{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/25115"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/25115","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Stitch weld effect on solar collector efficiency factor","abstract":"The thermal effects of stitch welding the coolant conduits of a water-cooled flat plate solar collector to its absorber plate have been studied. A physical model of the heat transfer process from the plate to the fluid flowing inside the tube has been presented. The heat transfer coefficient based on the difference between bond temperature and fluid bulk mean temperature is an important factor in determining the collector efficiency factor F'. The upper and lower limits of the actual value of F' have been predicted by considering two extreme boundary conditions to which the fluid is subjected. For a thick and conductive tube wall, F' does not depend on spot size and spot spacing, and tends to an upper limit of 0.883. For a thin and non-conductive tube wall, the boundary condition comprises of a series of step changes in both the axial and circumferential directions of the heat flux. In this case, the heat transfer coefficient and hence F' approach their lower limits which are determined by the welding spot configuration. It was also found that F' increases with the following parameters: the spot angle; the percentage of tube length being welded; and the number of spots among which the welding is being distributed. Furthermore, the temperature distribution inside the fluid has also been computed for this case.","abstract_html":"The thermal effects of stitch welding the coolant conduits of a water-cooled flat plate solar collector to its absorber plate have been studied. A physical model of the heat transfer process from the plate to the fluid flowing inside the tube has been presented. The heat transfer coefficient based on the difference between bond temperature and fluid bulk mean temperature is an important factor in determining the collector efficiency factor F&#x27;. The upper and lower limits of the actual value of F&#x27; have been predicted by considering two extreme boundary conditions to which the fluid is subjected. For a thick and conductive tube wall, F&#x27; does not depend on spot size and spot spacing, and tends to an upper limit of 0.883. For a thin and non-conductive tube wall, the boundary condition comprises of a series of step changes in both the axial and circumferential directions of the heat flux. In this case, the heat transfer coefficient and hence F&#x27; approach their lower limits which are determined by the welding spot configuration. It was also found that F&#x27; increases with the following parameters: the spot angle; the percentage of tube length being welded; and the number of spots among which the welding is being distributed. Furthermore, the temperature distribution inside the fluid has also been computed for this case.","abstract_has_math":false,"creators":["Lo, Andy Ka-Ming"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985","date_published":"1985","updated_at":"2026-11-19T14:42:54Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/25115","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/25115","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/25115/1/UBC_1985_A7+L62.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F25115","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Lo, Andy Ka-Ming"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1985"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/25115","http://circle.library.ubc.ca/bitstream/2429/25115/1/UBC_1985_A7+L62.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The thermal effects of stitch welding the coolant conduits of a water-cooled flat plate solar collector to its absorber plate have been studied. A physical model of the heat transfer process from the plate to the fluid flowing inside the tube has been presented. The heat transfer coefficient based on the difference between bond temperature and fluid bulk mean temperature is an important factor in determining the collector efficiency factor F'. The upper and lower limits of the actual value of F' have been predicted by considering two extreme boundary conditions to which the fluid is subjected. For a thick and conductive tube wall, F' does not depend on spot size and spot spacing, and tends to an upper limit of 0.883. For a thin and non-conductive tube wall, the boundary condition comprises of a series of step changes in both the axial and circumferential directions of the heat flux. In this case, the heat transfer coefficient and hence F' approach their lower limits which are determined by the welding spot configuration. It was also found that F' increases with the following parameters: the spot angle; the percentage of tube length being welded; and the number of spots among which the welding is being distributed. Furthermore, the temperature distribution inside the fluid has also been computed for this case."]},{"key":"dc:format","label":"Dc Format","values":["3933426","application/pdf"]},{"key":"dc:title","label":"Title","values":["Stitch weld effect on solar collector efficiency factor"]}]}],"canonical_facts":{"dc:creator":["Lo, Andy Ka-Ming"],"dc:date":["1985"],"dc:description":["The thermal effects of stitch welding the coolant conduits of a water-cooled flat plate solar collector to its absorber plate have been studied. A physical model of the heat transfer process from the plate to the fluid flowing inside the tube has been presented. The heat transfer coefficient based on the difference between bond temperature and fluid bulk mean temperature is an important factor in determining the collector efficiency factor F'. The upper and lower limits of the actual value of F' have been predicted by considering two extreme boundary conditions to which the fluid is subjected. For a thick and conductive tube wall, F' does not depend on spot size and spot spacing, and tends to an upper limit of 0.883. For a thin and non-conductive tube wall, the boundary condition comprises of a series of step changes in both the axial and circumferential directions of the heat flux. In this case, the heat transfer coefficient and hence F' approach their lower limits which are determined by the welding spot configuration. It was also found that F' increases with the following parameters: the spot angle; the percentage of tube length being welded; and the number of spots among which the welding is being distributed. Furthermore, the temperature distribution inside the fluid has also been computed for this case."],"dc:format":["3933426","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/25115","http://circle.library.ubc.ca/bitstream/2429/25115/1/UBC_1985_A7+L62.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Stitch weld effect on solar collector efficiency factor"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:42:54Z"}