{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/31119"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/31119","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Calculation of frequency-dependent parameters of underground power cables with finite element method","abstract":"In this thesis, the finite element method (FEM) is applied to the calculation of frequency-dependent series impedances and shunt capacitances of underground power cables. The principal equations describing the quasi-magnetic fields and static electric fields are solved with FEM based on the Galerkin technique. The Js method and the loss-energy method are derived to calculate the impedances of a multiconductor system from its field solution, and the energy method and the surface charge method are derived to calculate the capacitances. With a single-core (SC) coaxial cable, the suitability of quadratic isoparametric elements and high-order simplex elements are studied, and a suitable division scheme is suggested for the auto-mesh program. The conventional FEM with a field truncation boundary is applied to the impedance calculation of buried SC cables. Suitable locations for the field truncation boundary and division schemes in the earth are studied. The results show that rb ≥ 12[symbol omitted] is required to obtain accurate impedances of shallowly buried cables with the conventional FEM. This requires a large solution region in the earth at low frequencies. A new technique based on the perturbation concept is proposed to reduce the solution region in the earth. Comparisons between the results from the conventional FEM and from the proposed technique with a significantly reduced solution region in the earth show good agreement. In the case studies, the FEM is applied to the parameter calculation of multiphase SC cables, PT cables, sector-shaped cables, and stranded conductors. The numerical results are compared with those from analytical formulas.","abstract_html":"In this thesis, the finite element method (FEM) is applied to the calculation of frequency-dependent series impedances and shunt capacitances of underground power cables. The principal equations describing the quasi-magnetic fields and static electric fields are solved with FEM based on the Galerkin technique. The Js method and the loss-energy method are derived to calculate the impedances of a multiconductor system from its field solution, and the energy method and the surface charge method are derived to calculate the capacitances. With a single-core (SC) coaxial cable, the suitability of quadratic isoparametric elements and high-order simplex elements are studied, and a suitable division scheme is suggested for the auto-mesh program. The conventional FEM with a field truncation boundary is applied to the impedance calculation of buried SC cables. Suitable locations for the field truncation boundary and division schemes in the earth are studied. The results show that rb ≥ 12[symbol omitted] is required to obtain accurate impedances of shallowly buried cables with the conventional FEM. This requires a large solution region in the earth at low frequencies. A new technique based on the perturbation concept is proposed to reduce the solution region in the earth. Comparisons between the results from the conventional FEM and from the proposed technique with a significantly reduced solution region in the earth show good agreement. In the case studies, the FEM is applied to the parameter calculation of multiphase SC cables, PT cables, sector-shaped cables, and stranded conductors. The numerical results are compared with those from analytical formulas.","abstract_has_math":false,"creators":["Yin, Yanan"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-19T14:46:44Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/31119","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/31119","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/31119/1/UBC_1990_A1+Y56.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F31119","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Yin, Yanan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1990"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/31119","http://circle.library.ubc.ca/bitstream/2429/31119/1/UBC_1990_A1+Y56.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this thesis, the finite element method (FEM) is applied to the calculation of frequency-dependent series impedances and shunt capacitances of underground power cables. The principal equations describing the quasi-magnetic fields and static electric fields are solved with FEM based on the Galerkin technique. The Js method and the loss-energy method are derived to calculate the impedances of a multiconductor system from its field solution, and the energy method and the surface charge method are derived to calculate the capacitances. With a single-core (SC) coaxial cable, the suitability of quadratic isoparametric elements and high-order simplex elements are studied, and a suitable division scheme is suggested for the auto-mesh program. The conventional FEM with a field truncation boundary is applied to the impedance calculation of buried SC cables. Suitable locations for the field truncation boundary and division schemes in the earth are studied. The results show that rb ≥ 12[symbol omitted] is required to obtain accurate impedances of shallowly buried cables with the conventional FEM. This requires a large solution region in the earth at low frequencies. A new technique based on the perturbation concept is proposed to reduce the solution region in the earth. Comparisons between the results from the conventional FEM and from the proposed technique with a significantly reduced solution region in the earth show good agreement. In the case studies, the FEM is applied to the parameter calculation of multiphase SC cables, PT cables, sector-shaped cables, and stranded conductors. The numerical results are compared with those from analytical formulas."]},{"key":"dc:format","label":"Dc Format","values":["11864939","application/pdf"]},{"key":"dc:title","label":"Title","values":["Calculation of frequency-dependent parameters of underground power cables with finite element method"]}]}],"canonical_facts":{"dc:creator":["Yin, Yanan"],"dc:date":["1990"],"dc:description":["In this thesis, the finite element method (FEM) is applied to the calculation of frequency-dependent series impedances and shunt capacitances of underground power cables. The principal equations describing the quasi-magnetic fields and static electric fields are solved with FEM based on the Galerkin technique. The Js method and the loss-energy method are derived to calculate the impedances of a multiconductor system from its field solution, and the energy method and the surface charge method are derived to calculate the capacitances. With a single-core (SC) coaxial cable, the suitability of quadratic isoparametric elements and high-order simplex elements are studied, and a suitable division scheme is suggested for the auto-mesh program. The conventional FEM with a field truncation boundary is applied to the impedance calculation of buried SC cables. Suitable locations for the field truncation boundary and division schemes in the earth are studied. The results show that rb ≥ 12[symbol omitted] is required to obtain accurate impedances of shallowly buried cables with the conventional FEM. This requires a large solution region in the earth at low frequencies. A new technique based on the perturbation concept is proposed to reduce the solution region in the earth. Comparisons between the results from the conventional FEM and from the proposed technique with a significantly reduced solution region in the earth show good agreement. In the case studies, the FEM is applied to the parameter calculation of multiphase SC cables, PT cables, sector-shaped cables, and stranded conductors. The numerical results are compared with those from analytical formulas."],"dc:format":["11864939","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/31119","http://circle.library.ubc.ca/bitstream/2429/31119/1/UBC_1990_A1+Y56.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Calculation of frequency-dependent parameters of underground power cables with finite element method"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:46:44Z"}