{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/24051"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/24051","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Experimental investigation of the base storey design of base isolated steel buildings","abstract":"Recent research indicates that base isolation of buildings eliminates or reduces seismic loading to an acceptable level. This paper presents the results of the experimental investigations of various base storey schemes for steel buildings with base isolation. A steel frame was designed and built for the shaking table tests, which were conducted in the Earthquake Simulator Laboratory at the University of British Columbia. The dynamic response of the frame was recorded for each base storey design, fixed base or base isolated. The base isolation system consisted of steel roller bearings with parallel, ductile steel energy absorbers(yield rings). These absorbers limit excessive displacement and absorb energy during severe earthquake excitation. They also provide restraint against wind loads and mild earthquake excitation. The new design of the base storey is aimed at eliminating the blind base storey or double foundation. The experimental tests show ways of better design methods and analytical studies are following to optimize them. Uncoupling of buildings from earthquake ground motion is relatively simple to achieve. However a base isolation system requires a certain restraint against minor horizontal loads such as wind loads which can be accomplished by energy absorbers. A new type of solid state energy absorber was used in the described tests. The newly proposed base storey is substantially different from conventional solutions used by other base isolation systems and results in a less expensive but safe design.","abstract_html":"Recent research indicates that base isolation of buildings eliminates or reduces seismic loading to an acceptable level. This paper presents the results of the experimental investigations of various base storey schemes for steel buildings with base isolation. A steel frame was designed and built for the shaking table tests, which were conducted in the Earthquake Simulator Laboratory at the University of British Columbia. The dynamic response of the frame was recorded for each base storey design, fixed base or base isolated. The base isolation system consisted of steel roller bearings with parallel, ductile steel energy absorbers(yield rings). These absorbers limit excessive displacement and absorb energy during severe earthquake excitation. They also provide restraint against wind loads and mild earthquake excitation. The new design of the base storey is aimed at eliminating the blind base storey or double foundation. The experimental tests show ways of better design methods and analytical studies are following to optimize them. Uncoupling of buildings from earthquake ground motion is relatively simple to achieve. However a base isolation system requires a certain restraint against minor horizontal loads such as wind loads which can be accomplished by energy absorbers. A new type of solid state energy absorber was used in the described tests. The newly proposed base storey is substantially different from conventional solutions used by other base isolation systems and results in a less expensive but safe design.","abstract_has_math":false,"creators":["Barwig, Bill Barron"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1983,"date_issued":"1983","date_published":"1983","updated_at":"2026-11-19T14:41:59Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/24051","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/24051","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/24051/1/UBC_1983_A7+B37.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F24051","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Barwig, Bill Barron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1983"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/24051","http://circle.library.ubc.ca/bitstream/2429/24051/1/UBC_1983_A7+B37.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Recent research indicates that base isolation of buildings eliminates or reduces seismic loading to an acceptable level. This paper presents the results of the experimental investigations of various base storey schemes for steel buildings with base isolation. A steel frame was designed and built for the shaking table tests, which were conducted in the Earthquake Simulator Laboratory at the University of British Columbia. The dynamic response of the frame was recorded for each base storey design, fixed base or base isolated. The base isolation system consisted of steel roller bearings with parallel, ductile steel energy absorbers(yield rings). These absorbers limit excessive displacement and absorb energy during severe earthquake excitation. They also provide restraint against wind loads and mild earthquake excitation. The new design of the base storey is aimed at eliminating the blind base storey or double foundation. The experimental tests show ways of better design methods and analytical studies are following to optimize them. Uncoupling of buildings from earthquake ground motion is relatively simple to achieve. However a base isolation system requires a certain restraint against minor horizontal loads such as wind loads which can be accomplished by energy absorbers. A new type of solid state energy absorber was used in the described tests. The newly proposed base storey is substantially different from conventional solutions used by other base isolation systems and results in a less expensive but safe design."]},{"key":"dc:format","label":"Dc Format","values":["9302123","application/pdf"]},{"key":"dc:title","label":"Title","values":["Experimental investigation of the base storey design of base isolated steel buildings"]}]}],"canonical_facts":{"dc:creator":["Barwig, Bill Barron"],"dc:date":["1983"],"dc:description":["Recent research indicates that base isolation of buildings eliminates or reduces seismic loading to an acceptable level. This paper presents the results of the experimental investigations of various base storey schemes for steel buildings with base isolation. A steel frame was designed and built for the shaking table tests, which were conducted in the Earthquake Simulator Laboratory at the University of British Columbia. The dynamic response of the frame was recorded for each base storey design, fixed base or base isolated. The base isolation system consisted of steel roller bearings with parallel, ductile steel energy absorbers(yield rings). These absorbers limit excessive displacement and absorb energy during severe earthquake excitation. They also provide restraint against wind loads and mild earthquake excitation. The new design of the base storey is aimed at eliminating the blind base storey or double foundation. The experimental tests show ways of better design methods and analytical studies are following to optimize them. Uncoupling of buildings from earthquake ground motion is relatively simple to achieve. However a base isolation system requires a certain restraint against minor horizontal loads such as wind loads which can be accomplished by energy absorbers. A new type of solid state energy absorber was used in the described tests. The newly proposed base storey is substantially different from conventional solutions used by other base isolation systems and results in a less expensive but safe design."],"dc:format":["9302123","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/24051","http://circle.library.ubc.ca/bitstream/2429/24051/1/UBC_1983_A7+B37.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Experimental investigation of the base storey design of base isolated steel buildings"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:41:59Z"}