{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/26749"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/26749","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Research dilatometer testing in sands and in clayey deposits","abstract":"The development of Marchetti's flat dilatometer, method of testing, changes of Marchetti's (1980,1981) original correlations and Schmertmann's (1982,1983) proposed correlations are briefly described. Factors affecting results of the dilatometer test (DMT) are discussed. In order to improve the understanding of the Marchetti dilatometer test (DMT), an electronic research dilatometer was developed at UBC. The research dilatometer can measure; pore pressure at the center of the membrane, membrane displacement, applied pressure, pushing force and verticality. Test results obtained from the research dilatometer in sand and in clayey deposits at 4 sites in the Lower Mainland of B.C. are presented. Soil parameters interpretated using Marchetti's (1980,1981) and Schmertmann's (1982,1983) correlations are discussed. Comparison is made to other in-situ testing methods such as cone penetration test, vane shear test and pressuremeter test. Based on a better understanding of the DMT, future potential methods of improving or checking the existing correlations are proposed.","abstract_html":"The development of Marchetti&#x27;s flat dilatometer, method of testing, changes of Marchetti&#x27;s (1980,1981) original correlations and Schmertmann&#x27;s (1982,1983) proposed correlations are briefly described. Factors affecting results of the dilatometer test (DMT) are discussed. In order to improve the understanding of the Marchetti dilatometer test (DMT), an electronic research dilatometer was developed at UBC. The research dilatometer can measure; pore pressure at the center of the membrane, membrane displacement, applied pressure, pushing force and verticality. Test results obtained from the research dilatometer in sand and in clayey deposits at 4 sites in the Lower Mainland of B.C. are presented. Soil parameters interpretated using Marchetti&#x27;s (1980,1981) and Schmertmann&#x27;s (1982,1983) correlations are discussed. Comparison is made to other in-situ testing methods such as cone penetration test, vane shear test and pressuremeter test. Based on a better understanding of the DMT, future potential methods of improving or checking the existing correlations are proposed.","abstract_has_math":false,"creators":["Tsang, Clifford Hing-Cheung"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1987,"date_issued":"1987","date_published":"1987","updated_at":"2026-11-19T14:44:20Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/26749","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/26749","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/26749/1/UBC_1987_A7+T75.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F26749","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Tsang, Clifford Hing-Cheung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1987"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/26749","http://circle.library.ubc.ca/bitstream/2429/26749/1/UBC_1987_A7+T75.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The development of Marchetti's flat dilatometer, method of testing, changes of Marchetti's (1980,1981) original correlations and Schmertmann's (1982,1983) proposed correlations are briefly described. Factors affecting results of the dilatometer test (DMT) are discussed. In order to improve the understanding of the Marchetti dilatometer test (DMT), an electronic research dilatometer was developed at UBC. The research dilatometer can measure; pore pressure at the center of the membrane, membrane displacement, applied pressure, pushing force and verticality. Test results obtained from the research dilatometer in sand and in clayey deposits at 4 sites in the Lower Mainland of B.C. are presented. Soil parameters interpretated using Marchetti's (1980,1981) and Schmertmann's (1982,1983) correlations are discussed. Comparison is made to other in-situ testing methods such as cone penetration test, vane shear test and pressuremeter test. Based on a better understanding of the DMT, future potential methods of improving or checking the existing correlations are proposed."]},{"key":"dc:format","label":"Dc Format","values":["11814554","application/pdf"]},{"key":"dc:title","label":"Title","values":["Research dilatometer testing in sands and in clayey deposits"]}]}],"canonical_facts":{"dc:creator":["Tsang, Clifford Hing-Cheung"],"dc:date":["1987"],"dc:description":["The development of Marchetti's flat dilatometer, method of testing, changes of Marchetti's (1980,1981) original correlations and Schmertmann's (1982,1983) proposed correlations are briefly described. Factors affecting results of the dilatometer test (DMT) are discussed. In order to improve the understanding of the Marchetti dilatometer test (DMT), an electronic research dilatometer was developed at UBC. The research dilatometer can measure; pore pressure at the center of the membrane, membrane displacement, applied pressure, pushing force and verticality. Test results obtained from the research dilatometer in sand and in clayey deposits at 4 sites in the Lower Mainland of B.C. are presented. Soil parameters interpretated using Marchetti's (1980,1981) and Schmertmann's (1982,1983) correlations are discussed. Comparison is made to other in-situ testing methods such as cone penetration test, vane shear test and pressuremeter test. Based on a better understanding of the DMT, future potential methods of improving or checking the existing correlations are proposed."],"dc:format":["11814554","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/26749","http://circle.library.ubc.ca/bitstream/2429/26749/1/UBC_1987_A7+T75.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Research dilatometer testing in sands and in clayey deposits"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:44:20Z"}