{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/29863"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/29863","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"An evaluation of user performance with inductive coupling of hearing aids and telephone receivers incorporating receiver amplification","abstract":"Previous research has shown the benefit obtained by hard of hearing people when using inductive means (T-switch) to couple their hearing aids to telephone receivers. Benefit provided by receiver amplification in the telephone handset has also been shown. Informal surveys of hard of hearing people indicate that many of them use telephones having a dual capability: magnetic coupling and receiver amplification. The objective of this investigation was to study user performance with this dual capability. In particular, the effect of receiver amplification on the speech perception ability (as measured by R-SPIN test items) of 10 hard of hearing subjects using inductive means to couple their hearing aid to a telephone receiver was examined under both good and poor telephone line conditions. The influence of the predictability of the speech material presented was also investigated by noting any difference between the subjects' performance on high predictability items and performance on low predictability items (of the R-SPIN test). Results showed that the use of receiver amplification in conjunction with inductive coupling significantly improved the subjects' speech perception scores. Not surprisingly, good telephone line conditions also significantly improved the subjects' scores. Improvement due to receiver amplification was noted, irrespective of line conditions. Similarly, improvement due to good line conditions was observed, irrespective of whether amplification was used or not. Both receiver amplification and good line conditions had significant and positive effects on both low predictability and high predictability scores. We conclude that with speech either in or out of context, receiver amplification will be of benefit to those who use inductive coupling. Clinical implications and recommendations are discussed.","abstract_html":"Previous research has shown the benefit obtained by hard of hearing people when using inductive means (T-switch) to couple their hearing aids to telephone receivers. Benefit provided by receiver amplification in the telephone handset has also been shown. Informal surveys of hard of hearing people indicate that many of them use telephones having a dual capability: magnetic coupling and receiver amplification. The objective of this investigation was to study user performance with this dual capability. In particular, the effect of receiver amplification on the speech perception ability (as measured by R-SPIN test items) of 10 hard of hearing subjects using inductive means to couple their hearing aid to a telephone receiver was examined under both good and poor telephone line conditions. The influence of the predictability of the speech material presented was also investigated by noting any difference between the subjects&#x27; performance on high predictability items and performance on low predictability items (of the R-SPIN test). Results showed that the use of receiver amplification in conjunction with inductive coupling significantly improved the subjects&#x27; speech perception scores. Not surprisingly, good telephone line conditions also significantly improved the subjects&#x27; scores. Improvement due to receiver amplification was noted, irrespective of line conditions. Similarly, improvement due to good line conditions was observed, irrespective of whether amplification was used or not. Both receiver amplification and good line conditions had significant and positive effects on both low predictability and high predictability scores. We conclude that with speech either in or out of context, receiver amplification will be of benefit to those who use inductive coupling. Clinical implications and recommendations are discussed.","abstract_has_math":false,"creators":["Hanusaik, Linda Irene"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Audiology and Speech Sciences","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-11-19T14:45:59Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/29863","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/29863","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/29863/1/UBC_1991_A6_7+H36.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F29863","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hanusaik, Linda Irene"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1991"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Audiology and Speech Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/29863","http://circle.library.ubc.ca/bitstream/2429/29863/1/UBC_1991_A6_7+H36.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Previous research has shown the benefit obtained by hard of hearing people when using inductive means (T-switch) to couple their hearing aids to telephone receivers. Benefit provided by receiver amplification in the telephone handset has also been shown. Informal surveys of hard of hearing people indicate that many of them use telephones having a dual capability: magnetic coupling and receiver amplification. The objective of this investigation was to study user performance with this dual capability. In particular, the effect of receiver amplification on the speech perception ability (as measured by R-SPIN test items) of 10 hard of hearing subjects using inductive means to couple their hearing aid to a telephone receiver was examined under both good and poor telephone line conditions. The influence of the predictability of the speech material presented was also investigated by noting any difference between the subjects' performance on high predictability items and performance on low predictability items (of the R-SPIN test). Results showed that the use of receiver amplification in conjunction with inductive coupling significantly improved the subjects' speech perception scores. Not surprisingly, good telephone line conditions also significantly improved the subjects' scores. Improvement due to receiver amplification was noted, irrespective of line conditions. Similarly, improvement due to good line conditions was observed, irrespective of whether amplification was used or not. Both receiver amplification and good line conditions had significant and positive effects on both low predictability and high predictability scores. We conclude that with speech either in or out of context, receiver amplification will be of benefit to those who use inductive coupling. Clinical implications and recommendations are discussed."]},{"key":"dc:format","label":"Dc Format","values":["5298731","application/pdf"]},{"key":"dc:title","label":"Title","values":["An evaluation of user performance with inductive coupling of hearing aids and telephone receivers incorporating receiver amplification"]}]}],"canonical_facts":{"dc:creator":["Hanusaik, Linda Irene"],"dc:date":["1991"],"dc:description":["Previous research has shown the benefit obtained by hard of hearing people when using inductive means (T-switch) to couple their hearing aids to telephone receivers. Benefit provided by receiver amplification in the telephone handset has also been shown. Informal surveys of hard of hearing people indicate that many of them use telephones having a dual capability: magnetic coupling and receiver amplification. The objective of this investigation was to study user performance with this dual capability. In particular, the effect of receiver amplification on the speech perception ability (as measured by R-SPIN test items) of 10 hard of hearing subjects using inductive means to couple their hearing aid to a telephone receiver was examined under both good and poor telephone line conditions. The influence of the predictability of the speech material presented was also investigated by noting any difference between the subjects' performance on high predictability items and performance on low predictability items (of the R-SPIN test). Results showed that the use of receiver amplification in conjunction with inductive coupling significantly improved the subjects' speech perception scores. Not surprisingly, good telephone line conditions also significantly improved the subjects' scores. Improvement due to receiver amplification was noted, irrespective of line conditions. Similarly, improvement due to good line conditions was observed, irrespective of whether amplification was used or not. Both receiver amplification and good line conditions had significant and positive effects on both low predictability and high predictability scores. We conclude that with speech either in or out of context, receiver amplification will be of benefit to those who use inductive coupling. Clinical implications and recommendations are discussed."],"dc:format":["5298731","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/29863","http://circle.library.ubc.ca/bitstream/2429/29863/1/UBC_1991_A6_7+H36.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["An evaluation of user performance with inductive coupling of hearing aids and telephone receivers incorporating receiver amplification"],"dc:type":["Text"],"thesis:degree_discipline":["Audiology and Speech Sciences"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:45:59Z"}