{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/28039"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/28039","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Summertime horizontal and vertical advective carbon dioxide fluxes measured in a closed-canopy Douglas-fir forest on a slope","abstract":"An observational study was conducted during an eight-week period in the summer of 2009 at a forested site in British Columbia (“DF49”) to determine the incidence and magnitude of advective carbon dioxide (CO₂) fluxes. The site is situated in a tall, closed-canopy (zh = 35 m, 1100 stems ha-¹, LAI of 7 m² m-²) Douglas-fir forest on a 5-10o slope. Katabatic flow occurs within the subcanopy during a significant portion of the day, especially during the evening and night. Wind vector and CO₂ concentration measurements were made at heights of 1, 2.6, 8, 20 and 42 m on the main flux tower, while CO₂ concentration measurements were made 73.5 m upslope from the tower at heights of 1, 2.6, 8 and 20 m, creating a two-dimensional transect. Eight thermostated non-differential infrared gas analyzers (IRGAs) were paired using a solenoid valve switching system, creating four differential analyzers. The switching system, combined with a twice-daily polynomial IRGA calibration, enabled measurement of CO₂ concentration differences at the four subcanopy measurement heights to an accuracy of 0.5 μmol mol-¹ (horizontal) and 1 μmol mol-¹ (vertical). The system also recorded semi-continuous CO₂ traces at all sample points. Horizontal advective fluxes, averaged over the main measurement period (August 2 - 25), reached 5 μmol m-² s-¹ at night and 10 μmol m-² s-¹ in the afternoon (a net source to the atmosphere) and -2 μmol m-² s-¹ during the morning (net sink). Vertical advective fluxes averaged around zero during the night, 5 μmol m-² s-¹ during the morning and -5 μmol m-² s-¹ during the afternoon. A cumulative sum of advective flux-corrected net ecosystem exchange (NEE) over the main measurement period (-57 g C m-²) was close to that of the friction velocity-corrected NEE (-60 g C m-²), both predicting less carbon uptake by the Douglas-fir forest than the storage-corrected NEE (-86 g C m-²). Additional CO₂ difference measurements made after the main sampling period along the 73.5-m transect demonstrated that horizontal CO₂ differences increased monotonically down slope (on average) at the 2.6-m height, despite an opposing gradient in manual chamber-measured soil CO₂ effluxes.","abstract_html":"An observational study was conducted during an eight-week period in the summer of 2009 at a forested site in British Columbia (“DF49”) to determine the incidence and magnitude of advective carbon dioxide (CO₂) fluxes. The site is situated in a tall, closed-canopy (zh = 35 m, 1100 stems ha-¹, LAI of 7 m² m-²) Douglas-fir forest on a 5-10o slope. Katabatic flow occurs within the subcanopy during a significant portion of the day, especially during the evening and night. Wind vector and CO₂ concentration measurements were made at heights of 1, 2.6, 8, 20 and 42 m on the main flux tower, while CO₂ concentration measurements were made 73.5 m upslope from the tower at heights of 1, 2.6, 8 and 20 m, creating a two-dimensional transect. Eight thermostated non-differential infrared gas analyzers (IRGAs) were paired using a solenoid valve switching system, creating four differential analyzers. The switching system, combined with a twice-daily polynomial IRGA calibration, enabled measurement of CO₂ concentration differences at the four subcanopy measurement heights to an accuracy of 0.5 μmol mol-¹ (horizontal) and 1 μmol mol-¹ (vertical). The system also recorded semi-continuous CO₂ traces at all sample points. Horizontal advective fluxes, averaged over the main measurement period (August 2 - 25), reached 5 μmol m-² s-¹ at night and 10 μmol m-² s-¹ in the afternoon (a net source to the atmosphere) and -2 μmol m-² s-¹ during the morning (net sink). Vertical advective fluxes averaged around zero during the night, 5 μmol m-² s-¹ during the morning and -5 μmol m-² s-¹ during the afternoon. A cumulative sum of advective flux-corrected net ecosystem exchange (NEE) over the main measurement period (-57 g C m-²) was close to that of the friction velocity-corrected NEE (-60 g C m-²), both predicting less carbon uptake by the Douglas-fir forest than the storage-corrected NEE (-86 g C m-²). Additional CO₂ difference measurements made after the main sampling period along the 73.5-m transect demonstrated that horizontal CO₂ differences increased monotonically down slope (on average) at the 2.6-m height, despite an opposing gradient in manual chamber-measured soil CO₂ effluxes.","abstract_has_math":false,"creators":["Leitch, Adrian"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Atmospheric Science","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-19T14:44:56Z","subjects":[],"languages":["eng"],"rights":["Attribution 3.0 Unported"],"rights_urls":["http://creativecommons.org/licenses/by/3.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/28039","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/28039","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/28039/1/ubc_2010_fall_leitch_adrian.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F28039","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Leitch, Adrian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Atmospheric Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by/3.0/","Attribution 3.0 Unported"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/28039","http://circle.library.ubc.ca/bitstream/2429/28039/1/ubc_2010_fall_leitch_adrian.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An observational study was conducted during an eight-week period in the summer of 2009 at a forested site in British Columbia (“DF49”) to determine the incidence and magnitude of advective carbon dioxide (CO₂) fluxes. The site is situated in a tall, closed-canopy (zh = 35 m, 1100 stems ha-¹, LAI of 7 m² m-²) Douglas-fir forest on a 5-10o slope. Katabatic flow occurs within the subcanopy during a significant portion of the day, especially during the evening and night. Wind vector and CO₂ concentration measurements were made at heights of 1, 2.6, 8, 20 and 42 m on the main flux tower, while CO₂ concentration measurements were made 73.5 m upslope from the tower at heights of 1, 2.6, 8 and 20 m, creating a two-dimensional transect. Eight thermostated non-differential infrared gas analyzers (IRGAs) were paired using a solenoid valve switching system, creating four differential analyzers. The switching system, combined with a twice-daily polynomial IRGA calibration, enabled measurement of CO₂ concentration differences at the four subcanopy measurement heights to an accuracy of 0.5 μmol mol-¹ (horizontal) and 1 μmol mol-¹ (vertical). The system also recorded semi-continuous CO₂ traces at all sample points. Horizontal advective fluxes, averaged over the main measurement period (August 2 - 25), reached 5 μmol m-² s-¹ at night and 10 μmol m-² s-¹ in the afternoon (a net source to the atmosphere) and -2 μmol m-² s-¹ during the morning (net sink). Vertical advective fluxes averaged around zero during the night, 5 μmol m-² s-¹ during the morning and -5 μmol m-² s-¹ during the afternoon. A cumulative sum of advective flux-corrected net ecosystem exchange (NEE) over the main measurement period (-57 g C m-²) was close to that of the friction velocity-corrected NEE (-60 g C m-²), both predicting less carbon uptake by the Douglas-fir forest than the storage-corrected NEE (-86 g C m-²). Additional CO₂ difference measurements made after the main sampling period along the 73.5-m transect demonstrated that horizontal CO₂ differences increased monotonically down slope (on average) at the 2.6-m height, despite an opposing gradient in manual chamber-measured soil CO₂ effluxes."]},{"key":"dc:format","label":"Dc Format","values":["3716476","application/pdf"]},{"key":"dc:title","label":"Title","values":["Summertime horizontal and vertical advective carbon dioxide fluxes measured in a closed-canopy Douglas-fir forest on a slope"]}]}],"canonical_facts":{"dc:creator":["Leitch, Adrian"],"dc:date":["2010"],"dc:description":["An observational study was conducted during an eight-week period in the summer of 2009 at a forested site in British Columbia (“DF49”) to determine the incidence and magnitude of advective carbon dioxide (CO₂) fluxes. The site is situated in a tall, closed-canopy (zh = 35 m, 1100 stems ha-¹, LAI of 7 m² m-²) Douglas-fir forest on a 5-10o slope. Katabatic flow occurs within the subcanopy during a significant portion of the day, especially during the evening and night. Wind vector and CO₂ concentration measurements were made at heights of 1, 2.6, 8, 20 and 42 m on the main flux tower, while CO₂ concentration measurements were made 73.5 m upslope from the tower at heights of 1, 2.6, 8 and 20 m, creating a two-dimensional transect. Eight thermostated non-differential infrared gas analyzers (IRGAs) were paired using a solenoid valve switching system, creating four differential analyzers. The switching system, combined with a twice-daily polynomial IRGA calibration, enabled measurement of CO₂ concentration differences at the four subcanopy measurement heights to an accuracy of 0.5 μmol mol-¹ (horizontal) and 1 μmol mol-¹ (vertical). The system also recorded semi-continuous CO₂ traces at all sample points. Horizontal advective fluxes, averaged over the main measurement period (August 2 - 25), reached 5 μmol m-² s-¹ at night and 10 μmol m-² s-¹ in the afternoon (a net source to the atmosphere) and -2 μmol m-² s-¹ during the morning (net sink). Vertical advective fluxes averaged around zero during the night, 5 μmol m-² s-¹ during the morning and -5 μmol m-² s-¹ during the afternoon. A cumulative sum of advective flux-corrected net ecosystem exchange (NEE) over the main measurement period (-57 g C m-²) was close to that of the friction velocity-corrected NEE (-60 g C m-²), both predicting less carbon uptake by the Douglas-fir forest than the storage-corrected NEE (-86 g C m-²). Additional CO₂ difference measurements made after the main sampling period along the 73.5-m transect demonstrated that horizontal CO₂ differences increased monotonically down slope (on average) at the 2.6-m height, despite an opposing gradient in manual chamber-measured soil CO₂ effluxes."],"dc:format":["3716476","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/28039","http://circle.library.ubc.ca/bitstream/2429/28039/1/ubc_2010_fall_leitch_adrian.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by/3.0/","Attribution 3.0 Unported"],"dc:title":["Summertime horizontal and vertical advective carbon dioxide fluxes measured in a closed-canopy Douglas-fir forest on a slope"],"dc:type":["Text"],"thesis:degree_discipline":["Atmospheric Science"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:44:56Z"}