{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/26319"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/26319","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"RBC treatment of a municipal landfill leachate : a pilot scale evaluation","abstract":"This study evaluated the on-site treatment of a moderately low strength municipal landfill leachate with a Rotating Biological Contactor (RBC), at pilot scale (0.9 m dia.). The leachate generally had COD and NH₃-N concentrations of less than 1000 mg/L and 50 mg/L respectively. A high treatment efficiency for both carbon removal and nitrification was achieved despite variable and intermittent loading conditions. The effluent filtrable BOD₅ was generally less than 10 mg/L and the effluent NH₃-N concentration was usually less than 1.0 mg/L. This effluent quality was achieved at mass loading levels comparable to those for sewage treatment (10.0 g BOD₅/m²*d for carbon removal and 0.8 g NH₃-N/m²*d for nitrification). The results demonstrated that long hydraulic retention times (HRT >4 hrs.) can offset the effects of lower temperatures. Nitrification efficiency in particular was shown to be HRT dependent. Limited heavy metal data indicated that heavy metals were removed at efficiencies and relative affinities comparable to those observed in activated sludge studies. An aside to this study showed that trace organics, some of which are on the EPA priority pollutant list, were present in this leachate and were effectively removed during passage through the RBC.","abstract_html":"This study evaluated the on-site treatment of a moderately low strength municipal landfill leachate with a Rotating Biological Contactor (RBC), at pilot scale (0.9 m dia.). The leachate generally had COD and NH₃-N concentrations of less than 1000 mg/L and 50 mg/L respectively. A high treatment efficiency for both carbon removal and nitrification was achieved despite variable and intermittent loading conditions. The effluent filtrable BOD₅ was generally less than 10 mg/L and the effluent NH₃-N concentration was usually less than 1.0 mg/L. This effluent quality was achieved at mass loading levels comparable to those for sewage treatment (10.0 g BOD₅/m²*d for carbon removal and 0.8 g NH₃-N/m²*d for nitrification). The results demonstrated that long hydraulic retention times (HRT &gt;4 hrs.) can offset the effects of lower temperatures. Nitrification efficiency in particular was shown to be HRT dependent. Limited heavy metal data indicated that heavy metals were removed at efficiencies and relative affinities comparable to those observed in activated sludge studies. An aside to this study showed that trace organics, some of which are on the EPA priority pollutant list, were present in this leachate and were effectively removed during passage through the RBC.","abstract_has_math":false,"creators":["Peddie, Craig Cameron"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986","date_published":"1986","updated_at":"2026-11-19T14:43:55Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/26319","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/26319","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/26319/1/UBC_1986_A7+P32.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F26319","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Peddie, Craig Cameron"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1986"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/26319","http://circle.library.ubc.ca/bitstream/2429/26319/1/UBC_1986_A7+P32.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This study evaluated the on-site treatment of a moderately low strength municipal landfill leachate with a Rotating Biological Contactor (RBC), at pilot scale (0.9 m dia.). The leachate generally had COD and NH₃-N concentrations of less than 1000 mg/L and 50 mg/L respectively. A high treatment efficiency for both carbon removal and nitrification was achieved despite variable and intermittent loading conditions. The effluent filtrable BOD₅ was generally less than 10 mg/L and the effluent NH₃-N concentration was usually less than 1.0 mg/L. This effluent quality was achieved at mass loading levels comparable to those for sewage treatment (10.0 g BOD₅/m²*d for carbon removal and 0.8 g NH₃-N/m²*d for nitrification). The results demonstrated that long hydraulic retention times (HRT >4 hrs.) can offset the effects of lower temperatures. Nitrification efficiency in particular was shown to be HRT dependent. Limited heavy metal data indicated that heavy metals were removed at efficiencies and relative affinities comparable to those observed in activated sludge studies. An aside to this study showed that trace organics, some of which are on the EPA priority pollutant list, were present in this leachate and were effectively removed during passage through the RBC."]},{"key":"dc:format","label":"Dc Format","values":["21756503","application/pdf"]},{"key":"dc:title","label":"Title","values":["RBC treatment of a municipal landfill leachate : a pilot scale evaluation"]}]}],"canonical_facts":{"dc:creator":["Peddie, Craig Cameron"],"dc:date":["1986"],"dc:description":["This study evaluated the on-site treatment of a moderately low strength municipal landfill leachate with a Rotating Biological Contactor (RBC), at pilot scale (0.9 m dia.). The leachate generally had COD and NH₃-N concentrations of less than 1000 mg/L and 50 mg/L respectively. A high treatment efficiency for both carbon removal and nitrification was achieved despite variable and intermittent loading conditions. The effluent filtrable BOD₅ was generally less than 10 mg/L and the effluent NH₃-N concentration was usually less than 1.0 mg/L. This effluent quality was achieved at mass loading levels comparable to those for sewage treatment (10.0 g BOD₅/m²*d for carbon removal and 0.8 g NH₃-N/m²*d for nitrification). The results demonstrated that long hydraulic retention times (HRT >4 hrs.) can offset the effects of lower temperatures. Nitrification efficiency in particular was shown to be HRT dependent. Limited heavy metal data indicated that heavy metals were removed at efficiencies and relative affinities comparable to those observed in activated sludge studies. An aside to this study showed that trace organics, some of which are on the EPA priority pollutant list, were present in this leachate and were effectively removed during passage through the RBC."],"dc:format":["21756503","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/26319","http://circle.library.ubc.ca/bitstream/2429/26319/1/UBC_1986_A7+P32.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["RBC treatment of a municipal landfill leachate : a pilot scale evaluation"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:43:55Z"}