{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/26254"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/26254","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer","abstract":"A modular, multiwire drift chamber was built and tested in the M13 area. The resolution obtained with six sense wires, was in the horizontal drift direction σ(mean) < (79.9± .2)µm, with an angular resolution of (9.37±.02)mrads. With the drift chamber mounted in the first wire chamber position of the QQD-spectrometer, this corresponds to a resolution of 1.97mm FWHM at the position of the scattering target. In the vertical direction, using a charge division method, the best achieved resolution was < 2mm FWHM per wire, which gives an angular resolution of 71mrads or 15mm FWHM at the target position. The chamber was run at rates in excess of 10⁶ particles/sec. A multi-chamber system was tested, consisting of two modular four cell drift chambers for the horizontal direction, and one eight cell modular drift chamber, located in between and rotated by 90°, was used for the vertical position determination. The resolution for one four cell chamber was σ(mean) < (108.5± .9)µm, and for the eight cell chamber σ(mean) < (79.9± .2)µm. The angular resolution for this system was 1.37 mrad horizontally and 9.37mrads vertically; in connection with the QQD-spectrometer, this corresponds to FWHM of 0.267mm and 1.12mm respectively at the target spot.","abstract_html":"A modular, multiwire drift chamber was built and tested in the M13 area. The resolution obtained with six sense wires, was in the horizontal drift direction σ(mean) &lt; (79.9± .2)µm, with an angular resolution of (9.37±.02)mrads. With the drift chamber mounted in the first wire chamber position of the QQD-spectrometer, this corresponds to a resolution of 1.97mm FWHM at the position of the scattering target. In the vertical direction, using a charge division method, the best achieved resolution was &lt; 2mm FWHM per wire, which gives an angular resolution of 71mrads or 15mm FWHM at the target position. The chamber was run at rates in excess of 10⁶ particles/sec. A multi-chamber system was tested, consisting of two modular four cell drift chambers for the horizontal direction, and one eight cell modular drift chamber, located in between and rotated by 90°, was used for the vertical position determination. The resolution for one four cell chamber was σ(mean) &lt; (108.5± .9)µm, and for the eight cell chamber σ(mean) &lt; (79.9± .2)µm. The angular resolution for this system was 1.37 mrad horizontally and 9.37mrads vertically; in connection with the QQD-spectrometer, this corresponds to FWHM of 0.267mm and 1.12mm respectively at the target spot.","abstract_has_math":false,"creators":["Forster, Brigitta Monica"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986","date_published":"1986","updated_at":"2026-11-19T14:43:53Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/26254","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/26254","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/26254/1/UBC_1987_A6_7+F67.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F26254","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Forster, Brigitta Monica"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1986"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/26254","http://circle.library.ubc.ca/bitstream/2429/26254/1/UBC_1987_A6_7+F67.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A modular, multiwire drift chamber was built and tested in the M13 area. The resolution obtained with six sense wires, was in the horizontal drift direction σ(mean) < (79.9± .2)µm, with an angular resolution of (9.37±.02)mrads. With the drift chamber mounted in the first wire chamber position of the QQD-spectrometer, this corresponds to a resolution of 1.97mm FWHM at the position of the scattering target. In the vertical direction, using a charge division method, the best achieved resolution was < 2mm FWHM per wire, which gives an angular resolution of 71mrads or 15mm FWHM at the target position. The chamber was run at rates in excess of 10⁶ particles/sec. A multi-chamber system was tested, consisting of two modular four cell drift chambers for the horizontal direction, and one eight cell modular drift chamber, located in between and rotated by 90°, was used for the vertical position determination. The resolution for one four cell chamber was σ(mean) < (108.5± .9)µm, and for the eight cell chamber σ(mean) < (79.9± .2)µm. The angular resolution for this system was 1.37 mrad horizontally and 9.37mrads vertically; in connection with the QQD-spectrometer, this corresponds to FWHM of 0.267mm and 1.12mm respectively at the target spot."]},{"key":"dc:format","label":"Dc Format","values":["4030865","application/pdf"]},{"key":"dc:title","label":"Title","values":["Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer"]}]}],"canonical_facts":{"dc:creator":["Forster, Brigitta Monica"],"dc:date":["1986"],"dc:description":["A modular, multiwire drift chamber was built and tested in the M13 area. The resolution obtained with six sense wires, was in the horizontal drift direction σ(mean) < (79.9± .2)µm, with an angular resolution of (9.37±.02)mrads. With the drift chamber mounted in the first wire chamber position of the QQD-spectrometer, this corresponds to a resolution of 1.97mm FWHM at the position of the scattering target. In the vertical direction, using a charge division method, the best achieved resolution was < 2mm FWHM per wire, which gives an angular resolution of 71mrads or 15mm FWHM at the target position. The chamber was run at rates in excess of 10⁶ particles/sec. A multi-chamber system was tested, consisting of two modular four cell drift chambers for the horizontal direction, and one eight cell modular drift chamber, located in between and rotated by 90°, was used for the vertical position determination. The resolution for one four cell chamber was σ(mean) < (108.5± .9)µm, and for the eight cell chamber σ(mean) < (79.9± .2)µm. The angular resolution for this system was 1.37 mrad horizontally and 9.37mrads vertically; in connection with the QQD-spectrometer, this corresponds to FWHM of 0.267mm and 1.12mm respectively at the target spot."],"dc:format":["4030865","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/26254","http://circle.library.ubc.ca/bitstream/2429/26254/1/UBC_1987_A6_7+F67.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Modular multi-wire drift chambers for the TRIUMF QQD-spectrometer"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:43:53Z"}