{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/26293"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/26293","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A novel phase compensated NMR system","abstract":"A novel continuous-wave (cw) Nuclear Magnetic Resonance (NMR) Q-meter which utilizes phase compensation to force the resonant frequency of the tuned circuit to track the input rf frequency has been developed. This technique eliminates the distortions in the NMR lineshape which characterize conventional systems. A prototype system based upon this principle was constructed and used to measure the enhanced nuclear alignment of a polarized deuteron target. A general theoretical description of the performance of this type of system was developed. The adequacy of this description was tested and verified in the prototype system. Deviations from the theoretical predictions are discussed and the important factors which need be considered in the design of such a system are presented. Deuteron thermal equilibrium NMR lineshapes were measured with a precision of ± 5% using the prototype system. Results have been shown to be reproducible for periods of at least three weeks without the need for any parameter adjustment in the phase compensation system. In addition the tensor polarization results obtained from the NMR data are shown to be in agreement with expectations based upon nuclear scattering data.","abstract_html":"A novel continuous-wave (cw) Nuclear Magnetic Resonance (NMR) Q-meter which utilizes phase compensation to force the resonant frequency of the tuned circuit to track the input rf frequency has been developed. This technique eliminates the distortions in the NMR lineshape which characterize conventional systems. A prototype system based upon this principle was constructed and used to measure the enhanced nuclear alignment of a polarized deuteron target. A general theoretical description of the performance of this type of system was developed. The adequacy of this description was tested and verified in the prototype system. Deviations from the theoretical predictions are discussed and the important factors which need be considered in the design of such a system are presented. Deuteron thermal equilibrium NMR lineshapes were measured with a precision of ± 5% using the prototype system. Results have been shown to be reproducible for periods of at least three weeks without the need for any parameter adjustment in the phase compensation system. In addition the tensor polarization results obtained from the NMR data are shown to be in agreement with expectations based upon nuclear scattering data.","abstract_has_math":false,"creators":["Hayden, Michael Edward"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Engineering Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986","date_published":"1986","updated_at":"2026-11-19T14:43:53Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/26293","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/26293","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/26293/1/UBC_1986_A7+H39.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F26293","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hayden, Michael Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1986"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/26293","http://circle.library.ubc.ca/bitstream/2429/26293/1/UBC_1986_A7+H39.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A novel continuous-wave (cw) Nuclear Magnetic Resonance (NMR) Q-meter which utilizes phase compensation to force the resonant frequency of the tuned circuit to track the input rf frequency has been developed. This technique eliminates the distortions in the NMR lineshape which characterize conventional systems. A prototype system based upon this principle was constructed and used to measure the enhanced nuclear alignment of a polarized deuteron target. A general theoretical description of the performance of this type of system was developed. The adequacy of this description was tested and verified in the prototype system. Deviations from the theoretical predictions are discussed and the important factors which need be considered in the design of such a system are presented. Deuteron thermal equilibrium NMR lineshapes were measured with a precision of ± 5% using the prototype system. Results have been shown to be reproducible for periods of at least three weeks without the need for any parameter adjustment in the phase compensation system. In addition the tensor polarization results obtained from the NMR data are shown to be in agreement with expectations based upon nuclear scattering data."]},{"key":"dc:format","label":"Dc Format","values":["8674939","application/pdf"]},{"key":"dc:title","label":"Title","values":["A novel phase compensated NMR system"]}]}],"canonical_facts":{"dc:creator":["Hayden, Michael Edward"],"dc:date":["1986"],"dc:description":["A novel continuous-wave (cw) Nuclear Magnetic Resonance (NMR) Q-meter which utilizes phase compensation to force the resonant frequency of the tuned circuit to track the input rf frequency has been developed. This technique eliminates the distortions in the NMR lineshape which characterize conventional systems. A prototype system based upon this principle was constructed and used to measure the enhanced nuclear alignment of a polarized deuteron target. A general theoretical description of the performance of this type of system was developed. The adequacy of this description was tested and verified in the prototype system. Deviations from the theoretical predictions are discussed and the important factors which need be considered in the design of such a system are presented. Deuteron thermal equilibrium NMR lineshapes were measured with a precision of ± 5% using the prototype system. Results have been shown to be reproducible for periods of at least three weeks without the need for any parameter adjustment in the phase compensation system. In addition the tensor polarization results obtained from the NMR data are shown to be in agreement with expectations based upon nuclear scattering data."],"dc:format":["8674939","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/26293","http://circle.library.ubc.ca/bitstream/2429/26293/1/UBC_1986_A7+H39.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["A novel phase compensated NMR system"],"dc:type":["Text"],"thesis:degree_discipline":["Engineering Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:43:53Z"}