{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/28492"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/28492","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Analytic three dimensional image reconstruction from projections","abstract":"This work presents an analytic three dimensional image reconstruction algorithm that was developed for a proposed volume-imaging PET scanner. The development of the algorithm was motivated by the scanner's ability to collect an order of magnitude more data than current PET systems and the lack of an efficient algorithm that could use the extra data. The algorithm is based on an extension of the Recovery Operator of Orlov[68] and operates by convolution in object space. This method of operation sets it apart from other analytic direct image reconstruction algorithms that rely on Fourier transforms. The algorithm is tested with ideal data and parameters that are appropriate to the new PET scanner. The results of the test show that the algorithm behaves as expected except for a 17% overshoot in the reconstructed value in one area. An explanation of this artifact is suggested, although not verified. Finally, the efficacy of the algorithm is demonstrated by proving that it is functionally equivalent to Fourier transform methods.","abstract_html":"This work presents an analytic three dimensional image reconstruction algorithm that was developed for a proposed volume-imaging PET scanner. The development of the algorithm was motivated by the scanner&#x27;s ability to collect an order of magnitude more data than current PET systems and the lack of an efficient algorithm that could use the extra data. The algorithm is based on an extension of the Recovery Operator of Orlov[68] and operates by convolution in object space. This method of operation sets it apart from other analytic direct image reconstruction algorithms that rely on Fourier transforms. The algorithm is tested with ideal data and parameters that are appropriate to the new PET scanner. The results of the test show that the algorithm behaves as expected except for a 17% overshoot in the reconstructed value in one area. An explanation of this artifact is suggested, although not verified. Finally, the efficacy of the algorithm is demonstrated by proving that it is functionally equivalent to Fourier transform methods.","abstract_has_math":false,"creators":["Kinahan, Paul Eugene"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1988,"date_issued":"1988","date_published":"1988","updated_at":"2026-11-19T14:45:07Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/28492","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/28492","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/28492/1/UBC_1988_A7+K56.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F28492","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kinahan, Paul Eugene"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1988"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/28492","http://circle.library.ubc.ca/bitstream/2429/28492/1/UBC_1988_A7+K56.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This work presents an analytic three dimensional image reconstruction algorithm that was developed for a proposed volume-imaging PET scanner. The development of the algorithm was motivated by the scanner's ability to collect an order of magnitude more data than current PET systems and the lack of an efficient algorithm that could use the extra data. The algorithm is based on an extension of the Recovery Operator of Orlov[68] and operates by convolution in object space. This method of operation sets it apart from other analytic direct image reconstruction algorithms that rely on Fourier transforms. The algorithm is tested with ideal data and parameters that are appropriate to the new PET scanner. The results of the test show that the algorithm behaves as expected except for a 17% overshoot in the reconstructed value in one area. An explanation of this artifact is suggested, although not verified. Finally, the efficacy of the algorithm is demonstrated by proving that it is functionally equivalent to Fourier transform methods."]},{"key":"dc:format","label":"Dc Format","values":["5746674","application/pdf"]},{"key":"dc:title","label":"Title","values":["Analytic three dimensional image reconstruction from projections"]}]}],"canonical_facts":{"dc:creator":["Kinahan, Paul Eugene"],"dc:date":["1988"],"dc:description":["This work presents an analytic three dimensional image reconstruction algorithm that was developed for a proposed volume-imaging PET scanner. The development of the algorithm was motivated by the scanner's ability to collect an order of magnitude more data than current PET systems and the lack of an efficient algorithm that could use the extra data. The algorithm is based on an extension of the Recovery Operator of Orlov[68] and operates by convolution in object space. This method of operation sets it apart from other analytic direct image reconstruction algorithms that rely on Fourier transforms. The algorithm is tested with ideal data and parameters that are appropriate to the new PET scanner. The results of the test show that the algorithm behaves as expected except for a 17% overshoot in the reconstructed value in one area. An explanation of this artifact is suggested, although not verified. Finally, the efficacy of the algorithm is demonstrated by proving that it is functionally equivalent to Fourier transform methods."],"dc:format":["5746674","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/28492","http://circle.library.ubc.ca/bitstream/2429/28492/1/UBC_1988_A7+K56.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Analytic three dimensional image reconstruction from projections"],"dc:type":["Text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:45:07Z"}