{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/27475"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/27475","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Effects of organic acids in inductively coupled plasma optical emission spectroscopy","abstract":"The effects of organic acids in an inductively coupled plasma (ICP) have been studied with reference to solvent introduction and plasma excitation conditions. When compared with water, an increase in emission intensity for Mg, Cd, and Zn atom and ion lines is observed when organic acids are present in the sample solution. The presence of organic acids causes an increase in both the efficiency of nebulization and the temperature in the lower region of the central aerosol channel. The feasibility of using a semi-automated flow injection (FI) method to investigate the interference effects of acetic acid over a wide range of analyte and interferent concentration has been studied. This FI-ICP procedure makes use of the concentration gradient formed by the analyte in the FI system. Using this method, a response surface can be constructed quickly and with the preparation of relatively few solutions. The response surface shows the system response (for example, emission intensity) as a function of analyte and interferent concentrations. This FI-ICP procedure can be used to map the interference surface prevalent under any set of experimental conditions.","abstract_html":"The effects of organic acids in an inductively coupled plasma (ICP) have been studied with reference to solvent introduction and plasma excitation conditions. When compared with water, an increase in emission intensity for Mg, Cd, and Zn atom and ion lines is observed when organic acids are present in the sample solution. The presence of organic acids causes an increase in both the efficiency of nebulization and the temperature in the lower region of the central aerosol channel. The feasibility of using a semi-automated flow injection (FI) method to investigate the interference effects of acetic acid over a wide range of analyte and interferent concentration has been studied. This FI-ICP procedure makes use of the concentration gradient formed by the analyte in the FI system. Using this method, a response surface can be constructed quickly and with the preparation of relatively few solutions. The response surface shows the system response (for example, emission intensity) as a function of analyte and interferent concentrations. This FI-ICP procedure can be used to map the interference surface prevalent under any set of experimental conditions.","abstract_has_math":false,"creators":["Hettipathirana, Terrance Dayakantha"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1989,"date_issued":"1989","date_published":"1989","updated_at":"2026-11-19T14:44:44Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/27475","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/27475","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/27475/1/UBC_1989_A6_7+H47.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F27475","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hettipathirana, Terrance Dayakantha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1989"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/27475","http://circle.library.ubc.ca/bitstream/2429/27475/1/UBC_1989_A6_7+H47.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The effects of organic acids in an inductively coupled plasma (ICP) have been studied with reference to solvent introduction and plasma excitation conditions. When compared with water, an increase in emission intensity for Mg, Cd, and Zn atom and ion lines is observed when organic acids are present in the sample solution. The presence of organic acids causes an increase in both the efficiency of nebulization and the temperature in the lower region of the central aerosol channel. The feasibility of using a semi-automated flow injection (FI) method to investigate the interference effects of acetic acid over a wide range of analyte and interferent concentration has been studied. This FI-ICP procedure makes use of the concentration gradient formed by the analyte in the FI system. Using this method, a response surface can be constructed quickly and with the preparation of relatively few solutions. The response surface shows the system response (for example, emission intensity) as a function of analyte and interferent concentrations. This FI-ICP procedure can be used to map the interference surface prevalent under any set of experimental conditions."]},{"key":"dc:format","label":"Dc Format","values":["4830191","application/pdf"]},{"key":"dc:title","label":"Title","values":["Effects of organic acids in inductively coupled plasma optical emission spectroscopy"]}]}],"canonical_facts":{"dc:creator":["Hettipathirana, Terrance Dayakantha"],"dc:date":["1989"],"dc:description":["The effects of organic acids in an inductively coupled plasma (ICP) have been studied with reference to solvent introduction and plasma excitation conditions. When compared with water, an increase in emission intensity for Mg, Cd, and Zn atom and ion lines is observed when organic acids are present in the sample solution. The presence of organic acids causes an increase in both the efficiency of nebulization and the temperature in the lower region of the central aerosol channel. The feasibility of using a semi-automated flow injection (FI) method to investigate the interference effects of acetic acid over a wide range of analyte and interferent concentration has been studied. This FI-ICP procedure makes use of the concentration gradient formed by the analyte in the FI system. Using this method, a response surface can be constructed quickly and with the preparation of relatively few solutions. The response surface shows the system response (for example, emission intensity) as a function of analyte and interferent concentrations. This FI-ICP procedure can be used to map the interference surface prevalent under any set of experimental conditions."],"dc:format":["4830191","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/27475","http://circle.library.ubc.ca/bitstream/2429/27475/1/UBC_1989_A6_7+H47.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Effects of organic acids in inductively coupled plasma optical emission spectroscopy"],"dc:type":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:44:44Z"}