{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/24914"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/24914","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy","abstract":"The work described in this thesis is divided into two parts: testing and evaluation of some surface coils, and application of the surface coils to in-vivo studies. In particular, the localization properties of surface coils were examined and optimized using the highest performance coil geometry and wire. Application of the surface coil technique to in-vivo studies involved measuring changes in metabolic status of muscle and brain tissue in rats using ³¹P spectroscopy. The properties of surface coils have been studied by evaluating their excitation patterns with ¹H and ³¹P NMR spectroscopy. Surface coils, manufactured in different sizes, geometries, and materials were tested for Q factors, signal-to-noise ratios, and pulse widths required for excitation of the sample. A silver plating on the copper wire used to fabricate the surface coils was found to increase the Q and signal-to-noise of the coil. Examination of the excitation patterns of the surface coils with point samples characterized the B₁ field of the coils as decreasing axially and radially from the coil. Calculations of the magnitude of the B₁ field reveal that its dome-like shape extends to approximately one coil radius above the surface coil. It was found that samples lying outside the domain of this \"sensitive volume\" did not contribute to a spectrum. These data were all correlated and the \"0.9\" silver plated coil was deemed to be the most efficient coil with which to pursue further in-vivo studies. In-vivo ³¹P studies of rat tissues were preceded by in-vitro spectral measurements of various metabolites at physiological concentrations. These standards were used to aid in the identification of resonances in the in-vivo spectra. Metabolic changes such as artificially induced ischemia in muscle, deceased brain, and artificially induced brain dementia were compared with \"normal\" ³¹P spectra of anaesthetized rat tissues. It was found that oxygen deprivation is readily observed with this technique whereas the preparation of brain dementia cannot be diagnosed with ³¹P NMR spectroscopy.","abstract_html":"The work described in this thesis is divided into two parts: testing and evaluation of some surface coils, and application of the surface coils to in-vivo studies. In particular, the localization properties of surface coils were examined and optimized using the highest performance coil geometry and wire. Application of the surface coil technique to in-vivo studies involved measuring changes in metabolic status of muscle and brain tissue in rats using ³¹P spectroscopy. The properties of surface coils have been studied by evaluating their excitation patterns with ¹H and ³¹P NMR spectroscopy. Surface coils, manufactured in different sizes, geometries, and materials were tested for Q factors, signal-to-noise ratios, and pulse widths required for excitation of the sample. A silver plating on the copper wire used to fabricate the surface coils was found to increase the Q and signal-to-noise of the coil. Examination of the excitation patterns of the surface coils with point samples characterized the B₁ field of the coils as decreasing axially and radially from the coil. Calculations of the magnitude of the B₁ field reveal that its dome-like shape extends to approximately one coil radius above the surface coil. It was found that samples lying outside the domain of this &quot;sensitive volume&quot; did not contribute to a spectrum. These data were all correlated and the &quot;0.9&quot; silver plated coil was deemed to be the most efficient coil with which to pursue further in-vivo studies. In-vivo ³¹P studies of rat tissues were preceded by in-vitro spectral measurements of various metabolites at physiological concentrations. These standards were used to aid in the identification of resonances in the in-vivo spectra. Metabolic changes such as artificially induced ischemia in muscle, deceased brain, and artificially induced brain dementia were compared with &quot;normal&quot; ³¹P spectra of anaesthetized rat tissues. It was found that oxygen deprivation is readily observed with this technique whereas the preparation of brain dementia cannot be diagnosed with ³¹P NMR spectroscopy.","abstract_has_math":false,"creators":["Schachter, Joyce"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985","date_published":"1985","updated_at":"2026-11-19T14:42:38Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/24914","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/24914","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/24914/1/UBC_1985_A6_7+S34.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F24914","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Schachter, Joyce"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1985"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/24914","http://circle.library.ubc.ca/bitstream/2429/24914/1/UBC_1985_A6_7+S34.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The work described in this thesis is divided into two parts: testing and evaluation of some surface coils, and application of the surface coils to in-vivo studies. In particular, the localization properties of surface coils were examined and optimized using the highest performance coil geometry and wire. Application of the surface coil technique to in-vivo studies involved measuring changes in metabolic status of muscle and brain tissue in rats using ³¹P spectroscopy. The properties of surface coils have been studied by evaluating their excitation patterns with ¹H and ³¹P NMR spectroscopy. Surface coils, manufactured in different sizes, geometries, and materials were tested for Q factors, signal-to-noise ratios, and pulse widths required for excitation of the sample. A silver plating on the copper wire used to fabricate the surface coils was found to increase the Q and signal-to-noise of the coil. Examination of the excitation patterns of the surface coils with point samples characterized the B₁ field of the coils as decreasing axially and radially from the coil. Calculations of the magnitude of the B₁ field reveal that its dome-like shape extends to approximately one coil radius above the surface coil. It was found that samples lying outside the domain of this \"sensitive volume\" did not contribute to a spectrum. These data were all correlated and the \"0.9\" silver plated coil was deemed to be the most efficient coil with which to pursue further in-vivo studies. In-vivo ³¹P studies of rat tissues were preceded by in-vitro spectral measurements of various metabolites at physiological concentrations. These standards were used to aid in the identification of resonances in the in-vivo spectra. Metabolic changes such as artificially induced ischemia in muscle, deceased brain, and artificially induced brain dementia were compared with \"normal\" ³¹P spectra of anaesthetized rat tissues. It was found that oxygen deprivation is readily observed with this technique whereas the preparation of brain dementia cannot be diagnosed with ³¹P NMR spectroscopy."]},{"key":"dc:format","label":"Dc Format","values":["4498904","application/pdf"]},{"key":"dc:title","label":"Title","values":["Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy"]}]}],"canonical_facts":{"dc:creator":["Schachter, Joyce"],"dc:date":["1985"],"dc:description":["The work described in this thesis is divided into two parts: testing and evaluation of some surface coils, and application of the surface coils to in-vivo studies. In particular, the localization properties of surface coils were examined and optimized using the highest performance coil geometry and wire. Application of the surface coil technique to in-vivo studies involved measuring changes in metabolic status of muscle and brain tissue in rats using ³¹P spectroscopy. The properties of surface coils have been studied by evaluating their excitation patterns with ¹H and ³¹P NMR spectroscopy. Surface coils, manufactured in different sizes, geometries, and materials were tested for Q factors, signal-to-noise ratios, and pulse widths required for excitation of the sample. A silver plating on the copper wire used to fabricate the surface coils was found to increase the Q and signal-to-noise of the coil. Examination of the excitation patterns of the surface coils with point samples characterized the B₁ field of the coils as decreasing axially and radially from the coil. Calculations of the magnitude of the B₁ field reveal that its dome-like shape extends to approximately one coil radius above the surface coil. It was found that samples lying outside the domain of this \"sensitive volume\" did not contribute to a spectrum. These data were all correlated and the \"0.9\" silver plated coil was deemed to be the most efficient coil with which to pursue further in-vivo studies. In-vivo ³¹P studies of rat tissues were preceded by in-vitro spectral measurements of various metabolites at physiological concentrations. These standards were used to aid in the identification of resonances in the in-vivo spectra. Metabolic changes such as artificially induced ischemia in muscle, deceased brain, and artificially induced brain dementia were compared with \"normal\" ³¹P spectra of anaesthetized rat tissues. It was found that oxygen deprivation is readily observed with this technique whereas the preparation of brain dementia cannot be diagnosed with ³¹P NMR spectroscopy."],"dc:format":["4498904","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/24914","http://circle.library.ubc.ca/bitstream/2429/24914/1/UBC_1985_A6_7+S34.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Application of surface coils to in-vivo studies using ³¹P-NMR spectroscopy"],"dc:type":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:42:38Z"}