{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/25140"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/25140","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A bench scale experimental study of the treatment of milking centre effluent using a sequencing batch reactor","abstract":"Until recently, the management of milking parlour effluent has received very little attention. The wastewater produced by milking operations comprises mainly milk solids and manure and can impose environmental threats to nearby water bodies if not properly treated before disposal. In this study, three bench-scale Sequencing Batch Biological Reactors were used to treat the UBC dairy barn milking centre wastewater. The experiment was designed to investigate the treatment efficiency of the reactors under different operating temperatures and different numbers of cycles employed per unit daily flow (for the same hydraulic retention time). Parameters studied included BOD₅, COD, Total Suspended Solids, NH₃-N, N0₂-NO₃-N and dissolved oxygen uptake. It was concluded that very high and consistent treatment efficiency can be achieved by using a Sequencing Batch Biological Reactor to treat milking centre wastes. Over 90% BOD₅ removal was observed in the room temperature and 30°C reactors. Even in low operating temperatures of 3.7 and 10.5°C, over 70% BOD₅ removal was attained. Removal of the other pollutional parameters studied was similarly excellent. Uncontrolled denitrification also occured to various degrees in all three reactors. It was also concluded that within the range studied in this experiment (4 to 8 cycles per day), changing the number of cycles employed per unit daily flow did not have any significant effect on the treatment efficiency of the reactors.","abstract_html":"Until recently, the management of milking parlour effluent has received very little attention. The wastewater produced by milking operations comprises mainly milk solids and manure and can impose environmental threats to nearby water bodies if not properly treated before disposal. In this study, three bench-scale Sequencing Batch Biological Reactors were used to treat the UBC dairy barn milking centre wastewater. The experiment was designed to investigate the treatment efficiency of the reactors under different operating temperatures and different numbers of cycles employed per unit daily flow (for the same hydraulic retention time). Parameters studied included BOD₅, COD, Total Suspended Solids, NH₃-N, N0₂-NO₃-N and dissolved oxygen uptake. It was concluded that very high and consistent treatment efficiency can be achieved by using a Sequencing Batch Biological Reactor to treat milking centre wastes. Over 90% BOD₅ removal was observed in the room temperature and 30°C reactors. Even in low operating temperatures of 3.7 and 10.5°C, over 70% BOD₅ removal was attained. Removal of the other pollutional parameters studied was similarly excellent. Uncontrolled denitrification also occured to various degrees in all three reactors. It was also concluded that within the range studied in this experiment (4 to 8 cycles per day), changing the number of cycles employed per unit daily flow did not have any significant effect on the treatment efficiency of the reactors.","abstract_has_math":false,"creators":["Tam, James Ping-Cheong"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Chemical and Biological Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985","date_published":"1985","updated_at":"2026-11-19T14:42:54Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/25140","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/25140","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/25140/1/UBC_1985_A7+T35.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F25140","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Tam, James Ping-Cheong"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1985"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/25140","http://circle.library.ubc.ca/bitstream/2429/25140/1/UBC_1985_A7+T35.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Until recently, the management of milking parlour effluent has received very little attention. The wastewater produced by milking operations comprises mainly milk solids and manure and can impose environmental threats to nearby water bodies if not properly treated before disposal. In this study, three bench-scale Sequencing Batch Biological Reactors were used to treat the UBC dairy barn milking centre wastewater. The experiment was designed to investigate the treatment efficiency of the reactors under different operating temperatures and different numbers of cycles employed per unit daily flow (for the same hydraulic retention time). Parameters studied included BOD₅, COD, Total Suspended Solids, NH₃-N, N0₂-NO₃-N and dissolved oxygen uptake. It was concluded that very high and consistent treatment efficiency can be achieved by using a Sequencing Batch Biological Reactor to treat milking centre wastes. Over 90% BOD₅ removal was observed in the room temperature and 30°C reactors. Even in low operating temperatures of 3.7 and 10.5°C, over 70% BOD₅ removal was attained. Removal of the other pollutional parameters studied was similarly excellent. Uncontrolled denitrification also occured to various degrees in all three reactors. It was also concluded that within the range studied in this experiment (4 to 8 cycles per day), changing the number of cycles employed per unit daily flow did not have any significant effect on the treatment efficiency of the reactors."]},{"key":"dc:format","label":"Dc Format","values":["5620409","application/pdf"]},{"key":"dc:title","label":"Title","values":["A bench scale experimental study of the treatment of milking centre effluent using a sequencing batch reactor"]}]}],"canonical_facts":{"dc:creator":["Tam, James Ping-Cheong"],"dc:date":["1985"],"dc:description":["Until recently, the management of milking parlour effluent has received very little attention. The wastewater produced by milking operations comprises mainly milk solids and manure and can impose environmental threats to nearby water bodies if not properly treated before disposal. In this study, three bench-scale Sequencing Batch Biological Reactors were used to treat the UBC dairy barn milking centre wastewater. The experiment was designed to investigate the treatment efficiency of the reactors under different operating temperatures and different numbers of cycles employed per unit daily flow (for the same hydraulic retention time). Parameters studied included BOD₅, COD, Total Suspended Solids, NH₃-N, N0₂-NO₃-N and dissolved oxygen uptake. It was concluded that very high and consistent treatment efficiency can be achieved by using a Sequencing Batch Biological Reactor to treat milking centre wastes. Over 90% BOD₅ removal was observed in the room temperature and 30°C reactors. Even in low operating temperatures of 3.7 and 10.5°C, over 70% BOD₅ removal was attained. Removal of the other pollutional parameters studied was similarly excellent. Uncontrolled denitrification also occured to various degrees in all three reactors. It was also concluded that within the range studied in this experiment (4 to 8 cycles per day), changing the number of cycles employed per unit daily flow did not have any significant effect on the treatment efficiency of the reactors."],"dc:format":["5620409","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/25140","http://circle.library.ubc.ca/bitstream/2429/25140/1/UBC_1985_A7+T35.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A bench scale experimental study of the treatment of milking centre effluent using a sequencing batch reactor"],"dc:type":["Text"],"thesis:degree_discipline":["Chemical and Biological Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:42:54Z"}