentration and output concentration from plating results. Effective conductivities of both Escherichia coli and Mycobacterium smegmatis are calculated by obtaining optical density measurements corresponding to certain buffers with a range of different conductivity values used for trapping. Separation of a mixture with Escherichia coli and Mycobacterium smegmatis is achieved through the microconcentrator, although the results conflict with the calculated cellular conductivity values. The microfluidic DEP concentrator is shown to be an effective tool for studying and separating bacterial populations, and the results clearly indicate exciting directions for future work."],"dc:format":["3910272","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/23815","http://circle.library.ubc.ca/bitstream/2429/23815/1/ubc_2010_spring_lin_tao.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Concentration of bacterial pathogens using microfluidic dielectrophoresis systems"],"dc:type":["Text"],"thesis:degree_discipline":["Chemical and Biological Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:41:48Z"}