{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/28381"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/28381","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Respiration induced oxygen gradients in cultured mammalian cells","abstract":"Oxygen is known to sensitize X-irradiated cells to lethal radiation damage. At low ambient oxygen tensions, however, the molecular mechanisms of the sensitization process and the metabolic requirements of the cell may be forced to compete for the cellular oxygen supply. The effect of cell respiration on the availability of intracellular oxygen during irradiation was consequently investigated by comparing the radiosensitivities of respiring and non-respiring cells. Cultured mammalian cells were irradiated in single cell suspensions and thin film monolayers at respiration inhibiting (4°C) and at normal cell culturing (37°C) temperatures. Due to oxygen equilibration and radiolytic depletion problems, the results of the suspension culture experiments were inconclusive. By subsequently analyzing the diffusive mass transfer of oxygen in the suspension medium, the stirrer flask was determined to be an inappropriate culture vessel in which to irradiate cells at constant low oxygen concentrations. A thin film cell culture system in which the oxygen concentrations to which the cells were exposed during irradiation could be more accurately controlled was then developed. A comparison of the oxygen enhanced radiosensitivities of the respiring and non-respiring cells in thin film monolayers suggested that the metabolic depletion of oxygen at low oxygen tensions has a significant effect on the local and intracellular oxygen distribution. These effects are representative of those that would be produced if respiration induced oxygen gradients existed inside and immediately around respiring cells. The magnitude of the differential radiosensitivities was found to be dependent on cell shape and to have values that agreed very well with theoretical predictions based on the existence of such gradients.","abstract_html":"Oxygen is known to sensitize X-irradiated cells to lethal radiation damage. At low ambient oxygen tensions, however, the molecular mechanisms of the sensitization process and the metabolic requirements of the cell may be forced to compete for the cellular oxygen supply. The effect of cell respiration on the availability of intracellular oxygen during irradiation was consequently investigated by comparing the radiosensitivities of respiring and non-respiring cells. Cultured mammalian cells were irradiated in single cell suspensions and thin film monolayers at respiration inhibiting (4°C) and at normal cell culturing (37°C) temperatures. Due to oxygen equilibration and radiolytic depletion problems, the results of the suspension culture experiments were inconclusive. By subsequently analyzing the diffusive mass transfer of oxygen in the suspension medium, the stirrer flask was determined to be an inappropriate culture vessel in which to irradiate cells at constant low oxygen concentrations. A thin film cell culture system in which the oxygen concentrations to which the cells were exposed during irradiation could be more accurately controlled was then developed. A comparison of the oxygen enhanced radiosensitivities of the respiring and non-respiring cells in thin film monolayers suggested that the metabolic depletion of oxygen at low oxygen tensions has a significant effect on the local and intracellular oxygen distribution. These effects are representative of those that would be produced if respiration induced oxygen gradients existed inside and immediately around respiring cells. The magnitude of the differential radiosensitivities was found to be dependent on cell shape and to have values that agreed very well with theoretical predictions based on the existence of such gradients.","abstract_has_math":false,"creators":["Fengler, John Josef Paul"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988","date_published":"1988","updated_at":"2026-11-19T14:45:04Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/28381","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/28381","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/28381/1/UBC_1988_A7+F46.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F28381","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Fengler, John Josef Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1988"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/28381","http://circle.library.ubc.ca/bitstream/2429/28381/1/UBC_1988_A7+F46.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Oxygen is known to sensitize X-irradiated cells to lethal radiation damage. At low ambient oxygen tensions, however, the molecular mechanisms of the sensitization process and the metabolic requirements of the cell may be forced to compete for the cellular oxygen supply. The effect of cell respiration on the availability of intracellular oxygen during irradiation was consequently investigated by comparing the radiosensitivities of respiring and non-respiring cells. Cultured mammalian cells were irradiated in single cell suspensions and thin film monolayers at respiration inhibiting (4°C) and at normal cell culturing (37°C) temperatures. Due to oxygen equilibration and radiolytic depletion problems, the results of the suspension culture experiments were inconclusive. By subsequently analyzing the diffusive mass transfer of oxygen in the suspension medium, the stirrer flask was determined to be an inappropriate culture vessel in which to irradiate cells at constant low oxygen concentrations. A thin film cell culture system in which the oxygen concentrations to which the cells were exposed during irradiation could be more accurately controlled was then developed. A comparison of the oxygen enhanced radiosensitivities of the respiring and non-respiring cells in thin film monolayers suggested that the metabolic depletion of oxygen at low oxygen tensions has a significant effect on the local and intracellular oxygen distribution. These effects are representative of those that would be produced if respiration induced oxygen gradients existed inside and immediately around respiring cells. The magnitude of the differential radiosensitivities was found to be dependent on cell shape and to have values that agreed very well with theoretical predictions based on the existence of such gradients."]},{"key":"dc:format","label":"Dc Format","values":["6006656","application/pdf"]},{"key":"dc:title","label":"Title","values":["Respiration induced oxygen gradients in cultured mammalian cells"]}]}],"canonical_facts":{"dc:creator":["Fengler, John Josef Paul"],"dc:date":["1988"],"dc:description":["Oxygen is known to sensitize X-irradiated cells to lethal radiation damage. At low ambient oxygen tensions, however, the molecular mechanisms of the sensitization process and the metabolic requirements of the cell may be forced to compete for the cellular oxygen supply. The effect of cell respiration on the availability of intracellular oxygen during irradiation was consequently investigated by comparing the radiosensitivities of respiring and non-respiring cells. Cultured mammalian cells were irradiated in single cell suspensions and thin film monolayers at respiration inhibiting (4°C) and at normal cell culturing (37°C) temperatures. Due to oxygen equilibration and radiolytic depletion problems, the results of the suspension culture experiments were inconclusive. By subsequently analyzing the diffusive mass transfer of oxygen in the suspension medium, the stirrer flask was determined to be an inappropriate culture vessel in which to irradiate cells at constant low oxygen concentrations. A thin film cell culture system in which the oxygen concentrations to which the cells were exposed during irradiation could be more accurately controlled was then developed. A comparison of the oxygen enhanced radiosensitivities of the respiring and non-respiring cells in thin film monolayers suggested that the metabolic depletion of oxygen at low oxygen tensions has a significant effect on the local and intracellular oxygen distribution. These effects are representative of those that would be produced if respiration induced oxygen gradients existed inside and immediately around respiring cells. The magnitude of the differential radiosensitivities was found to be dependent on cell shape and to have values that agreed very well with theoretical predictions based on the existence of such gradients."],"dc:format":["6006656","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/28381","http://circle.library.ubc.ca/bitstream/2429/28381/1/UBC_1988_A7+F46.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Respiration induced oxygen gradients in cultured mammalian cells"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:45:04Z"}