{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/24093"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/24093","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Cavitation and entrainment in a downcomer entrance","abstract":"Two-phase instabilities have been observed at a downcomer entrance in an experimental rig that drains near-saturated Freon-11 from a vessel. The regimes have been characterized using dimensionless parameters describing the pool depth, downcomer flowrate and the subcooling at the liquid interface in the pool. The two primary mechanisms involved in the instability were entrainment and cavitation. The entrainment regimes observed in this study can be correlated with the previously documented occurrence of air-water incipient drawdown. Drawdown was observed at higher pool depths than expected (for a given flowrate) when vapour bubbles were present at the entrance. Cavitation, the mechanism responsible for bubble formation and growth, has been found to be very susceptible to the presence of nucleation sites and to the amount of subcooling at the pool interface. Severe instability may occur at a flowrate where the local velocity at the entrance is equal to the rise velocity of a particular vapour bubble. Due to the generation of vapour through entrainment and cavitation, bubbles conglomerate at the entrance, with the vapour having no mechanism for escape. Some segregation occurs, with small bubbles discharging downwards and large bubbles rising upwards. Downcomer entrance geometry was varied as an independent parameter. In general, the observed regimes in the re-entrant and sharp-edged geometries were similar. The flow regimes in the rounded geometry were unique due to the effect of the streamlined curvature reducing cavitation at the entrance.","abstract_html":"Two-phase instabilities have been observed at a downcomer entrance in an experimental rig that drains near-saturated Freon-11 from a vessel. The regimes have been characterized using dimensionless parameters describing the pool depth, downcomer flowrate and the subcooling at the liquid interface in the pool. The two primary mechanisms involved in the instability were entrainment and cavitation. The entrainment regimes observed in this study can be correlated with the previously documented occurrence of air-water incipient drawdown. Drawdown was observed at higher pool depths than expected (for a given flowrate) when vapour bubbles were present at the entrance. Cavitation, the mechanism responsible for bubble formation and growth, has been found to be very susceptible to the presence of nucleation sites and to the amount of subcooling at the pool interface. Severe instability may occur at a flowrate where the local velocity at the entrance is equal to the rise velocity of a particular vapour bubble. Due to the generation of vapour through entrainment and cavitation, bubbles conglomerate at the entrance, with the vapour having no mechanism for escape. Some segregation occurs, with small bubbles discharging downwards and large bubbles rising upwards. Downcomer entrance geometry was varied as an independent parameter. In general, the observed regimes in the re-entrant and sharp-edged geometries were similar. The flow regimes in the rounded geometry were unique due to the effect of the streamlined curvature reducing cavitation at the entrance.","abstract_has_math":false,"creators":["Ryan, James Arthur"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1983,"date_issued":"1983","date_published":"1983","updated_at":"2026-11-19T14:42:01Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/24093","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/24093","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/24093/1/UBC_1983_A7+R93.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F24093","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Ryan, James Arthur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1983"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/24093","http://circle.library.ubc.ca/bitstream/2429/24093/1/UBC_1983_A7+R93.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Two-phase instabilities have been observed at a downcomer entrance in an experimental rig that drains near-saturated Freon-11 from a vessel. The regimes have been characterized using dimensionless parameters describing the pool depth, downcomer flowrate and the subcooling at the liquid interface in the pool. The two primary mechanisms involved in the instability were entrainment and cavitation. The entrainment regimes observed in this study can be correlated with the previously documented occurrence of air-water incipient drawdown. Drawdown was observed at higher pool depths than expected (for a given flowrate) when vapour bubbles were present at the entrance. Cavitation, the mechanism responsible for bubble formation and growth, has been found to be very susceptible to the presence of nucleation sites and to the amount of subcooling at the pool interface. Severe instability may occur at a flowrate where the local velocity at the entrance is equal to the rise velocity of a particular vapour bubble. Due to the generation of vapour through entrainment and cavitation, bubbles conglomerate at the entrance, with the vapour having no mechanism for escape. Some segregation occurs, with small bubbles discharging downwards and large bubbles rising upwards. Downcomer entrance geometry was varied as an independent parameter. In general, the observed regimes in the re-entrant and sharp-edged geometries were similar. The flow regimes in the rounded geometry were unique due to the effect of the streamlined curvature reducing cavitation at the entrance."]},{"key":"dc:format","label":"Dc Format","values":["6682791","application/pdf"]},{"key":"dc:title","label":"Title","values":["Cavitation and entrainment in a downcomer entrance"]}]}],"canonical_facts":{"dc:creator":["Ryan, James Arthur"],"dc:date":["1983"],"dc:description":["Two-phase instabilities have been observed at a downcomer entrance in an experimental rig that drains near-saturated Freon-11 from a vessel. The regimes have been characterized using dimensionless parameters describing the pool depth, downcomer flowrate and the subcooling at the liquid interface in the pool. The two primary mechanisms involved in the instability were entrainment and cavitation. The entrainment regimes observed in this study can be correlated with the previously documented occurrence of air-water incipient drawdown. Drawdown was observed at higher pool depths than expected (for a given flowrate) when vapour bubbles were present at the entrance. Cavitation, the mechanism responsible for bubble formation and growth, has been found to be very susceptible to the presence of nucleation sites and to the amount of subcooling at the pool interface. Severe instability may occur at a flowrate where the local velocity at the entrance is equal to the rise velocity of a particular vapour bubble. Due to the generation of vapour through entrainment and cavitation, bubbles conglomerate at the entrance, with the vapour having no mechanism for escape. Some segregation occurs, with small bubbles discharging downwards and large bubbles rising upwards. Downcomer entrance geometry was varied as an independent parameter. In general, the observed regimes in the re-entrant and sharp-edged geometries were similar. The flow regimes in the rounded geometry were unique due to the effect of the streamlined curvature reducing cavitation at the entrance."],"dc:format":["6682791","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/24093","http://circle.library.ubc.ca/bitstream/2429/24093/1/UBC_1983_A7+R93.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Cavitation and entrainment in a downcomer entrance"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:42:01Z"}