{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/24096"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/24096","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Flow regimes and pressure histories during blowdown from a vertical tube","abstract":"A series of blowdown experiments have been performed while discharging either vertically (upwards or downwards) or horizontally in order to compare the effect of body force on transient flow patterns and pressure histories. Tests were done using Freon-114 in a clear polycarbonate pipe 4 m long with a 32 mm I.D. Results, presented in the form of flow regime maps, show that the basic nature of the developing flow in a vertical pipe when discharging upward is different than for the downward discharge case. Both cases are in turn markedly different than for horizontal discharge. Pressure histories were found to fall into two categories: one in which the pressure fell rapidly to near the saturation pressure, then slowly to atmospheric; a second in which transient repressurization to nearly the initial pressure was observed following the initial pressure drop. The second category occurred only in the vertical pipe and could not be satisfactorily explained. Rapid changes in axial pressure gradient, and possible flow reversal, were noted in the repressurization case.","abstract_html":"A series of blowdown experiments have been performed while discharging either vertically (upwards or downwards) or horizontally in order to compare the effect of body force on transient flow patterns and pressure histories. Tests were done using Freon-114 in a clear polycarbonate pipe 4 m long with a 32 mm I.D. Results, presented in the form of flow regime maps, show that the basic nature of the developing flow in a vertical pipe when discharging upward is different than for the downward discharge case. Both cases are in turn markedly different than for horizontal discharge. Pressure histories were found to fall into two categories: one in which the pressure fell rapidly to near the saturation pressure, then slowly to atmospheric; a second in which transient repressurization to nearly the initial pressure was observed following the initial pressure drop. The second category occurred only in the vertical pipe and could not be satisfactorily explained. Rapid changes in axial pressure gradient, and possible flow reversal, were noted in the repressurization case.","abstract_has_math":false,"creators":["Steeves, Alan"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1983,"date_issued":"1983","date_published":"1983","updated_at":"2026-11-19T14:42:01Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/24096","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/24096","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/24096/1/UBC_1983_A7+S84_4.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F24096","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Steeves, Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1983"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/24096","http://circle.library.ubc.ca/bitstream/2429/24096/1/UBC_1983_A7+S84_4.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A series of blowdown experiments have been performed while discharging either vertically (upwards or downwards) or horizontally in order to compare the effect of body force on transient flow patterns and pressure histories. Tests were done using Freon-114 in a clear polycarbonate pipe 4 m long with a 32 mm I.D. Results, presented in the form of flow regime maps, show that the basic nature of the developing flow in a vertical pipe when discharging upward is different than for the downward discharge case. Both cases are in turn markedly different than for horizontal discharge. Pressure histories were found to fall into two categories: one in which the pressure fell rapidly to near the saturation pressure, then slowly to atmospheric; a second in which transient repressurization to nearly the initial pressure was observed following the initial pressure drop. The second category occurred only in the vertical pipe and could not be satisfactorily explained. Rapid changes in axial pressure gradient, and possible flow reversal, were noted in the repressurization case."]},{"key":"dc:format","label":"Dc Format","values":["4244699","application/pdf"]},{"key":"dc:title","label":"Title","values":["Flow regimes and pressure histories during blowdown from a vertical tube"]}]}],"canonical_facts":{"dc:creator":["Steeves, Alan"],"dc:date":["1983"],"dc:description":["A series of blowdown experiments have been performed while discharging either vertically (upwards or downwards) or horizontally in order to compare the effect of body force on transient flow patterns and pressure histories. Tests were done using Freon-114 in a clear polycarbonate pipe 4 m long with a 32 mm I.D. Results, presented in the form of flow regime maps, show that the basic nature of the developing flow in a vertical pipe when discharging upward is different than for the downward discharge case. Both cases are in turn markedly different than for horizontal discharge. Pressure histories were found to fall into two categories: one in which the pressure fell rapidly to near the saturation pressure, then slowly to atmospheric; a second in which transient repressurization to nearly the initial pressure was observed following the initial pressure drop. The second category occurred only in the vertical pipe and could not be satisfactorily explained. Rapid changes in axial pressure gradient, and possible flow reversal, were noted in the repressurization case."],"dc:format":["4244699","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/24096","http://circle.library.ubc.ca/bitstream/2429/24096/1/UBC_1983_A7+S84_4.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Flow regimes and pressure histories during blowdown from a vertical tube"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:42:01Z"}