{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/25873"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/25873","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"The effect of microwave and convection reheating on the vitamin B₁₂ content of roast beef produced in a cook/freeze foodservice system","abstract":"The purpose of this study was to determine the effect of microwave and convection reheating on the vitamin B₁₂ content of roast beef produced in a cook/freeze foodservice catering system. Two concentrations of vitamin B₁₂ in a phosphate buffer, as well as vitamin B₁₂ found in roast beef, were used throughout this study to detemine the effects of domestic and commercial microwave reheating and convection reheating on vitamin B₁₂. All the vitamin analysis was done using a radioisotope dilution (RID) assay (Bio-Rad Laboratories). In order to study the effects of microwave radiation without heat on vitamin B₁₂, two solutions containing 200 pg/mL and 1500 pg/mL (nominal) were exposed to microwave radiation for time periods of up to one hour in a 625 watt and a 1300 watt microwave oven. The temperature was maintained at 0°C by resting the vials in an ice bath. Retentions ranged from 86.57 ± 3.79 % to 110.29 ± 4.94 %. A fair amount of variability was present in the data, and as a result, the differences in retention were found to be non-significant. The differences between retentions in the two oven types as well as between the two concentrations of the vitamin were also found to be non-significant. Buffer samples were exposed to temperatures of 50°C - 70°C in a 625 watt microwave, a 1300 watt microwave and a convection oven set at 180°C, to detemine the effect of heat on vitamin B₁₂. The destruction of the vitamin was not significant. Retentions ranged from 82.45 ± 3.57 % to 103.3 ± 4.6 %. Non-significant differences were found between the oven types and the two concentrations of the vitamin. Precooked, frozen and thawed roast beef samples were reheated to 70°C in the 2 microwaves and for 30 minutes in the convection oven set at 180°C in order to simulate a hospital cook/freeze catering system. Analysis of the samples indicated that all of the original B₁₂ was present after the samples were reheated. When the meat and drip portions of the samples were analyzed separately, 2.9 - 9.2 % of the vitamin was found in the drip, however, this amount was not significant. The amount of vitamin B₁₂ present in the drip was found to be related to the amount of drip released from the sample. Samples reheated in the 625 watt microwave released significantly less (p< 0.05) drip than samples reheated in either the 1300 watt microwave or the convection oven. The results of these studies suggest that reheating does not appear to have a significant effect on vitamin B₁₂ retention.","abstract_html":"The purpose of this study was to determine the effect of microwave and convection reheating on the vitamin B₁₂ content of roast beef produced in a cook/freeze foodservice catering system. Two concentrations of vitamin B₁₂ in a phosphate buffer, as well as vitamin B₁₂ found in roast beef, were used throughout this study to detemine the effects of domestic and commercial microwave reheating and convection reheating on vitamin B₁₂. All the vitamin analysis was done using a radioisotope dilution (RID) assay (Bio-Rad Laboratories). In order to study the effects of microwave radiation without heat on vitamin B₁₂, two solutions containing 200 pg/mL and 1500 pg/mL (nominal) were exposed to microwave radiation for time periods of up to one hour in a 625 watt and a 1300 watt microwave oven. The temperature was maintained at 0°C by resting the vials in an ice bath. Retentions ranged from 86.57 ± 3.79 % to 110.29 ± 4.94 %. A fair amount of variability was present in the data, and as a result, the differences in retention were found to be non-significant. The differences between retentions in the two oven types as well as between the two concentrations of the vitamin were also found to be non-significant. Buffer samples were exposed to temperatures of 50°C - 70°C in a 625 watt microwave, a 1300 watt microwave and a convection oven set at 180°C, to detemine the effect of heat on vitamin B₁₂. The destruction of the vitamin was not significant. Retentions ranged from 82.45 ± 3.57 % to 103.3 ± 4.6 %. Non-significant differences were found between the oven types and the two concentrations of the vitamin. Precooked, frozen and thawed roast beef samples were reheated to 70°C in the 2 microwaves and for 30 minutes in the convection oven set at 180°C in order to simulate a hospital cook/freeze catering system. Analysis of the samples indicated that all of the original B₁₂ was present after the samples were reheated. When the meat and drip portions of the samples were analyzed separately, 2.9 - 9.2 % of the vitamin was found in the drip, however, this amount was not significant. The amount of vitamin B₁₂ present in the drip was found to be related to the amount of drip released from the sample. Samples reheated in the 625 watt microwave released significantly less (p&lt; 0.05) drip than samples reheated in either the 1300 watt microwave or the convection oven. The results of these studies suggest that reheating does not appear to have a significant effect on vitamin B₁₂ retention.","abstract_has_math":false,"creators":["Gellman, Catherine Elizabeth"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Forestry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986","date_published":"1986","updated_at":"2026-11-19T14:43:30Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/25873","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/25873","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/25873/1/UBC_1986_A6_7+G46.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F25873","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Gellman, Catherine Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1986"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Forestry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/25873","http://circle.library.ubc.ca/bitstream/2429/25873/1/UBC_1986_A6_7+G46.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study was to determine the effect of microwave and convection reheating on the vitamin B₁₂ content of roast beef produced in a cook/freeze foodservice catering system. Two concentrations of vitamin B₁₂ in a phosphate buffer, as well as vitamin B₁₂ found in roast beef, were used throughout this study to detemine the effects of domestic and commercial microwave reheating and convection reheating on vitamin B₁₂. All the vitamin analysis was done using a radioisotope dilution (RID) assay (Bio-Rad Laboratories). In order to study the effects of microwave radiation without heat on vitamin B₁₂, two solutions containing 200 pg/mL and 1500 pg/mL (nominal) were exposed to microwave radiation for time periods of up to one hour in a 625 watt and a 1300 watt microwave oven. The temperature was maintained at 0°C by resting the vials in an ice bath. Retentions ranged from 86.57 ± 3.79 % to 110.29 ± 4.94 %. A fair amount of variability was present in the data, and as a result, the differences in retention were found to be non-significant. The differences between retentions in the two oven types as well as between the two concentrations of the vitamin were also found to be non-significant. Buffer samples were exposed to temperatures of 50°C - 70°C in a 625 watt microwave, a 1300 watt microwave and a convection oven set at 180°C, to detemine the effect of heat on vitamin B₁₂. The destruction of the vitamin was not significant. Retentions ranged from 82.45 ± 3.57 % to 103.3 ± 4.6 %. Non-significant differences were found between the oven types and the two concentrations of the vitamin. Precooked, frozen and thawed roast beef samples were reheated to 70°C in the 2 microwaves and for 30 minutes in the convection oven set at 180°C in order to simulate a hospital cook/freeze catering system. Analysis of the samples indicated that all of the original B₁₂ was present after the samples were reheated. When the meat and drip portions of the samples were analyzed separately, 2.9 - 9.2 % of the vitamin was found in the drip, however, this amount was not significant. The amount of vitamin B₁₂ present in the drip was found to be related to the amount of drip released from the sample. Samples reheated in the 625 watt microwave released significantly less (p< 0.05) drip than samples reheated in either the 1300 watt microwave or the convection oven. The results of these studies suggest that reheating does not appear to have a significant effect on vitamin B₁₂ retention."]},{"key":"dc:format","label":"Dc Format","values":["5502635","application/pdf"]},{"key":"dc:title","label":"Title","values":["The effect of microwave and convection reheating on the vitamin B₁₂ content of roast beef produced in a cook/freeze foodservice system"]}]}],"canonical_facts":{"dc:creator":["Gellman, Catherine Elizabeth"],"dc:date":["1986"],"dc:description":["The purpose of this study was to determine the effect of microwave and convection reheating on the vitamin B₁₂ content of roast beef produced in a cook/freeze foodservice catering system. Two concentrations of vitamin B₁₂ in a phosphate buffer, as well as vitamin B₁₂ found in roast beef, were used throughout this study to detemine the effects of domestic and commercial microwave reheating and convection reheating on vitamin B₁₂. All the vitamin analysis was done using a radioisotope dilution (RID) assay (Bio-Rad Laboratories). In order to study the effects of microwave radiation without heat on vitamin B₁₂, two solutions containing 200 pg/mL and 1500 pg/mL (nominal) were exposed to microwave radiation for time periods of up to one hour in a 625 watt and a 1300 watt microwave oven. The temperature was maintained at 0°C by resting the vials in an ice bath. Retentions ranged from 86.57 ± 3.79 % to 110.29 ± 4.94 %. A fair amount of variability was present in the data, and as a result, the differences in retention were found to be non-significant. The differences between retentions in the two oven types as well as between the two concentrations of the vitamin were also found to be non-significant. Buffer samples were exposed to temperatures of 50°C - 70°C in a 625 watt microwave, a 1300 watt microwave and a convection oven set at 180°C, to detemine the effect of heat on vitamin B₁₂. The destruction of the vitamin was not significant. Retentions ranged from 82.45 ± 3.57 % to 103.3 ± 4.6 %. Non-significant differences were found between the oven types and the two concentrations of the vitamin. Precooked, frozen and thawed roast beef samples were reheated to 70°C in the 2 microwaves and for 30 minutes in the convection oven set at 180°C in order to simulate a hospital cook/freeze catering system. Analysis of the samples indicated that all of the original B₁₂ was present after the samples were reheated. When the meat and drip portions of the samples were analyzed separately, 2.9 - 9.2 % of the vitamin was found in the drip, however, this amount was not significant. The amount of vitamin B₁₂ present in the drip was found to be related to the amount of drip released from the sample. Samples reheated in the 625 watt microwave released significantly less (p< 0.05) drip than samples reheated in either the 1300 watt microwave or the convection oven. The results of these studies suggest that reheating does not appear to have a significant effect on vitamin B₁₂ retention."],"dc:format":["5502635","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/25873","http://circle.library.ubc.ca/bitstream/2429/25873/1/UBC_1986_A6_7+G46.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["The effect of microwave and convection reheating on the vitamin B₁₂ content of roast beef produced in a cook/freeze foodservice system"],"dc:type":["Text"],"thesis:degree_discipline":["Forestry"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:43:30Z"}