{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/26741"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/26741","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Heat transfer from a circular cylinder subject to an oscillating crossflow as in a stirling engine regenerator","abstract":"An experiment was designed and carried out on the fundamental, but poorly understood problem of oscillating flow past a single, transverse, circular cylinder. This is an approximation of the flow about a single element in a matrix-type regenerator used in Stirling-cycle engines. The experimental rig was designed and built to allow tests to be carried out for the wide range of fluid flow parameters characteristic of various Stirling engines. The influence of these parameters on convective heat transfer rates was measured so the approximate effects of these same parameters on a Stirling engine regenerator could be determined. The main conclusion from the experiment was that average Nusselt numbers, based on test-cylinder diameter and subject to flow conditions similar to those found in Stirling engine regenerators, were 40 to 80% higher than those predicted by a steady flow correlation, for a given Reynolds number. This may be due to the high levels of turbulence generated near the test-cylinder. A secondary conclusion is that the compression and expansion of the working fluid due to a 90 degree phase angle difference between the motion of the pistons raises convective heat transfer rates from the test-cylinder substantially over the 180 degree phase angle, or \"sloshing\" motion case.","abstract_html":"An experiment was designed and carried out on the fundamental, but poorly understood problem of oscillating flow past a single, transverse, circular cylinder. This is an approximation of the flow about a single element in a matrix-type regenerator used in Stirling-cycle engines. The experimental rig was designed and built to allow tests to be carried out for the wide range of fluid flow parameters characteristic of various Stirling engines. The influence of these parameters on convective heat transfer rates was measured so the approximate effects of these same parameters on a Stirling engine regenerator could be determined. The main conclusion from the experiment was that average Nusselt numbers, based on test-cylinder diameter and subject to flow conditions similar to those found in Stirling engine regenerators, were 40 to 80% higher than those predicted by a steady flow correlation, for a given Reynolds number. This may be due to the high levels of turbulence generated near the test-cylinder. A secondary conclusion is that the compression and expansion of the working fluid due to a 90 degree phase angle difference between the motion of the pistons raises convective heat transfer rates from the test-cylinder substantially over the 180 degree phase angle, or &quot;sloshing&quot; motion case.","abstract_has_math":false,"creators":["Stowe, Robert Alan"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1987,"date_issued":"1987","date_published":"1987","updated_at":"2026-11-19T14:44:20Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/26741","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/26741","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/26741/1/UBC_1987_A7+S86.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F26741","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Stowe, Robert Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1987"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/26741","http://circle.library.ubc.ca/bitstream/2429/26741/1/UBC_1987_A7+S86.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An experiment was designed and carried out on the fundamental, but poorly understood problem of oscillating flow past a single, transverse, circular cylinder. This is an approximation of the flow about a single element in a matrix-type regenerator used in Stirling-cycle engines. The experimental rig was designed and built to allow tests to be carried out for the wide range of fluid flow parameters characteristic of various Stirling engines. The influence of these parameters on convective heat transfer rates was measured so the approximate effects of these same parameters on a Stirling engine regenerator could be determined. The main conclusion from the experiment was that average Nusselt numbers, based on test-cylinder diameter and subject to flow conditions similar to those found in Stirling engine regenerators, were 40 to 80% higher than those predicted by a steady flow correlation, for a given Reynolds number. This may be due to the high levels of turbulence generated near the test-cylinder. A secondary conclusion is that the compression and expansion of the working fluid due to a 90 degree phase angle difference between the motion of the pistons raises convective heat transfer rates from the test-cylinder substantially over the 180 degree phase angle, or \"sloshing\" motion case."]},{"key":"dc:format","label":"Dc Format","values":["7663714","application/pdf"]},{"key":"dc:title","label":"Title","values":["Heat transfer from a circular cylinder subject to an oscillating crossflow as in a stirling engine regenerator"]}]}],"canonical_facts":{"dc:creator":["Stowe, Robert Alan"],"dc:date":["1987"],"dc:description":["An experiment was designed and carried out on the fundamental, but poorly understood problem of oscillating flow past a single, transverse, circular cylinder. This is an approximation of the flow about a single element in a matrix-type regenerator used in Stirling-cycle engines. The experimental rig was designed and built to allow tests to be carried out for the wide range of fluid flow parameters characteristic of various Stirling engines. The influence of these parameters on convective heat transfer rates was measured so the approximate effects of these same parameters on a Stirling engine regenerator could be determined. The main conclusion from the experiment was that average Nusselt numbers, based on test-cylinder diameter and subject to flow conditions similar to those found in Stirling engine regenerators, were 40 to 80% higher than those predicted by a steady flow correlation, for a given Reynolds number. This may be due to the high levels of turbulence generated near the test-cylinder. A secondary conclusion is that the compression and expansion of the working fluid due to a 90 degree phase angle difference between the motion of the pistons raises convective heat transfer rates from the test-cylinder substantially over the 180 degree phase angle, or \"sloshing\" motion case."],"dc:format":["7663714","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/26741","http://circle.library.ubc.ca/bitstream/2429/26741/1/UBC_1987_A7+S86.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Heat transfer from a circular cylinder subject to an oscillating crossflow as in a stirling engine regenerator"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:44:20Z"}